These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 6465492)

  • 1. The cerebral function analysing monitor. Initial clinical experience, application and further development.
    Maynard DE; Jenkinson JL
    Anaesthesia; 1984 Jul; 39(7):678-90. PubMed ID: 6465492
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The cerebral function analysing monitor (CFAM). A new microprocessor-based device for the on-line analysis of the EEG and evoked potentials.
    Sebel PS; Maynard DE; Major E; Frank M
    Br J Anaesth; 1983 Dec; 55(12):1265-70. PubMed ID: 6652016
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effect of halothane on cerebral electrical activity. An assessment using the cerebral function analysing monitoring (CFAM).
    Wark KJ; Sebel PS; Verghese C; Maynard DE; Evans SJ
    Anaesthesia; 1986 Apr; 41(4):390-4. PubMed ID: 3706687
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Monitoring of cerebral function. Limits and values].
    Roujas F; Gaillard M
    Agressologie; 1989; 30(11-12):597-9. PubMed ID: 2631596
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Status epilepticus: clinical experience with two special devices for continuous cerebral monitoring.
    Altafullah I; Asaikar S; Torres F
    Acta Neurol Scand; 1991 Nov; 84(5):374-81. PubMed ID: 1776384
    [TBL] [Abstract][Full Text] [Related]  

  • 6. EEG fitting: a new method for numerical analysis of EEG.
    Gaillard JM
    Neuropsychobiology; 1987; 17(1-2):9-14. PubMed ID: 3627394
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Continuous EEG and evoked potential monitoring in the neuroscience intensive care unit.
    Jordan KG
    J Clin Neurophysiol; 1993 Oct; 10(4):445-75. PubMed ID: 8308143
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cortical neurons and networks are dormant but fully responsive during isoelectric brain state.
    Altwegg-Boussac T; Schramm AE; Ballestero J; Grosselin F; Chavez M; Lecas S; Baulac M; Naccache L; Demeret S; Navarro V; Mahon S; Charpier S
    Brain; 2017 Sep; 140(9):2381-2398. PubMed ID: 29050394
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A microcontroller-based fast evoked potentials recorder.
    Ionescu VL
    Biomed Tech (Berl); 1998; 43 Suppl 3():83-6. PubMed ID: 11776229
    [No Abstract]   [Full Text] [Related]  

  • 10. Development of the CFM: the Cerebral Function Analysing Monitor (CFAM).
    Maynard DE
    Ann Anesthesiol Fr; 1979; 20(3):253-5. PubMed ID: 40483
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cerebral function analysis during deep hypothermia and total circulatory arrest in infant lambs.
    Azariades M; Firmin RK; Lincoln C; Lennox SC
    Thorac Cardiovasc Surg; 1988 Jun; 36(3):133-6. PubMed ID: 3212768
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The usefulness of EEG, exogenous evoked potentials, and cognitive evoked potentials in the acute stage of post-anoxic and post-traumatic coma.
    Guérit JM
    Acta Neurol Belg; 2000 Dec; 100(4):229-36. PubMed ID: 11233678
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Simultaneous continuous EEG evoked potential monitoring using a personal computer].
    Maresch H; Steller E; Litscher G; Thaller P; Pfurtscheller G
    Biomed Tech (Berl); 1990; 35 Suppl 2():90-1. PubMed ID: 2224041
    [No Abstract]   [Full Text] [Related]  

  • 14. High-density electroencephalogram monitoring in the neonate.
    Fifer WP; Grieve PG; Grose-Fifer J; Isler JR; Byrd D
    Clin Perinatol; 2006 Sep; 33(3):679-91, vii. PubMed ID: 16950319
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fundamentals and applications of quantified electrophysiology.
    Zappulla RA
    Ann N Y Acad Sci; 1991; 620():1-21. PubMed ID: 2035935
    [No Abstract]   [Full Text] [Related]  

  • 16. [Use of the Cerebral Function Monitor in general anesthesia].
    Radiguet de la Bastaïe P; Gourves J
    Ann Anesthesiol Fr; 1979; 20(3):187-93. PubMed ID: 40472
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cerebral monitoring in the operating room and the intensive care unit - an introductory for the clinician and a guide for the novice wanting to open a window to the brain. Part II: Sensory-evoked potentials (SSEP, AEP, VEP).
    Freye E
    J Clin Monit Comput; 2005 Apr; 19(1-2):77-168. PubMed ID: 16167223
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The cerebral function analysing monitor in paediatric medical intensive care: applications and limitations.
    Tasker RC; Boyd SG; Harden A; Matthew DJ
    Intensive Care Med; 1990; 16(1):60-8. PubMed ID: 2312908
    [TBL] [Abstract][Full Text] [Related]  

  • 19. EEG processing by the Cerebral Function Monitor (CFM).
    Maynard DE
    Ann Anesthesiol Fr; 1979; 20(3):170-4. PubMed ID: 40470
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Use and significance of the Cerebral Function Monitor in anesthesia during heart surgery].
    Matkó I; Boros M; Kovács G
    Orv Hetil; 1981 Aug; 122(33):2007-11. PubMed ID: 7312335
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 7.