BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

222 related articles for article (PubMed ID: 6431550)

  • 1. [Reduction of the radiation exposure in photofluorography by using rare earth-based fluorescent screens].
    Schöfer H; Eder H
    Rofo; 1984 Aug; 141(2):223-6. PubMed ID: 6431550
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Intensifier fluorography and full-size radiography (author's transl)].
    Renda F; Sanità Di Toppi G; Di Giandomenico V; Marano P
    Radiol Med; 1981 Mar; 67(3):153-8. PubMed ID: 7268087
    [No Abstract]   [Full Text] [Related]  

  • 3. Radiation dose reduction in panoramic radiography. Orthopantomograph Model OP 3 modified for rare earth intensifying screens.
    Forsgren L; Julin P
    Swed Dent J; 1982; 6(6):225-31. PubMed ID: 6963005
    [No Abstract]   [Full Text] [Related]  

  • 4. [Simultaneous tomography using higher-sensitivity screens].
    Maurer HJ; Goos F
    Rofo; 1985 Feb; 142(2):215-7. PubMed ID: 2983397
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Large-screen image intensifier photofluorography compared with full-size screen-film technique in chest radiography.
    Manninen H; Rytkönen H; Soimakallio S; Terho EO; Hentunen J
    Acta Radiol Diagn (Stockh); 1985; 26(5):525-33. PubMed ID: 4072746
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Exposure reduction and image quality for pantomographic radiography.
    Tyndall DA; Bedsole SM
    Radiol Technol; 1987; 59(1):51-3. PubMed ID: 3659339
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of radiation exposures between conventional and rare-earth screen/film systems.
    Chu WK; Sangster W; Dobry CA
    Health Phys; 1985 Nov; 49(5):958-61. PubMed ID: 4066354
    [No Abstract]   [Full Text] [Related]  

  • 8. [Dosage loads and quality of the image in mammography].
    Kozlov AP; Shishov VA; Telesh LV; Fedorov IuA
    Vestn Rentgenol Radiol; 1986; (3):74-9. PubMed ID: 3750831
    [No Abstract]   [Full Text] [Related]  

  • 9. [Reduction of radiation dosage by the use of newer reinforced rare earth films].
    Hofmann T
    Inf Orthod Kieferorthop; 1987; 19(1):107-10. PubMed ID: 3474210
    [No Abstract]   [Full Text] [Related]  

  • 10. [Image enhancer-television equipment--image quality and dose].
    Larwin K
    Strahlenschutz Forsch Prax; 1986; 27():43-7. PubMed ID: 3705125
    [No Abstract]   [Full Text] [Related]  

  • 11. [Personnel radiation load and a method for determining it during operation of the 12F7 x-ray fluorographic apparatus].
    Chikirdin EG; Frolova AV; Astakhova IV
    Vestn Rentgenol Radiol; 1981; (1):73-6. PubMed ID: 7222450
    [No Abstract]   [Full Text] [Related]  

  • 12. Rare-earth phosphor intensifying screens.
    Hollis KD
    Radiography; 1975 Nov; 41(491):249-51. PubMed ID: 1215457
    [No Abstract]   [Full Text] [Related]  

  • 13. [A urological x-ray study table with a 36-cm x-ray image intensifier].
    Melchior H; Lang G
    Urologe A; 1983 Jan; 22(1):49-55. PubMed ID: 6220504
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Image quality in medium format film technique (fluorography) (author's transl)].
    Maurer HJ
    Rofo; 1979 Jul; 131(1):78-83. PubMed ID: 157937
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Green-sensitive X-ray systems and specific features of working with them].
    Blinov NN; Gorelik FG; Reznik KA
    Med Tekh; 2002; (5):13-5. PubMed ID: 12512275
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Roentgenologic converters for medical radioscopy].
    Gusev EA; Zhuravlev SN; Korolev AI; Kuleshov VK; Lanshakov
    Med Tekh; 1989; (1):3-7. PubMed ID: 2739544
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The design and imaging characteristics of dynamic, solid-state, flat-panel x-ray image detectors for digital fluoroscopy and fluorography.
    Cowen AR; Davies AG; Sivananthan MU
    Clin Radiol; 2008 Oct; 63(10):1073-85. PubMed ID: 18774353
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dose performance evaluation of a charge coupled device and a flat-panel digital fluoroscopy system recently installed in an interventional cardiology laboratory.
    Tsapaki V; Kottou S; Kollaros N; Dafnomili P; Kyriakidis Z; Neofotistou V
    Radiat Prot Dosimetry; 2004; 111(3):297-304. PubMed ID: 15266080
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Multi-image camera for spot radiography at fluoroscopic examinations.
    Hynes DM; Edmonds EW; Krametz KR; Baranoski D; Hughes T
    Radiology; 1980 Jul; 136(1):213-8. PubMed ID: 7384502
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Digital image intensifier radiography--one year's experience with a Polytron system].
    Busch HP; Lehmann KJ; Georgi M
    Rofo; 1989 Sep; 151(3):268-73. PubMed ID: 2552516
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.