These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

93 related articles for article (PubMed ID: 6440928)

  • 1. [Studies on the development and clinical application of a silicone hollow-fiber membrane oxygenator].
    Ohmori K
    Nihon Kyobu Geka Gakkai Zasshi; 1984 Oct; 32(10):1783-94. PubMed ID: 6440928
    [No Abstract]   [Full Text] [Related]  

  • 2. [Basic study of silicone hollow fiber membrane oxygenator (report No. 4) (author's transl)].
    Nakajima T; Suzuki Y; Ogawa K
    Josai Shika Daigaku Kiyo; 1978; 7(2):287-90. PubMed ID: 292500
    [No Abstract]   [Full Text] [Related]  

  • 3. Evaluation of a new low pressure drop membrane oxygenator.
    Mieszala J; Pearson B
    Trans Am Soc Artif Intern Organs; 1982; 28():342-9. PubMed ID: 6819672
    [No Abstract]   [Full Text] [Related]  

  • 4. [Development of the hollow fiber oxygenator and its clinical application (author's transl)].
    Tsuji T; Suma K; Takeuchi Y; Inoue K; Shiroma K
    Iyodenshi To Seitai Kogaku; 1980 Aug; 18(4):264-5. PubMed ID: 6783773
    [No Abstract]   [Full Text] [Related]  

  • 5. [Evaluation of the structure and function of a hollow fiber membrane oxygenator].
    Masuda M; Tokunaga K; Sakai H; Shiraishi K
    Nihon Rinsho; 1985 Dec; 43(12):2583-6. PubMed ID: 3938994
    [No Abstract]   [Full Text] [Related]  

  • 6. Evaluation of a membrane oxygenator for clinical cardiopulmonary bypass.
    Spratt EH; Melrose D; Bellhouse B; Badolato A; Thompson R
    Trans Am Soc Artif Intern Organs; 1981; 27():285-8. PubMed ID: 6800098
    [No Abstract]   [Full Text] [Related]  

  • 7. Silicone-coated polypropylene hollow-fiber oxygenator: experimental evaluation and preliminary clinical use.
    Shimono T; Shomura Y; Hioki I; Shimamoto A; Tenpaku H; Maze Y; Onoda K; Takao M; Shimpo H; Yada I
    Ann Thorac Surg; 1997 Jun; 63(6):1730-6. PubMed ID: 9205175
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical evaluation of a silicone coated hollow fiber oxygenator.
    Shimono T; Shomura Y; Tani K; Shimamoto A; Hioki I; Tokui T; Onoda K; Takao M; Shimpo H; Yada I
    ASAIO J; 1997; 43(5):M735-9. PubMed ID: 9360143
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development of an outside flow membrane oxygenator using a silicone hollow fiber.
    Sueda T; Fukunaga S; Mitsui N; Matsuura Y; Sato M; Ishihara Y
    ASAIO J; 1993; 39(3):M457-60. PubMed ID: 8268578
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development of a new hollow fiber silicone membrane oxygenator for ECMO: the recent progress.
    Kawahito S; Motomura T; Glueck J; Nosé Y
    Ann Thorac Cardiovasc Surg; 2002 Oct; 8(5):268-74. PubMed ID: 12472408
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A report on the use of the new Capiox hollow-fibre membrane oxygenator.
    Dodson H; Newland P; Pastoriza-Pinol JV; McMillan J; McEgan R
    Anaesth Intensive Care; 1984 May; 12(2):155-8. PubMed ID: 6433738
    [No Abstract]   [Full Text] [Related]  

  • 12. Preclinical evaluation of a new hollow fiber silicone membrane oxygenator for pediatric cardiopulmonary bypass: ex-vivo study.
    Kawahito S; Haraguchi S; Maeda T; Motomura T; Takano T; Nonaka K; Linneweber J; Ichikawa S; Kawamura M; Ishitoya H; Glueck J; Sato K; Nosé Y
    Ann Thorac Cardiovasc Surg; 2002 Feb; 8(1):7-11. PubMed ID: 11916436
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Novel concept for pure diffusive capillary membrane oxygenators: silicone hollow sphere (SiHSp) fibers.
    Khachab A; Tabesh H; Kashefi A; Mottaghy K
    ASAIO J; 2013; 59(2):162-8. PubMed ID: 23438780
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Experimental evaluation of a newly developed ultrathin silicone layer coated hollow fiber oxygenator.
    Shimono T; Shomura Y; Tahara K; Hioki I; Tenpaku H; Maze Y; Hirano R; Shimpo H; Shionoya Y; Yokoyama A; Morikan T; Yada I
    ASAIO J; 1996; 42(5):M451-4. PubMed ID: 8944922
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fate of indium 111-labeled platelets during cardiopulmonary bypass performed with membrane and bubble oxygenators.
    Peterson KA; Dewanjee MK; Kaye MP
    J Thorac Cardiovasc Surg; 1982 Jul; 84(1):39-43. PubMed ID: 7087539
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [An experimental study of a newly developed silicone coated membrane oxygenator].
    Iida M
    Nihon Kyobu Geka Gakkai Zasshi; 1997 May; 45(5):700-10. PubMed ID: 9170861
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Feasibility of a new hollow fiber silicone membrane oxygenator for long-term ECMO application.
    Kawahito S; Maeda T; Motomura T; Takano T; Nonaka K; Linneweber J; Ichikawa S; Ishitoya H; Hanazaki K; Glueck J; Sato K; Nosé Y
    J Med Invest; 2002 Aug; 49(3-4):156-62. PubMed ID: 12323005
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Deleterious effects of cardiopulmonary bypass. A prospective study of bubble versus membrane oxygenation.
    van Oeveren W; Kazatchkine MD; Descamps-Latscha B; Maillet F; Fischer E; Carpentier A; Wildevuur CR
    J Thorac Cardiovasc Surg; 1985 Jun; 89(6):888-99. PubMed ID: 3158783
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development of a membrane oxygenator for ECMO using a novel fine silicone hollow fiber.
    Funakubo A; Higami T; Sakuma I; Fukui Y; Kawamura T; Sato K; Sueoka A; Nosé Y
    ASAIO J; 1996; 42(5):M837-40. PubMed ID: 8945001
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cardiopulmonary bypass without systemic heparinization. Performance of heparin-coated oxygenators in comparison with classic membrane and bubble oxygenators.
    von Segesser LK; Turina M
    J Thorac Cardiovasc Surg; 1989 Sep; 98(3):386-96. PubMed ID: 2770320
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.