These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
109 related articles for article (PubMed ID: 6477108)
1. A clinical technique for prevention of spasm and preservation of endothelium in saphenous vein grafts. LoGerfo FW; Haudenschild CC; Quist WC Arch Surg; 1984 Oct; 119(10):1212-4. PubMed ID: 6477108 [TBL] [Abstract][Full Text] [Related]
2. An improved technique for preservation of endothelial morphology in vein grafts. LoGerfo FW; Quist WC; Crawshaw HM; Haudenschild C Surgery; 1981 Dec; 90(6):1015-24. PubMed ID: 7313936 [TBL] [Abstract][Full Text] [Related]
3. Optimal techniques for harvesting and preparation of reversed autogenous vein grafts for use as arterial substitutes: a review. Adcock OT; Adcock GL; Wheeler JR; Gregory RT; Snyder SO; Gayle RG Surgery; 1984 Nov; 96(5):886-94. PubMed ID: 6387991 [TBL] [Abstract][Full Text] [Related]
4. Early changes in venous arterial autografts: a scanning electron microscope study. Shand JE; Richardson M; Belbeck LW; Julian J; Gunstensen J Can J Surg; 1983 Mar; 26(2):149-53. PubMed ID: 6825005 [TBL] [Abstract][Full Text] [Related]
5. The influence of harvesting technique on endothelial preservation in saphenous veins. Dries D; Mohammad SF; Woodward SC; Nelson RM J Surg Res; 1992 Mar; 52(3):219-25. PubMed ID: 1538597 [TBL] [Abstract][Full Text] [Related]
6. Papaverine solution improves preservation of saphenous vein grafts used during cardiac surgery. Kocailik A; Basaran M; Ugurlucan M; Ozbek C; Kafali E; Yerebakan C; Selimoglu O; Banach M; Ucak A; Ogus TN; Us M Acta Cardiol; 2008 Aug; 63(4):445-9. PubMed ID: 18795581 [TBL] [Abstract][Full Text] [Related]
7. Arterialization of reversed autogenous vein grafts: quantitative light and electron microscopy of canine jugular vein grafts harvested and implanted by standard or improved techniques. Adcock GD; Adcock OT; Wheeler JR; Gregory RT; Snyder SO; Gayle RG; Trivedi AN J Vasc Surg; 1987 Sep; 6(3):283-95. PubMed ID: 3625885 [TBL] [Abstract][Full Text] [Related]
8. The factors influencing early patency of coronary artery bypass vein grafts: correlation of angiographic and ultrastructural findings. Catinella FP; Cunningham JN; Srungaram RK; Baumann FG; Nathan IM; Glassman EA; Knopp EA; Spencer FC J Thorac Cardiovasc Surg; 1982 May; 83(5):686-700. PubMed ID: 6978974 [TBL] [Abstract][Full Text] [Related]
9. Improved preservation of saphenous vein grafts by the use of glyceryl trinitrate-verapamil solution during harvesting. Roubos N; Rosenfeldt FL; Richards SM; Conyers RA; Davis BB Circulation; 1995 Nov; 92(9 Suppl):II31-6. PubMed ID: 7586430 [TBL] [Abstract][Full Text] [Related]
10. Biochemical and ultrastructural integrity of the saphenous vein conduit during coronary artery bypass grafting. Preliminary results of the effect of papaverine. Roberts AJ; Hay DA; Mehta JL; Mehta P; Roy L; Faro RS; Knauf DG; Alexander JA J Thorac Cardiovasc Surg; 1984 Jul; 88(1):39-48. PubMed ID: 6376960 [TBL] [Abstract][Full Text] [Related]
11. University of Wisconsin solution and human saphenous vein graft preservation: preliminary anatomic report. Santoli E; Di Mattia D; Boldorini R; Mingoli A; Tosoni A; Santoli C Eur J Cardiothorac Surg; 1993; 7(10):548-52. PubMed ID: 8267997 [TBL] [Abstract][Full Text] [Related]
12. Harvesting and protection of the saphenous vein associated with early delivery of blood cardioplegia in coronary artery bypass graft surgery. Feikes HL; Roberts AJ Am Heart J; 1982 Aug; 104(2 Pt 1):329-32. PubMed ID: 6980583 [No Abstract] [Full Text] [Related]
13. [Use of heparinized autologous blood for intraoperative rinsing and storage of vascular grafts]. Kimura H; Hosoda K; Kohmura E No Shinkei Geka; 2015 Feb; 43(2):109-15. PubMed ID: 25672551 [TBL] [Abstract][Full Text] [Related]
14. Optimal preparation techniques for human saphenous vein grafts. Gundry SR; Jones M; Ishihara T; Ferrans VJ Surgery; 1980 Dec; 88(6):785-94. PubMed ID: 7444762 [TBL] [Abstract][Full Text] [Related]
15. Improved patency in vein grafts harvested with surrounding tissue: results of a randomized study using three harvesting techniques. Souza DS; Dashwood MR; Tsui JC; Filbey D; Bodin L; Johansson B; Borowiec J Ann Thorac Surg; 2002 Apr; 73(4):1189-95. PubMed ID: 11996262 [TBL] [Abstract][Full Text] [Related]
16. Preservation of endothelial vascular function of saphenous vein grafts after long-time storage with a recently developed potassium-chloride and N-acetylhistidine enriched storage solution. Wilbring M; Tugtekin SM; Zatschler B; Ebner A; Reichenspurner H; Kappert U; Matschke K; Deussen A Thorac Cardiovasc Surg; 2013 Dec; 61(8):656-62. PubMed ID: 22791204 [TBL] [Abstract][Full Text] [Related]
17. Neutrophil adherence to activated saphenous vein and mammary endothelium after graft preparation. Schlitt A; Pruefer D; Buerke U; Russ M; Dahm M; Oelert H; Werdan K; Buerke M Ann Thorac Surg; 2006 Apr; 81(4):1262-8. PubMed ID: 16564255 [TBL] [Abstract][Full Text] [Related]
18. Heparinized blood better preserves cellular energy charge and vascular functions of intraoperatively stored saphenous vein grafts in comparison to isotonic sodium-chloride-solution. Wilbring M; Ebner A; Schoenemann K; Knaut M; Tugtekin SM; Zatschler B; Waldow T; Alexiou K; Matschke K; Deussen A Clin Hemorheol Microcirc; 2013 Jan; 55(4):445-55. PubMed ID: 24113503 [TBL] [Abstract][Full Text] [Related]
19. Use of cold cardioplegic solution for vein graft distention and preservation: a light and scanning electron microscopic study. Kurusz M; Christman EW; Derrick JR; Tyers GF; Williams EH Ann Thorac Surg; 1981 Jul; 32(1):68-74. PubMed ID: 6972750 [TBL] [Abstract][Full Text] [Related]
20. Alterations in c-fos expression, cell proliferation and apoptosis in pressure distended human saphenous vein. Galea J; Armstrong J; Francis SE; Cooper G; Crossman DC; Holt CM Cardiovasc Res; 1999 Nov; 44(2):436-48. PubMed ID: 10690320 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]