These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
105 related articles for article (PubMed ID: 6486326)
1. [Loco-regional epidural pressure and differential intracranial pressure: value of monitoring in patients with a unilateral intracerebral lesion]. Roux FX; Raggueneau JL; George B; Dematons C; Goldstein A Agressologie; 1984 May; 25(5):559-61. PubMed ID: 6486326 [No Abstract] [Full Text] [Related]
4. [Epidural measurement of intracranial pressure by a newly-developed pressure transducer (author's transl)]. Ikeyama A; Furuse M; Nagai H; Maeda S; Inagaki H; Igarashi I; Kitano T Iyodenshi To Seitai Kogaku; 1982 Feb; 20(1):1-7. PubMed ID: 7109316 [No Abstract] [Full Text] [Related]
5. Comparison of simultaneous continuous intracranial pressure (ICP) signals from ICP sensors placed within the brain parenchyma and the epidural space. Eide PK Med Eng Phys; 2008 Jan; 30(1):34-40. PubMed ID: 17336574 [TBL] [Abstract][Full Text] [Related]
6. [Monitoring of the intracranial pressure in severely head-injured patients. Survey]. Melon E; Abhay K; Homs JB Agressologie; 1988 Apr; 29(5):333-6. PubMed ID: 3213875 [No Abstract] [Full Text] [Related]
7. [Value of intracranial pressure monitoring during the acute phase of neurosurgical intensive care. Apropos of a case]. Millet A; Escuret E; Roquefeuil B Agressologie; 1984 May; 25(5):563-5. PubMed ID: 6486327 [No Abstract] [Full Text] [Related]
8. Evaluating an ICP epidural catheter. Shepard R; Hotter AN Crit Care Nurse; 1989 Feb; 9(2):74-80. PubMed ID: 2582798 [No Abstract] [Full Text] [Related]
9. [Monitoring of intracranial pressure with an epidural fluid-filled transducer: difficulties with positioning and accuracy of measurements]. Artru F; Jourdan C; Deschamps J; Baffeleuf B; Terrier A; Deleuze R Agressologie; 1988 Apr; 29(5):365-9. PubMed ID: 3213881 [No Abstract] [Full Text] [Related]
10. [Fulminant cases in the lateral type of hypertensive intracerebral hematoma (author's transl)]. Koba T; Yokoyama T; Kaneko M No Shinkei Geka; 1977 Jun; 5(6):559-65. PubMed ID: 917225 [No Abstract] [Full Text] [Related]
11. [Experimental studies of the effect of intracerebral hematoma on cerebral circulation and metabolism (author's transl)]. Suzuki A No To Shinkei; 1980 Feb; 32(2):143-52. PubMed ID: 7370125 [No Abstract] [Full Text] [Related]
12. [One possibility of producing the plateau waves from the observations of two pontine hemorrhage cases (author's transl)]. Hayashi M; Kitano T; Kobayashi H; Munemoto S; Fujii H; Shima T; Yamamoto S No To Shinkei; 1979 Feb; 31(2):169-76. PubMed ID: 426943 [No Abstract] [Full Text] [Related]
13. [Monitoring intracranial pressure in pseudotumor cerebri. Apropos of 2 cases]. Eizaguirre I; García Goicoechea M; García Goicoechia M; Albisu Y; Navajas B; Pérez-Yarza EG An Esp Pediatr; 1982 Jun; 16(6):520-3. PubMed ID: 7125404 [No Abstract] [Full Text] [Related]
14. [Measuring intracranial pressure after trepanation in traumatized patients]. Lopatecki M; Loritz T; Rudigier J Aktuelle Traumatol; 1993 Aug; 23(5):217-22. PubMed ID: 7901974 [TBL] [Abstract][Full Text] [Related]