These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
105 related articles for article (PubMed ID: 6433738)
1. A report on the use of the new Capiox hollow-fibre membrane oxygenator. Dodson H; Newland P; Pastoriza-Pinol JV; McMillan J; McEgan R Anaesth Intensive Care; 1984 May; 12(2):155-8. PubMed ID: 6433738 [No Abstract] [Full Text] [Related]
2. Clinical comparison of the General Electric-Peirce membrane lung and bubble oxygenator for prolonged cardiopulmonary bypass. Chopra PS; Dufek JH; Kroncke GM; Dacumos GC; Celesia GG; Troner SP; Marshall JR; Jefferson JW; Loring LL; Kahn DR Surgery; 1973 Dec; 74(6):874-9. PubMed ID: 4749631 [No Abstract] [Full Text] [Related]
3. [Studies on the development and clinical application of a silicone hollow-fiber membrane oxygenator]. Ohmori K Nihon Kyobu Geka Gakkai Zasshi; 1984 Oct; 32(10):1783-94. PubMed ID: 6440928 [No Abstract] [Full Text] [Related]
5. Evaluation of Capiox RX25 and Quadrox-i Adult Hollow Fiber Membrane Oxygenators in a Simulated Cardiopulmonary Bypass Circuit. Wang S; Kunselman AR; Ündar A Artif Organs; 2016 May; 40(5):E69-78. PubMed ID: 27168381 [TBL] [Abstract][Full Text] [Related]
6. The Landé-Edwards membrane oxygenator for total cardiopulmonary support in 110 patients during heart surgery. Carlson RG; Landé AJ; Ivey LA; Subramanian VA; Bloch JH; Rogos B; Landis B; Baxter J; Patterson RH; Lillehei CW Surgery; 1972 Dec; 72(6):913-9. PubMed ID: 4539001 [No Abstract] [Full Text] [Related]
7. Evaluation of a new low pressure drop membrane oxygenator. Mieszala J; Pearson B Trans Am Soc Artif Intern Organs; 1982; 28():342-9. PubMed ID: 6819672 [No Abstract] [Full Text] [Related]
8. Development of an outside flow membrane oxygenator using a silicone hollow fiber. Sueda T; Fukunaga S; Mitsui N; Matsuura Y; Sato M; Ishihara Y ASAIO J; 1993; 39(3):M457-60. PubMed ID: 8268578 [TBL] [Abstract][Full Text] [Related]
9. Pulsatile and nonpulsatile extracorporeal circulation using Capiox E terumo oxygenator: a comparison study with Ultrox and Maxima membrane oxygenators. Minami K; Bairaktaris A; Murray E; Weitkemper H; Dramburg W; Körfer R J Cardiovasc Surg (Torino); 1997 Jun; 38(3):227-32. PubMed ID: 9219471 [TBL] [Abstract][Full Text] [Related]
10. Clinical evaluation of nine hollow-fibre membrane oxygenators. Segers PA; Heida JF; de Vries I; Maas C; Boogaart AJ; Eilander S Perfusion; 2001 Mar; 16(2):95-106. PubMed ID: 11334201 [TBL] [Abstract][Full Text] [Related]
11. From pulsating to tubular flow membrane-oxygenator. Birnbaum D; Kaiser M Life Support Syst; 1984; 2(4):281-6. PubMed ID: 6441874 [TBL] [Abstract][Full Text] [Related]
13. Alteration of red cell deformability during extracorporeal bypass: membrane v bubble oxygenator. Hakoshima A; Goto H; Abe K; Benson KT; Moran JF; Arakawa K J Cardiothorac Anesth; 1989 Apr; 3(2):189-92. PubMed ID: 2519944 [TBL] [Abstract][Full Text] [Related]
14. Comparison of hollow-fiber membrane oxygenators in terms of pressure drop of the membranes during normothermic and hypothermic cardiopulmonary bypass in neonates. Undar A; Owens WR; McGarry MC; Surprise DL; Kilpack VD; Mueller MW; McKenzie ED; Fraser CD Perfusion; 2005 May; 20(3):135-8. PubMed ID: 16038384 [TBL] [Abstract][Full Text] [Related]
15. Assessment of oxygen transfer in membrane oxygenators during clinical cardiopulmonary bypass. Clayton RH; Pearson DT; Murray A Clin Phys Physiol Meas; 1992 May; 13(2):167-77. PubMed ID: 1499260 [TBL] [Abstract][Full Text] [Related]
16. The relationship between oxygenator exhaust P(CO2) and arterial P(CO2) during hypothermic cardiopulmonary bypass. Graham JM; Gibbs NM; Weightman WM; Sheminant MR Anaesth Intensive Care; 2005 Aug; 33(4):457-61. PubMed ID: 16119486 [TBL] [Abstract][Full Text] [Related]
17. [Evaluation of the structure and function of a hollow fiber membrane oxygenator]. Masuda M; Tokunaga K; Sakai H; Shiraishi K Nihon Rinsho; 1985 Dec; 43(12):2583-6. PubMed ID: 3938994 [No Abstract] [Full Text] [Related]
18. Evaluation of a membrane oxygenator for clinical cardiopulmonary bypass. Spratt EH; Melrose D; Bellhouse B; Badolato A; Thompson R Trans Am Soc Artif Intern Organs; 1981; 27():285-8. PubMed ID: 6800098 [No Abstract] [Full Text] [Related]
19. The new advanced membrane gas exchanger. Berdajs DA; de Stefano E; Delay D; Ferrari E; Horisberger J; Ditmar Q; von Segesser LK Interact Cardiovasc Thorac Surg; 2011 Dec; 13(6):591-6. PubMed ID: 21835847 [TBL] [Abstract][Full Text] [Related]
20. Biocompatibility of a heparin-bonded membrane oxygenator (Carmeda MAXIMA) during the first 90 minutes of cardiopulmonary bypass: clinical comparison with the conventional system. Shigemitsu O; Hadama T; Takasaki H; Mori Y; Kimura T; Miyamoto S; Sako H; Soeda T; Kawawaki Y; Uchida Y Artif Organs; 1994 Dec; 18(12):936-41. PubMed ID: 7887832 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]