These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

98 related articles for article (PubMed ID: 6488544)

  • 41. The Hycel-M multichannel analyzer--a model for evaluation.
    Arntsen KW; Deacon AC; Worth HG
    Clin Chem; 1982 Jun; 28(6):1338-43. PubMed ID: 7074942
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Performance and Suitability of Mindray BS480©: A Fully Open Clinical Chemistry Analyzer.
    Dupuy AM; Plawecki M; Bargnoux AS; Badiou S; Delage M; Lotierzo M; Cristol JP
    Ann Clin Lab Sci; 2018 Jul; 48(4):511-516. PubMed ID: 30143495
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Laboratory evaluation of the Beckman Synchron CX3 clinical chemistry analyzer.
    Peake MJ; Pejakovic M; White GH
    Clin Chem; 1988 Feb; 34(2):404-7. PubMed ID: 3124982
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Use of an enzyme standard in the measurement of enzymes in a Clinicon reaction rate analyser.
    Nisbet JA; Owen JA; Pulford FG
    Ann Clin Biochem; 1982 May; 19(3):160-2. PubMed ID: 7092141
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Automation and other recent developments in clinical chemistry.
    Griffiths J
    Am J Clin Pathol; 1992 Oct; 98(4 Suppl 1):S31-4. PubMed ID: 1344702
    [TBL] [Abstract][Full Text] [Related]  

  • 46. [Extinction measuring device EK with flow-through cuvette].
    Fischer J
    Z Med Labortech; 1973; 14(5):309-13. PubMed ID: 4770632
    [No Abstract]   [Full Text] [Related]  

  • 47. [Measurement of concentration of antibiotics. A method and its use].
    Jepsen OB
    Ugeskr Laeger; 1968 Dec; 130(50):2174-8. PubMed ID: 5707939
    [No Abstract]   [Full Text] [Related]  

  • 48. A multichannel continuous-flow analyzer.
    Thiers RE; Bryan J; Oglesby K
    Clin Chem; 1966 Mar; 12(3):120-36. PubMed ID: 5904229
    [No Abstract]   [Full Text] [Related]  

  • 49. Investigation of applicability of a mid-infrared spectroscopic method using an attenuated total reflection accessory and a new near-infrared transmission method for determination of faecal fat.
    Volmer M; Kingma AW; Borsboom PC; Wolthers BG; Kema IP
    Ann Clin Biochem; 2001 May; 38(Pt 3):256-63. PubMed ID: 11392501
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Chasing rainbows. Color reactions of analyses performed on a Siemens Dimension EXL.
    Hooijberg E
    Vet Clin Pathol; 2014 Mar; 43(1):4-5. PubMed ID: 24588572
    [No Abstract]   [Full Text] [Related]  

  • 51. Instrumentation and techniques for therapeutic drug monitoring.
    Dito WR
    Clin Lab Med; 1981 Sep; 1(3):451-66. PubMed ID: 7049525
    [No Abstract]   [Full Text] [Related]  

  • 52. IFCC recommended reference method for the determination of the substance concentration of ionized calcium in undiluted serum, plasma or whole blood.
    Burnett RW; Christiansen TF; Covington AK; Fogh-Andersen N; Külpmann WR; Lewenstam A; Maas AHJ ; Müller-Plathe O; Sachs C; Andersen OS; VanKessel AL; Zijlstra WG;
    Clin Chem Lab Med; 2000 Dec; 38(12):1301-14. PubMed ID: 11205698
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Oxygen equilibrium measurements of human red blood cells.
    Kister J; Wajcman H
    Methods Mol Med; 2003; 82():49-64. PubMed ID: 12669637
    [No Abstract]   [Full Text] [Related]  

  • 54. Determination of total urinary protein by combined gel filtration and automated biuret reaction.
    Doetsch K
    Clin Chem; 1972 Mar; 18(3):296-8. PubMed ID: 5020829
    [No Abstract]   [Full Text] [Related]  

  • 55. An automated assay of urinary alanine aminopeptidase activity.
    Holdt B; Peters E; Nagel HR; Steiner M
    Clin Chem Lab Med; 2008; 46(4):537-40. PubMed ID: 18302530
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Electrodes in clinical chemistry.
    Hirst AD; Stevens JF
    Ann Clin Biochem; 1985 Sep; 22 ( Pt 5)():460-88. PubMed ID: 3904587
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Atomic and molecular absorption theory and practice as applied to clinical chemistry.
    Stevens J; Kilshaw D; Williamson T; Randall J; Sacre M; Walker G
    Med Lab Technol; 1975 Jul; 32(3):183-91. PubMed ID: 1160814
    [No Abstract]   [Full Text] [Related]  

  • 58. An evaluation of the Du Pont aca IV: does it meet medical needs?
    Lott JA; Abbott LB; Koch DD
    Clin Chem; 1985 Feb; 31(2):281-6. PubMed ID: 3967365
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Near infrared reflectance analysis: features and applications in pharmaceutical and biomedical analysis.
    Corti P; Dreassi E; Leonardi S
    Farmaco; 1993 Jan; 48(1):3-20. PubMed ID: 8457277
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Rapid determination of plasma glucose by measurement of oxygen consumption.
    Skerry DW
    Clin Biochem; 1970 Dec; 3(4):319-26. PubMed ID: 5527101
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.