These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 6488748)

  • 1. Effects of dressing type and change interval on intravenous therapy complication rates.
    Gantz NM; Presswood GM; Goldberg R; Doern G
    Diagn Microbiol Infect Dis; 1984 Sep; 2(4):325-32. PubMed ID: 6488748
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of dressing regimens for prevention of infection with peripheral intravenous catheters. Gauze, a transparent polyurethane dressing, and an iodophor-transparent dressing.
    Maki DG; Ringer M
    JAMA; 1987 Nov; 258(17):2396-403. PubMed ID: 3118061
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bacterial colonization and phlebitis-associated risk with transparent polyurethane film for peripheral intravenous site dressings.
    Hoffmann KK; Western SA; Kaiser DL; Wenzel RP; Groschel DH
    Am J Infect Control; 1988 Jun; 16(3):101-6. PubMed ID: 3408013
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Daily change of an antiseptic dressing does not prevent infusion phlebitis: a controlled trial.
    Leibovici L
    Am J Infect Control; 1989 Feb; 17(1):23-5. PubMed ID: 2646988
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Complications of intravascular catheters in ICU: definitions, incidence and severity. A randomized controlled trial comparing usual transparent dressings versus new-generation dressings (the ADVANCED study).
    Günther SC; Schwebel C; Hamidfar-Roy R; Bonadona A; Lugosi M; Ara-Somohano C; Minet C; Potton L; Cartier JC; Vésin A; Chautemps M; Styfalova L; Ruckly S; Timsit JF
    Intensive Care Med; 2016 Nov; 42(11):1753-1765. PubMed ID: 27734108
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of central venous catheter dressings in bone marrow transplant recipients.
    Brandt B; DePalma J; Irwin M; Shogan J; Lucke JF
    Oncol Nurs Forum; 1996 Jun; 23(5):829-36. PubMed ID: 8792352
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Effectiveness of the transparent sterile dressing vs standard to fix the peripheral venous catheter (PVC) on the incidence of phlebitis. A randomized controlled trial].
    Forni C; D'Alessandro F; Gambino O; Amodeo A; Pignotti E; Zanotti E; Tremosini M; Trofa C; Sabattini T; Matino F; Genco R; Schiavone M; Bombino C; Mini S; Rocchegiani L; Notarnicola T; Capezzali D; Boschi R; Loro L
    Assist Inferm Ric; 2012; 31(2):63-9. PubMed ID: 22825293
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A prospective, randomized trial of gauze and two polyurethane dressings for site care of pulmonary artery catheters: implications for catheter management.
    Maki DG; Stolz SS; Wheeler S; Mermel LA
    Crit Care Med; 1994 Nov; 22(11):1729-37. PubMed ID: 7956275
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A comparison of transparent polyurethane and dry gauze dressings for peripheral i.v. catheter sites: rates of phlebitis, infiltration, and dislodgment by patients.
    Tripepi-Bova KA; Woods KD; Loach MC
    Am J Crit Care; 1997 Sep; 6(5):377-81. PubMed ID: 9283675
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Peripheral intravenous catheter dressing and securement practice is associated with site complications and suboptimal dressing integrity: A secondary analysis of 40,637 catheters.
    Corley A; Ullman AJ; Mihala G; Ray-Barruel G; Alexandrou E; Rickard CM
    Int J Nurs Stud; 2019 Dec; 100():103409. PubMed ID: 31629208
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Complications of intravenous therapy with steel needles and Teflon catheters. A comparative study.
    Tully JL; Friedland GH; Baldini LM; Goldmann DA
    Am J Med; 1981 Mar; 70(3):702-6. PubMed ID: 7211903
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A randomized study comparing IV 3000 (transparent polyurethane dressing) to a dry gauze dressing for peripheral intravenous catheter sites.
    Madeo M; Martin C; Nobbs A
    J Intraven Nurs; 1997; 20(5):253-6. PubMed ID: 9369626
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Securing All intraVenous devices Effectively in hospitalised patients--the SAVE trial: study protocol for a multicentre randomised controlled trial.
    Rickard CM; Marsh N; Webster J; Playford EG; McGrail MR; Larsen E; Keogh S; McMillan D; Whitty JA; Choudhury MA; Dunster KR; Reynolds H; Marshall A; Crilly J; Young J; Thom O; Gowardman J; Corley A; Fraser JF
    BMJ Open; 2015 Sep; 5(9):e008689. PubMed ID: 26399574
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dressings and securements for the prevention of peripheral intravenous catheter failure in adults (SAVE): a pragmatic, randomised controlled, superiority trial.
    Rickard CM; Marsh N; Webster J; Runnegar N; Larsen E; McGrail MR; Fullerton F; Bettington E; Whitty JA; Choudhury MA; Tuffaha H; Corley A; McMillan DJ; Fraser JF; Marshall AP; Playford EG
    Lancet; 2018 Aug; 392(10145):419-430. PubMed ID: 30057103
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Gauze and tape and transparent polyurethane dressings for central venous catheters.
    Webster J; Gillies D; O'Riordan E; Sherriff KL; Rickard CM
    Cochrane Database Syst Rev; 2011 Nov; (11):CD003827. PubMed ID: 22071809
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Daily dressing change effects on skin flora beneath subclavian catheter dressings during total parenteral nutrition.
    Jarrard MM; Olson CM; Freeman JB
    JPEN J Parenter Enteral Nutr; 1980; 4(4):391-2. PubMed ID: 6774123
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Contamination of intravenous infusion fluid: effects of changing administration sets.
    Buxton AE; Highsmith AK; Garner JS; West CM; Stamm WE; Dixon RE; McGowan JE
    Ann Intern Med; 1979 May; 90(5):764-8. PubMed ID: 373560
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Novel technologies can provide effective dressing and securement for peripheral arterial catheters: A pilot randomised controlled trial in the operating theatre and the intensive care unit.
    Reynolds H; Taraporewalla K; Tower M; Mihala G; Tuffaha HW; Fraser JF; Rickard CM
    Aust Crit Care; 2015 Aug; 28(3):140-8. PubMed ID: 25583412
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Chlorhexidine-impregnated sponges and less frequent dressing changes for prevention of catheter-related infections in critically ill adults: a randomized controlled trial.
    Timsit JF; Schwebel C; Bouadma L; Geffroy A; Garrouste-Orgeas M; Pease S; Herault MC; Haouache H; Calvino-Gunther S; Gestin B; Armand-Lefevre L; Leflon V; Chaplain C; Benali A; Francais A; Adrie C; Zahar JR; Thuong M; Arrault X; Croize J; Lucet JC;
    JAMA; 2009 Mar; 301(12):1231-41. PubMed ID: 19318651
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Split-thickness skin graft donor site management. A randomized prospective trial comparing a hydrophilic polyurethane absorbent foam dressing with a petrolatum gauze dressing.
    Weber RS; Hankins P; Limitone E; Callender D; Frankenthaler RM; Wolf P; Goepfert H
    Arch Otolaryngol Head Neck Surg; 1995 Oct; 121(10):1145-9. PubMed ID: 7546582
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.