These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

106 related articles for article (PubMed ID: 6483966)

  • 1. Effective energy in diagnostic radiology. A critical review.
    Carlsson GA; Carlsson CA
    Phys Med Biol; 1984 Aug; 29(8):953-8. PubMed ID: 6483966
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Energy imparted to the patient in diagnostic radiology: calculation of conversion factors for determining the energy imparted from measurements of the air collision kerma integrated over beam area.
    Alm Carlsson G; Carlsson CA; Persliden J
    Phys Med Biol; 1984 Nov; 29(11):1329-41. PubMed ID: 6505015
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Computation of energy imparted in diagnostic radiology.
    Gkanatsios NA; Huda W
    Med Phys; 1997 Apr; 24(4):571-9. PubMed ID: 9127310
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Energy imparted to water slabs by photons in the energy range 5-300 keV. Calculations using a Monte Carlo photon transport model.
    Persliden J; Carlsson GA
    Phys Med Biol; 1984 Sep; 29(9):1075-88. PubMed ID: 6483973
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Relations between effective dose equivalent and mean absorbed dose (energy imparted) to patients in diagnostic radiology.
    Carlsson GA; Carlsson CA
    Phys Med Biol; 1986 Aug; 31(8):911-21. PubMed ID: 3763701
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Calculation of the small-angle distribution of scattered photons in diagnostic radiology using a Monte Carlo collision density estimator.
    Persliden J; Carlsson GA
    Med Phys; 1986; 13(1):19-24. PubMed ID: 3951405
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [New units of measure in radiology. Comments on the contribution "New units of measure in radiology" by Gunther Hoppe, Berlin, in volume 26, No. 1, January 1973, Pg. 10].
    Pychlau PJ; Hoppe G
    Rontgenpraxis; 1973 Apr; 26(4):95-7. PubMed ID: 4697589
    [No Abstract]   [Full Text] [Related]  

  • 8. Radiation dose assessment in a 320-detector-row CT scanner used in cardiac imaging.
    Gomà C; Ruiz A; Jornet N; Latorre A; Pallerol RM; Carrasco P; Eudaldo T; Ribas M
    Med Phys; 2011 Mar; 38(3):1473-80. PubMed ID: 21520859
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Quantitative concepts for evaluating the effectiveness of roentgen diagnostic studies--predictive value].
    Stargardt A; Angerstein W; Fuchs R
    Radiol Diagn (Berl); 1984; 25(4):345-52. PubMed ID: 6484142
    [No Abstract]   [Full Text] [Related]  

  • 10. Extension of the range of definition of the practical peak voltage up to 300 kV.
    Kramer HM; Selbach HJ
    Br J Radiol; 2008 Sep; 81(969):693-8. PubMed ID: 18769013
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Generalised use of contrast degradation and contrast improvement factors in diagnostic radiology. Application to vanishing contrast.
    Carlsson GA; Carlsson CA; Nielsen B; Persliden J
    Phys Med Biol; 1986 Jul; 31(7):737-49. PubMed ID: 3749260
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Relationships between energy fluence and energy incident on, emitted by or imparted to a body.
    Carlsson CA
    Phys Med Biol; 1979 Nov; 24(6):1209-15. PubMed ID: 531095
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Selected technical aspects of roentgen diagnostic equipment from the view of quality control requirements].
    Demczuk P; Jankowski J
    Med Pr; 1997; 48(3):293-305. PubMed ID: 9312656
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Parameterized algorithms for quantitative differentials in spectrally equivalent medical diagnostic x-ray beams.
    Okunade AA
    Med Phys; 2005 Jun; 32(6):1785-95. PubMed ID: 16013736
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The measurement of energy imparted to patients during diagnostic x-ray examinations using the Diamentor exposure-area product meter.
    Shrimpton PC; Wall BF; Jones DG; Fisher ES
    Phys Med Biol; 1984 Oct; 29(10):1199-208. PubMed ID: 6494248
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Some properties of photon scattering in water phantoms in diagnostic radiology.
    Chan HP; Doi K
    Med Phys; 1986; 13(6):824-30. PubMed ID: 3796478
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Theory and practice of the determination of the effectiveness of roentgen examinations--a complex analysis toward decreasing the frequency of requests for roentgen diagnosis. 1. Theoretical principles, concept illustration and examples].
    Fuchs R; Liebscher J
    Radiol Diagn (Berl); 1984; 25(3):225-34. PubMed ID: 6484131
    [No Abstract]   [Full Text] [Related]  

  • 18. Calculation of scattering cross sections for increased accuracy in diagnostic radiology. I. Energy broadening of Compton-scattered photons.
    Carlsson GA; Carlsson CA; Berggren KF; Ribberfors R
    Med Phys; 1982; 9(6):868-79. PubMed ID: 7162473
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Tissue-air ratios and scatter-air ratios for diagnostic radiology (1-4 mm Al HVL).
    Harrison RM
    Phys Med Biol; 1983 Jan; 28(1):1-18. PubMed ID: 6828554
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Aluminum equivalence of materials used in diagnostic radiology and its dependence on beam quality.
    Nagel HD
    Phys Med Biol; 1986 Dec; 31(12):1381-99. PubMed ID: 3809240
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.