81 related articles for article (PubMed ID: 6460376)
1. Promising results with a new textured surface intrathoracic variable volume device for LVAS.
Snow J; Harasaki H; Kasick J; Whalen R; Kiraly R; Nosé Y
Trans Am Soc Artif Intern Organs; 1981; 27():485-9. PubMed ID: 6460376
[TBL] [Abstract][Full Text] [Related]
2. Volume compensation for left ventricle assist systems (LVAS): 18 month in vivo evaluation.
Snow J; Harasaki H; Kasick J; Whalen R; Kiraly R; Nosé Y
Trans Am Soc Artif Intern Organs; 1982; 28():539-42. PubMed ID: 7164296
[TBL] [Abstract][Full Text] [Related]
3. Improved textured surfaces for implantable prostheses.
Whalen RL
ASAIO Trans; 1988; 34(3):887-92. PubMed ID: 3196614
[TBL] [Abstract][Full Text] [Related]
4. Biocompatibility tests of components of an implantable cardiac assist device.
von Recum AF; Imamura H; Freed PS; Kantrowitz A; Chen ST; Ekstrom ME; Baechler CA; Barnhart MI
J Biomed Mater Res; 1978 Sep; 12(5):743-65. PubMed ID: 151687
[TBL] [Abstract][Full Text] [Related]
5. Oxidized orlon as a blood interface.
Ross JN; Wright JT; Eskin S; Von Koch L; Normann NA
J Biomed Mater Res; 1976 Jul; 10(4):583-94. PubMed ID: 133112
[TBL] [Abstract][Full Text] [Related]
6. Development of seamless tri-leaflet valves.
Russell FB; Lederman DM; Singh PI; Cumming RD; Morgan RA; Levine FH; Austen WG; Buckley MJ
Trans Am Soc Artif Intern Organs; 1980; 26():66-71. PubMed ID: 7245562
[TBL] [Abstract][Full Text] [Related]
7. Use of a composite biomer/butyl rubber/biomer material to prevent transdiaphragmatic water permeation during long-term, electrically-actuated left ventricular assist device (LVAD) pumping.
McGee MG; Szycher M; Turner SA; Clay W; Trono R; Davis GL; Norman JC
Trans Am Soc Artif Intern Organs; 1980; 26():299-303. PubMed ID: 7245502
[No Abstract] [Full Text] [Related]
8. Long-term in vivo testing of an auxiliary ventricle.
Kiso I; Schraut W; Wajszczuk W; Moskowitz MS; Freed P; Kantrowitz A
Trans Am Soc Artif Intern Organs; 1974; 20 B():637-42. PubMed ID: 4281131
[No Abstract] [Full Text] [Related]
9. Thrombus generation within the artificial heart.
Olsen DB; Unger F; Oster H; Lawson J; Kessler T; Kolff J; Kolff WJ
J Thorac Cardiovasc Surg; 1975 Aug; 70(2):248-55. PubMed ID: 125371
[TBL] [Abstract][Full Text] [Related]
10. The characterization of intima development in left ventricular assist device (LVAD) and total artificial heart (TAH).
Picha G; Helmus M; Barenberg S; Gibbons D; Martin R; Nosé Y
Trans Am Soc Artif Intern Organs; 1976; 22():554-69. PubMed ID: 133497
[TBL] [Abstract][Full Text] [Related]
11. Molecular impact surface textured implants (MISTI) alter beneficially breast capsule formation at 36 months.
Ersek RA
J Long Term Eff Med Implants; 1991; 1(2):155-69. PubMed ID: 10171111
[TBL] [Abstract][Full Text] [Related]
12. Neointimas cultured in vitro for circulatory assistors. 3. Evaluation of antithrombogenic properties.
Adachi M; Suzuki M; Ross JN; Wieting DW; Kennedy JH; De Bakey ME
J Thorac Cardiovasc Surg; 1973 May; 65(5):778-85. PubMed ID: 4266769
[No Abstract] [Full Text] [Related]
13. Cartilaginous metaplasia in the capsule of a Dacron-backed silicone gel breast prosthesis.
Kamel M; Fornasier VL; Peters W
Ann Plast Surg; 1999 Feb; 42(2):202-6. PubMed ID: 10029488
[TBL] [Abstract][Full Text] [Related]
14. Integrally textured polymeric surfaces for permanently implantable cardiac assist devices.
Szycher M; Poirier V; Bernhard WF; Franzblau C; Haudenschild CC; Toselli P
Trans Am Soc Artif Intern Organs; 1980; 26():493-7. PubMed ID: 7245538
[No Abstract] [Full Text] [Related]
15. Quantitative bacterial analysis of porous, fabric, and smooth non-blood contacting implant surfaces and their tissue interfaces in a 169 day pneumatic total artificial heart animal recipient.
Seare WJ; Pantalos GM; Burns GL; Burt WR; Olsen DB
ASAIO J; 1993; 39(3):M668-74. PubMed ID: 8268622
[TBL] [Abstract][Full Text] [Related]
16. Development of skin interfacing cannula.
Hall CW; Adams LM; Ghidoni JJ
Trans Am Soc Artif Intern Organs; 1975; 21():281-8. PubMed ID: 124976
[TBL] [Abstract][Full Text] [Related]
17. Velour-lined silicone rubber as an artificial bladder material.
Stanley TH; Lattimer JK
J Biomed Mater Res; 1972 Nov; 6(6):533-43. PubMed ID: 4264653
[No Abstract] [Full Text] [Related]
18. Effect of a fascial tissue interface on silicone implant capsule formation--a preliminary experimental study.
Uzunismail A; Perk C; Findik H; Beyhan G; Dincler M
J Plast Reconstr Aesthet Surg; 2008 Oct; 61(10):1199-204. PubMed ID: 17761464
[TBL] [Abstract][Full Text] [Related]
19. Development of compliance chamber diaphragms with reduced permeability.
McMillin CR; Fishback T; Harper T; Mussivand T; Kiraly R; Smith W; Navarro R; Nosè Y
J Biomed Mater Res; 1989 Apr; 23(A1 Suppl):117-28. PubMed ID: 2524498
[TBL] [Abstract][Full Text] [Related]
20. Development of blood compatible elastomers. II. Performance of Avcothane blood contact surfaces in experimental animal implantations.
Nyilas E
J Biomed Mater Res; 1972; 6(4):97-127. PubMed ID: 5045267
[No Abstract] [Full Text] [Related]
[Next] [New Search]