These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 6456642)

  • 21. Angiographic methods for blood flow measurements.
    Yerushalmi S; Itzchak Y
    Med Prog Technol; 1976; 4(3):107-15. PubMed ID: 798120
    [TBL] [Abstract][Full Text] [Related]  

  • 22. In vivo validation of a thermodilution method to determine regional left ventricular blood flow in patients with coronary disease.
    Pepine CJ; Mehta J; Webster WW; Nichols WW
    Circulation; 1978 Nov; 58(5):795-802. PubMed ID: 151608
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A comparison of two methods to measure coronary flow reserve in the setting of coronary angioplasty: intracoronary blood flow velocity measurements with a Doppler catheter, and digital subtraction cineangiography.
    Serruys PW; Zijlstra F; Laarman GJ; Reiber HH; Beatt K; Roelandt J
    Eur Heart J; 1989 Aug; 10(8):725-36. PubMed ID: 2529120
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Regional distribution of cardiac output: normal values in man determined by video dilution technique.
    Lantz BM; Foerster JM; Link DP; Holcroft JW
    AJR Am J Roentgenol; 1981 Nov; 137(5):903-7. PubMed ID: 7027775
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Value and limitations of computer analysis of digital subtraction angiography in the assessment of coronary flow reserve.
    Nissen SE; Elion JL; Booth DC; Evans J; DeMaria AN
    Circulation; 1986 Mar; 73(3):562-71. PubMed ID: 3948361
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Validation of the saline-dilution method for measuring cardiac output by simultaneous measurement with a perivascular electromagnetic flowprobe.
    Voorhees WD; Bourland JD; Lamp ML; Mullikin JC; Geddes LA
    Med Instrum; 1985; 19(1):34-7. PubMed ID: 3157857
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Assessment of peripheral blood flow in man by video dilution technique: a preliminary report.
    Link DP; Foerster JM; Lantz BM; Holcroft JW
    Invest Radiol; 1981; 16(4):298-304. PubMed ID: 7275542
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Experimental basis of a new method of determination of coronary blood flow with the aid of electromagnetic flowmeter].
    Portnoĭ VF; Dvortsin GF
    Kardiologiia; 1976 May; 16(5):118-23. PubMed ID: 133265
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Alterations of phasic coronary artery flow velocity in humans during percutaneous coronary angioplasty.
    Segal J; Kern MJ; Scott NA; King SB; Doucette JW; Heuser RR; Ofili E; Siegel R
    J Am Coll Cardiol; 1992 Aug; 20(2):276-86. PubMed ID: 1386088
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Digital angiographic impulse response analysis of regional myocardial perfusion. Detection of autoregulatory changes in nonstenotic coronary arteries induced by collateral flow to adjacent stenotic arteries.
    Schühlen H; Eigler NL; Whiting JS
    Circulation; 1994 Mar; 89(3):1004-12. PubMed ID: 8124785
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A comparison of xenon-133 clearance with electromagnetic flowmeters and an indicator dilution method for the measurement of liver blood flow.
    Thorne J; Bennett R; Shields R; Johnson J; Taylor I
    Br J Surg; 1979 Jun; 66(6):385-8. PubMed ID: 157180
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Coronary flow reserve and stenosis as the determinant of exercise capacity in patients with stable effort angina].
    Handa S; Wainai Y; Tani M; Abe S; Yoshikawa T; Negishi K; Asakura Y; Ishikawa S
    Kokyu To Junkan; 1991 Sep; 39(9):917-23. PubMed ID: 1749870
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Angiographic determination of splanchnic blood flow.
    Lantz BM; Link DP; Foerster JM; Holcroft JW
    Acta Radiol Diagn (Stockh); 1980; 21(1):3-10. PubMed ID: 6445675
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Distribution of maximum coronary blood flow in the left ventricular wall of anesthetized dogs.
    Bagger H
    Acta Physiol Scand; 1978 Sep; 104(1):48-60. PubMed ID: 151482
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Coronary blood flow velocity during percutaneous transluminal coronary angioplasty as a guide for assessment of the functional result.
    Serruys PW; Juillière Y; Zijlstra F; Beatt KJ; De Feyter PJ; Suryapranata H; Van Den Brand M; Roelandt J
    Am J Cardiol; 1988 Feb; 61(4):253-9. PubMed ID: 2963517
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Maximal myocardial perfusion by videodensitometry in the assessment of the early and late results of coronary angioplasty: relationship with coronary artery measurements and left ventricular function at rest.
    Vassanelli C; Menegatti G; Molinari J; Zanotto G; Zanolla L; Loschiavo I; Zardini P
    Cathet Cardiovasc Diagn; 1995 Apr; 34(4):301-10; discussion 311-2. PubMed ID: 7621539
    [TBL] [Abstract][Full Text] [Related]  

  • 37. 3D-reconstruction of coronary arteries in view of flow measurement.
    Guggenheim N; Chappuis F; Suilen C; Doriot PA; Dorsaz PA; Descouts P; Rutishauser W
    Int J Card Imaging; 1992; 8(4):265-72. PubMed ID: 1464726
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Videodensitometric system for measurement of vessel blood flow, particularly in the coronary arteries, in man.
    Smith HC; Sturm RE; Wood EH
    Am J Cardiol; 1973 Aug; 32(2):144-50. PubMed ID: 4578631
    [No Abstract]   [Full Text] [Related]  

  • 39. [Normalization of myocardial perfusion reserve after coronary stent implantation in comparison with balloon angioplasty alone].
    Haude M; Caspari G; Baumgart D; Eick B; Liu F; Brennecke R; Meyer J; Erbel R
    Z Kardiol; 1996 Apr; 85(4):260-72. PubMed ID: 8693769
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Total coronary arterial occlusion: real or apparent?
    Seth A; Perry RA; Shiu MF
    Int J Cardiol; 1989 Nov; 25(2):235-7. PubMed ID: 2807612
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.