118 related articles for article (PubMed ID: 6482369)
1. Use of a gadolinium filter on an X-ray contrast examination. Umezaki N; Toyoshima K; Takada K; Koga T; Kondo Y; Morita S; Yano K; Ohtake H Kurume Med J; 1984; 31(1):15-20. PubMed ID: 6482369 [No Abstract] [Full Text] [Related]
2. Clinical use of a gadolinium filter in pediatric radiography. Johnson MA; Burgess AE Pediatr Radiol; 1981; 10(4):229-32. PubMed ID: 7254920 [TBL] [Abstract][Full Text] [Related]
3. Contrast effects of a gadolinium filter. Burgess AE Med Phys; 1981; 8(2):203-9. PubMed ID: 7322047 [TBL] [Abstract][Full Text] [Related]
4. [Pre-filtration of an x-ray source and the radiation exposure of patients]. Meiler J Rontgenpraxis; 1989 Apr; 42(4):119-23. PubMed ID: 2711262 [No Abstract] [Full Text] [Related]
5. Filter materials for dose reduction in screen-film radiography. Koedooder K; Venema HW Phys Med Biol; 1986 Jun; 31(6):585-600. PubMed ID: 3755830 [TBL] [Abstract][Full Text] [Related]
6. The use of added erbium filtration in intraoral radiography. Ponce AZ; McDavid WD; Langland OE Oral Surg Oral Med Oral Pathol; 1988 Oct; 66(4):513-7. PubMed ID: 3186228 [TBL] [Abstract][Full Text] [Related]
7. Application of added beam filtration to intra-oral radiography. Kapa SF; Tyndall DA; Ouellette TE Dentomaxillofac Radiol; 1990 May; 19(2):67-74. PubMed ID: 2079143 [No Abstract] [Full Text] [Related]
11. Experimental and theoretical x-ray imaging performance comparison of iodine and lanthanide contrast agents. Cardinal HN; Holdsworth DW; Drangova M; Hobbs BB; Fenster A Med Phys; 1993; 20(1):15-31. PubMed ID: 8455493 [TBL] [Abstract][Full Text] [Related]
12. How good is the erbium filter? Howard C Radiogr Today; 1991 Jun; 57(649):22-6. PubMed ID: 1910517 [No Abstract] [Full Text] [Related]
13. Physical measurements of heavy metal filter performance. Burgess AE Med Phys; 1985; 12(2):225-8. PubMed ID: 4000081 [TBL] [Abstract][Full Text] [Related]
14. Use of E-speed film with added filtration. Ponce AZ; McDavid WD; Underhill TE; Morris CR Oral Surg Oral Med Oral Pathol; 1986 Mar; 61(3):297-9. PubMed ID: 3458135 [TBL] [Abstract][Full Text] [Related]
15. The effect of thin K-edge filters on the image quality of D- and E-speed dental film. MacDonald-Jankowski DS; Lawinski CP; Payne M Dentomaxillofac Radiol; 1995 Feb; 24(1):23-9. PubMed ID: 8593903 [TBL] [Abstract][Full Text] [Related]
16. Using compensating filters to reduce radiation dose. Katsuda T; Okazaki M; Kuroda C Radiol Technol; 1996; 68(1):18-22. PubMed ID: 8880967 [TBL] [Abstract][Full Text] [Related]
17. An investigation of X-ray equipment factors influencing patient dose in radiography. Williams JR; Catling MK Br J Radiol; 1998 Nov; 71(851):1192-8. PubMed ID: 10434915 [TBL] [Abstract][Full Text] [Related]