These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 6482539)

  • 1. Effects of multiple scattering and peripheral circulation on arterial oxygen saturation measured with a pulse-type oximeter.
    Shimada Y; Yoshiya I; Oka N; Hamaguri K
    Med Biol Eng Comput; 1984 Sep; 22(5):475-8. PubMed ID: 6482539
    [No Abstract]   [Full Text] [Related]  

  • 2. Evaluation of oesophageal pulse oximetry in patients undergoing cardiothoracic surgery.
    Kyriacou PA; Powell SL; Jones DP; Langford RM
    Anaesthesia; 2003 May; 58(5):422-7. PubMed ID: 12693996
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An in vivo investigation of photoplethysmographic signals and preliminary pulse oximetry estimation from the bowel using a new fiberoptic sensor.
    Hickey M; Samuels N; Randive N; Langford RM; Kyriacou PA
    Anesth Analg; 2011 May; 112(5):1104-9. PubMed ID: 21346164
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pulse oximetry in the oesophagus.
    Kyriacou PA
    Physiol Meas; 2006 Jan; 27(1):R1-35. PubMed ID: 16365505
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Non-invasive measurement of peripheral venous oxygen saturation using a new venous oximetry method: evaluation during bypass in heart surgery.
    Echiadis AS; Crabtree VP; Bence J; Hadjinikolaou L; Alexiou C; Spyt TJ; Hu S
    Physiol Meas; 2007 Aug; 28(8):897-911. PubMed ID: 17664681
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Non-invasive pulse oximetry for the measurement of oxygen saturation in intensive care patients].
    Spiss CK; Mauritz W; Zadrobilek E; Draxler V
    Anaesthesist; 1985 Aug; 34(8):405-8. PubMed ID: 3931497
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Does the estimation of light attenuation in tissue increase the accuracy of reflectance pulse oximetry at low oxygen saturations in vivo?
    Kisch-Wedel H; Bernreuter P; Kemming G; Albert M; Zwissler B
    IEEE Trans Biomed Eng; 2009 Sep; 56(9):2271-9. PubMed ID: 19692303
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Retinal oximetry and systemic arterial oxygen levels.
    Eliasdottir TS
    Acta Ophthalmol; 2018 Nov; 96 Suppl A113():1-44. PubMed ID: 30460761
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pulse Oximetry with Two Infrared Wavelengths without Calibration in Extracted Arterial Blood.
    Yossef Hay O; Cohen M; Nitzan I; Kasirer Y; Shahroor-Karni S; Yitzhaky Y; Engelberg S; Nitzan M
    Sensors (Basel); 2018 Oct; 18(10):. PubMed ID: 30326552
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Proof of concept non-invasive estimation of peripheral venous oxygen saturation.
    Khan M; Pretty CG; Amies AC; Balmer J; Banna HE; Shaw GM; Geoffrey Chase J
    Biomed Eng Online; 2017 May; 16(1):60. PubMed ID: 28526082
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Inaccuracy of pulse oximetry in patients with severe tricuspid regurgitation.
    Stewart KG; Rowbottom SJ
    Anaesthesia; 1991 Aug; 46(8):668-70. PubMed ID: 1887977
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Technical note: Evaluation of a wireless pulse oximeter for measuring arterial oxygen saturation and pulse rate in newborn Holstein Friesian calves.
    Kanz P; Krieger S; Drillich M; Iwersen M
    J Dairy Sci; 2018 Jul; 101(7):6437-6442. PubMed ID: 29705429
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Forehead is as sensitive as finger pulse oximetry during general anesthesia.
    Sugino S; Kanaya N; Mizuuchi M; Nakayama M; Namiki A
    Can J Anaesth; 2004 May; 51(5):432-6. PubMed ID: 15128627
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The OxiMax System. Nellcor's new platform for pulse oximetry.
    Mannheimer PD; Bebout DE
    Minerva Anestesiol; 2002 Apr; 68(4):236-9. PubMed ID: 12024089
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Oxygen Saturation in Dental Pulp of Permanent Teeth: Difference between Children/Adolescents and Adults.
    Stella JP; Barletta FB; Giovanella LB; Grazziotin-Soares R; Tovo MF; Felippe WT; Estrela C
    J Endod; 2015 Sep; 41(9):1445-9. PubMed ID: 26093471
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reflectance pulse oximetry in fetal lambs.
    Dassel AC; Graaff R; Aarnoudse JG; Elstrodt JM; Heida P; Koelink MH; de Mul FF; Greve J
    Pediatr Res; 1992 Mar; 31(3):266-9. PubMed ID: 1561013
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Use of pulse oximetry as screening method for peripheral arterial disease in patients admitted to a general medicine service].
    Alvarez CE; Verdú G; Ena J
    Clin Investig Arterioscler; 2013; 25(1):1-7. PubMed ID: 23522275
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The Nellcor N-101 pulse oximeter. A clinical evaluation in anaesthesia and intensive care.
    Tytler JA; Seeley HF
    Anaesthesia; 1986 Mar; 41(3):302-5. PubMed ID: 3963334
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Does henna impact pulse oximetry results?
    Zolfaghari M; Moradi Majd P; Behesht Aeen F; Mohseni AR; Azimi Ahangari K; Haghani H
    Emerg Med J; 2015 Mar; 32(3):248-9. PubMed ID: 25398238
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pulse oximetry in very low birth weight infants with acute and chronic lung disease.
    Ramanathan R; Durand M; Larrazabal C
    Pediatrics; 1987 Apr; 79(4):612-7. PubMed ID: 2434913
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.