BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 6477200)

  • 1. Immunologic studies of hollow-fiber dialyzer extracts.
    Butcher BT; Reed MA; O'Neil CE; Leech S; Pearson FC
    Artif Organs; 1984 Aug; 8(3):318-28. PubMed ID: 6477200
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Role of dialyzer contaminants in the allergic epiphenomena of hemodialysis.
    Ward RA; Feldhoff PW; Klein E
    Artif Organs; 1984 Aug; 8(3):338-49. PubMed ID: 6477203
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of chemical analyses of hollow-fiber dialyzer extracts.
    Pearson FC; Bohon J; Lee W; Bruszer G; Sagona M; Dawe R; Jakubowski G; Morrison D; Dinarello C
    Artif Organs; 1984 Aug; 8(3):291-8. PubMed ID: 6383298
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Hollow-fiber dialyzers and their pyrogenicity testing by Limulus amebocyte lysate.
    Henne W; Schulze H; Pelger M; Tretzel J; von Sengbusch G
    Artif Organs; 1984 Aug; 8(3):299-305. PubMed ID: 6477197
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Acute anaphylactoid reactions during hemodialysis in France.
    Forêt M; Kuentz F; Meftahi H; Milongo R; Hachache T; Elsener M; Dechelette E; Cordonnier D
    Artif Organs; 1987 Apr; 11(2):168-72. PubMed ID: 3593044
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Relative importance of membrane Limulus amebocyte lysate-reactive material and ethylene oxide in hypersensitivity reactions.
    Pearson FC
    Contrib Nephrol; 1987; 59():134-44. PubMed ID: 3442983
    [No Abstract]   [Full Text] [Related]  

  • 7. Characterization of Limulus amoebocyte lysate-reactive material from hollow-fiber dialyzers.
    Pearson FC; Bohon J; Lee W; Bruszer G; Sagona M; Jakubowski G; Dawe R; Morrison D; Dinarello C
    Appl Environ Microbiol; 1984 Dec; 48(6):1189-96. PubMed ID: 6517586
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ethylene oxide sensitivity in hemodialysis patients.
    Pearson F; Bruszer G; Lee W; Sagona M; Sargent H; Woods E; Dolovich J; Caruana R
    Artif Organs; 1987 Apr; 11(2):100-3. PubMed ID: 3593040
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Mediation of hypersensitivity reactions during hemodialysis by IgE antibodies against ethylene oxide.
    Lemke HD
    Artif Organs; 1987 Apr; 11(2):104-10. PubMed ID: 3297007
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Plate, coil, and hollow-fiber cuprammonium cellulose dialyzers: discrepancy between incidence of anaphylactic reactions and degree of complement activation.
    Daugirdas JT; Potempa LD; Dinh N; Gandhi VC; Ivanovich PT; Ing TS
    Artif Organs; 1987 Apr; 11(2):140-3. PubMed ID: 3593043
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Immune responses to dialyzer contents by dialysis patients.
    Sherlock JE; Bachvaroff R
    Miner Electrolyte Metab; 1987; 13(6):405-8. PubMed ID: 3121994
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Complement activation during hemodialysis: clinical observations, proposed mechanisms, and theoretical implications.
    Chenoweth DE
    Artif Organs; 1984 Aug; 8(3):281-90. PubMed ID: 6332607
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Anaphylatoxin formation during hemodialysis: effects of different dialyzer membranes.
    Chenoweth DE; Cheung AK; Henderson LW
    Kidney Int; 1983 Dec; 24(6):764-9. PubMed ID: 6609269
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of dialyzer geometry on granulocyte and complement activation.
    Schaefer RM; Heidland A; Hörl WH
    Am J Nephrol; 1987; 7(2):121-6. PubMed ID: 3496792
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Limulus amebocyte lysate reactivity, complement activation, and patients' symptoms. Comparison of dialyzer membranes.
    Moss AH; Hamrick RM; Shen SH
    ASAIO Trans; 1989; 35(4):812-5. PubMed ID: 2611049
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The influence of dialyzer geometry on blood coagulation and biocompatibility.
    Lins LE; Boberg U; Jacobson SH; Kjellstrand C; Ljungberg B; Skröder R
    Clin Nephrol; 1993 Nov; 40(5):281-5. PubMed ID: 8281717
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of dialyzer geometry during hemodialysis with cuprophane membranes.
    Taylor JE; McLaren M; Mactier RA; Henderson IS; Stewart WK; Belch JJ
    Kidney Int; 1992 Aug; 42(2):442-7. PubMed ID: 1405328
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hypersensitivity reaction on first-time exposure to cuprophan hollow fiber dialyzer.
    Key J; Nahmias M; Acchiardo S
    Am J Kidney Dis; 1983 May; 2(6):664-6. PubMed ID: 6846336
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Antibody responses to hemodialysis-related antigens in chronic hemodialysis patients.
    Dolovich J; Evans S; Baurmeister U; Schulze H; Ali M; Shimizu A
    Artif Organs; 1987 Apr; 11(2):93-6. PubMed ID: 3593051
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Plasma levels of main granulocyte components in patients dialyzed with polycarbonate and cuprophan membranes.
    Hörl WH; Riegel W; Schollmeyer P
    Nephron; 1987; 45(4):272-6. PubMed ID: 3035392
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.