These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 6494416)

  • 1. [The Coulter counter S-plus model: accuracy and normal values in platelet count].
    Biliotti G; Ridolfi B
    Quad Sclavo Diagn; 1984 Mar; 20(1):63-71. PubMed ID: 6494416
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Evaluation of platelet parameters obtained using the Coulter Counter S Plus in a normal population].
    Marugán I; Sabater V; Sanjuán L; García-Conde J
    Sangre (Barc); 1983; 28(4):512-22. PubMed ID: 6658641
    [No Abstract]   [Full Text] [Related]  

  • 3. Comparison of two platelet count estimation methodologies for peripheral blood smears.
    Malok M; Titchener EH; Bridgers C; Lee BY; Bamberg R
    Clin Lab Sci; 2007; 20(3):154-60. PubMed ID: 17691671
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The Coulter Counter Model S Plus--the shape of things to come.
    Rowan RM; Fraser C; Gray JH; McDonald GA
    Clin Lab Haematol; 1979; 1(1):29-40. PubMed ID: 535302
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hematologic values of New Zealand white rabbits determined by automated flow cytometry.
    Kabata J; Gratwohl A; Tichelli A; John L; Speck B
    Lab Anim Sci; 1991 Dec; 41(6):613-9. PubMed ID: 1667209
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Evaluation of the blood analyzer Beckman Coulter LH 750: analytic performance, decision rules].
    Amouroux I; Balay M; Marfaing-Koka A
    Ann Biol Clin (Paris); 2003; 61(5):576-84. PubMed ID: 14671756
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Platelet count and distribution of platelet volume in whole blood using a Coulter S Plus. Demonstration of errors not detected by the apparatus].
    Dumoulin-Lagrange M; Capelle C; Samama M
    Nouv Rev Fr Hematol (1978); 1984; 26(6):403-8. PubMed ID: 6527947
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The Coulter Counter leukocyte differential.
    Richardson-Jones A; Hellman R; Twedt D
    Blood Cells; 1985; 11(2):203-40. PubMed ID: 3834962
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Comparative and simultaneous evaluation of three automated counters in hematology: Coulter STKS, Sysmex NE 8000, Technicon H-2].
    Cart-Lamy P; Pernod G; Pirraud M; Drevait JM; Caillat D; Polack B; Kolodié L
    Ann Biol Clin (Paris); 1993; 51(6):627-35. PubMed ID: 8172402
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Platelet count evaluation using three automated haematology analysers compared with the immunoplatelet reference method, and estimation of possible inadequate platelet transfusion.
    Hong KH; Kim MJ; Lee KW; Park KU; Kim HS; Song J
    Int J Lab Hematol; 2009 Jun; 31(3):298-306. PubMed ID: 18294237
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Platelet counting by the coulter LH 750, sysmex XE 2100, and advia 120: a comparative analysis using the RBC/platelet ratio reference method.
    Sandhaus LM; Osei ES; Agrawal NN; Dillman CA; Meyerson HJ
    Am J Clin Pathol; 2002 Aug; 118(2):235-41. PubMed ID: 12162684
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The platelet count accuracy of platelet concentrates obtained by using automated analysis is influenced by instrument bias and activated platelet components.
    Hervig T; Haugen T; Liseth K; Kjeldsen-Kragh J; Scott CS; Johannessen B
    Vox Sang; 2004 Oct; 87(3):196-203. PubMed ID: 15569073
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Evaluation of the System 9000-AX autoanalyzer].
    Las Heras G; Millá F; Ribera JM; Oriol A; Feliu E
    Sangre (Barc); 1993 Apr; 38(2):97-102. PubMed ID: 8516735
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Automated platelet counters: a comparative evaluation of latest instrumentation.
    Mayer K; Chin B; Magnes J; Thaler HT; Lotspeich C; Baisley A
    Am J Clin Pathol; 1980 Aug; 74(2):135-50. PubMed ID: 7405891
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Measurement of spontaneous platelet aggregation in citrated whole blood by application of the hematologic automatic Coulter S plus VI].
    Kätzel R; Lösche W; Selle B
    Z Med Lab Diagn; 1991; 32(1):44-9. PubMed ID: 2068852
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of the Contraves Autolyzer 801.
    Lim YC; Cheong SK; Joyce JA; Ainoon O; Jeyasekeran V; Menaka N
    Malays J Pathol; 1990 Jun; 12(1):43-9. PubMed ID: 2090889
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Platelet counting errors with the Coulter counter Model "S' Plus.
    Guthrie DL; Campbell SR; Maidment NJ
    Med Lab Sci; 1981 Oct; 38(4):385-8. PubMed ID: 7329224
    [No Abstract]   [Full Text] [Related]  

  • 18. Performance evaluation of the Z2 coulter counter for WBC and RBC counting.
    Peng L; Wang W; Bai L
    Int J Lab Hematol; 2007 Oct; 29(5):361-8. PubMed ID: 17824917
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An assessment of the Coulter Counter Models S Plus II and III.
    England JM; Bain BJ; Chetty MC; Broom G; Dean A
    Clin Lab Haematol; 1983; 5(4):399-412. PubMed ID: 6667603
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Performance Evaluation of the Plateletworks® in the Measurement of Blood Cell Counts as compared to the Beckman Coulter Unicel DXH 800.
    McNair E; Qureshi AM; Bally C
    J Extra Corpor Technol; 2015 Jun; 47(2):113-8. PubMed ID: 26405360
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.