These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

704 related articles for article (PubMed ID: 6461352)

  • 21. Dislocated intrauterine devices: clinical presentations, diagnosis and management.
    Tabatabaei F; Masoumzadeh M
    Eur J Contracept Reprod Health Care; 2021 Apr; 26(2):160-166. PubMed ID: 33555216
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Laparoscopic removal of IUD situated outside the uterus].
    Makarov VI; Sotnichenko BA; Belikov VA
    Akush Ginekol (Mosk); 1989 Oct; (10):64-5. PubMed ID: 2533464
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Laparoscopic removal of translocated intrauterine contraceptive devices.
    Gupta I; Sawhney H; Mahajan U
    Aust N Z J Obstet Gynaecol; 1989 Aug; 29(3 Pt 2):352-5. PubMed ID: 2533496
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Perforated intraperitoneal intrauterine contraceptive devices: diagnosis, management, and clinical outcomes.
    Kho KA; Chamsy DJ
    J Minim Invasive Gynecol; 2014; 21(4):596-601. PubMed ID: 24462588
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Management of the missing intrauterine contraceptive device: report of a case.
    Gorsline JC; Osborne NG
    Am J Obstet Gynecol; 1985 Sep; 153(2):228-9. PubMed ID: 3898848
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Removal from the abdominal cavity of an intrauterine device by culdoscopy].
    Acosta Bendek E
    Rev Colomb Obstet Ginecol; 1977; 28(2):85-8. PubMed ID: 565069
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The missing forgotten intrauterine contraceptive device.
    Gruber A; Rabinerson D; Kaplan B; Pardo J; Neri A
    Contraception; 1996 Aug; 54(2):117-9. PubMed ID: 8842589
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Levonorgestrel-Releasing Intrauterine Contraceptive Device in the Peritoneal Cavity: A Report of Two Cases.
    Starič KD; Taneska P; Zore A; Lukanović A; Kobal B; Cvjetićanin B; Jakopič K
    J Reprod Med; 2017; 62(3-4):215-17. PubMed ID: 30230800
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Retrieval of lost Copper-T from the rectum.
    Banerjee N; Kriplani A; Roy KK; Bal S; Takkar D
    Eur J Obstet Gynecol Reprod Biol; 1998 Aug; 79(2):211-2. PubMed ID: 9720843
    [TBL] [Abstract][Full Text] [Related]  

  • 30. An intra-uterine device snapped at the thread insertion.
    Griffiths M
    J Obstet Gynaecol (Lahore); 1989 Jan; 9(3):256-7. PubMed ID: 12282926
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Laparoscopic surgery of an intraperitoneal intrauterine device].
    Ferchiou M; Zhioua F; Hasnaoui M; Sghaier S; Jedoui A; Meriah S
    Rev Fr Gynecol Obstet; 1995 Oct; 90(10):409-11. PubMed ID: 8539506
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Randomised comparative study in 217 women of three disposable plastic IUCD thread retrievers.
    Bounds W; Hutt S; Kubba A; Cooper K; Guillebaud J; Newman GB
    Br J Obstet Gynaecol; 1992 Nov; 99(11):915-9. PubMed ID: 1450143
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Complications associated with the unsuspected presence of intrauterine contraceptive devices.
    Porges RF
    Am J Obstet Gynecol; 1973 Jun; 116(4):579-80. PubMed ID: 4709493
    [TBL] [Abstract][Full Text] [Related]  

  • 34. The role of multimodality radiological imaging in extrauterine misplaced IUCD: A case report.
    Badu-Peprah A; Adu-Bredu TK; Adu-Takyi C
    Afr J Reprod Health; 2020 Dec; 24(4):213-217. PubMed ID: 34077085
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Ultrasonographic evaluation of uterine perforation by an intrauterine device.
    Degesys GE; Panella JS; Moyle J; Rochester D
    J Ultrasound Med; 1982; 1(9):375. PubMed ID: 6152961
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Late uterine perforation with an anchored IUD, the Gynefix: a case report.
    Vekemans M; Verougstraete A
    Contraception; 1999 Jul; 60(1):55-6. PubMed ID: 10549454
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Migration of an intrauterine contraceptive device to the sigmoid colon: a case report.
    Nceboz US; Ozçakir HT; Uyar Y; Cağlar H
    Eur J Contracept Reprod Health Care; 2003 Dec; 8(4):229-32. PubMed ID: 15006271
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Laparoscopic removal of extra-uterine Lippes loop.
    Ladipo OA
    J Natl Med Assoc; 1980 Jul; 72(7):701-2. PubMed ID: 6446609
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Intra-uterine device appendicitis.
    Chang TC; Eden JA
    J Obstet Gynaecol (Lahore); 1989 Jan; 9(3):257-8. PubMed ID: 12282927
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Intrauterine contraceptive devices. Complications associated with their use.
    Nagel TC
    Postgrad Med; 1983 Mar; 73(3):155-64. PubMed ID: 6828391
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 36.