These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

66 related articles for article (PubMed ID: 6502003)

  • 1. Model prediction of plasma volume change induced by hemodialysis.
    Kimura G; Van Stone JC; Bauer JH
    J Lab Clin Med; 1984 Dec; 104(6):932-8. PubMed ID: 6502003
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The influence of sodium profiling on blood volume and intradialytic hypotension in patients on maintenance hemodialysis.
    Kaczmarczyk I; Kraśniak A; Drozdz M; Chowaniec E; Gajda M; Radziszewski A; Sułowicz W
    Przegl Lek; 2007; 64(7-8):476-82. PubMed ID: 18409348
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dialysis-induced change in erythrocyte volume: effect on change in blood volume calculated from packed cell volume.
    Fleming SJ; Wilkinson JS; Aldridge C; Greenwood RN; Muggleston SD; Baker LR; Cattell WR
    Clin Nephrol; 1988 Feb; 29(2):63-8. PubMed ID: 3359696
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intradialytic changes of serum magnesium and their relation to hypotensive episodes in hemodialysis patients on different dialysates.
    Elsharkawy MM; Youssef AM; Zayoon MY
    Hemodial Int; 2006 Oct; 10 Suppl 2():S16-23. PubMed ID: 17022745
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Fluid dynamics during hemodialysis in relationship to sodium gradient between dialysate and plasma.
    Sarkar SR; Wystrychowski G; Zhu F; Usvyat LA; Kotanko P; Levin NW
    ASAIO J; 2007; 53(3):339-42. PubMed ID: 17515726
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Effect of automated blood volume control on the incidence of intra-dialysis hypotension].
    Germin Petrović D
    Acta Med Croatica; 2003; 57(1):17-22. PubMed ID: 12876857
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Impact of sodium and ultrafiltration profiling on haemodialysis-related hypotension.
    Zhou YL; Liu HL; Duan XF; Yao Y; Sun Y; Liu Q
    Nephrol Dial Transplant; 2006 Nov; 21(11):3231-7. PubMed ID: 16954178
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The role of sequential ultrafiltration and varying dialysate sodium on vascular stability during hemodialysis.
    Po CL; Afolabi M; Raja RM
    ASAIO J; 1993; 39(3):M798-800. PubMed ID: 8268648
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A simulation study on transcellular fluid shifts induced by hemodialysis.
    Kimura G; Van Stone JC; Bauer JH; Keshaviah PR
    Kidney Int; 1983 Oct; 24(4):542-8. PubMed ID: 6645218
    [TBL] [Abstract][Full Text] [Related]  

  • 10. 1alpha(OH)D3 One-alpha-hydroxy-cholecalciferol--an active vitamin D analog. Clinical studies on prophylaxis and treatment of secondary hyperparathyroidism in uremic patients on chronic dialysis.
    Brandi L
    Dan Med Bull; 2008 Nov; 55(4):186-210. PubMed ID: 19232159
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Haemodialysis with on-line monitoring equipment: tools or toys?
    Locatelli F; Buoncristiani U; Canaud B; Köhler H; Petitclerc T; Zucchelli P
    Nephrol Dial Transplant; 2005 Jan; 20(1):22-33. PubMed ID: 15632348
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Assessment of salt intake in hemodialysis].
    Maduell F; Navarro V
    Nefrologia; 2001; 21(1):71-7. PubMed ID: 11344965
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effectiveness of sodium and conductivity kinetic models in predicting end-dialysis plasma water sodium concentration: preliminary results of a single-center experience.
    Pozzoni P; DI Filippo S; Pontoriero G; Locatelli F
    Hemodial Int; 2007 Apr; 11(2):169-77. PubMed ID: 17403167
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Use of dialysate conductivity to obtain neutral sodium balance in chronic hemodialysis patients].
    Di Filippo S; Manzoni C; Pozzoni P; Locatelli F
    G Ital Nefrol; 2005; 22(4):321-8. PubMed ID: 16267792
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Usefulness of the Biofeedback Diacontrol module in the automatic programming of plasmatic conductivity and ionic mass transfer].
    Hernández-Jaras J; García-Pérez H; Torregrosa E; Calvo C; Cerrillo V
    Nefrologia; 2003; 23(1):62-70. PubMed ID: 12708378
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Role of sodium in the control of compartmental distribution of water during hemodialysis. I. Measurement of water transfer].
    Brunois JP; Toupance O; Vistelle R; Choisy H; Chanard J
    Nephrologie; 1984; 5(1):27-31. PubMed ID: 6728100
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Simulation study of the intercompartmental fluid shifts during hemodialysis.
    Akcahuseyin E; Nette RW; Vincent HH; van Duyl WA; Krepel H; Weimar W; Zietse R
    ASAIO J; 2000; 46(1):81-94. PubMed ID: 10667723
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Evaluation of plasma volume variation during different hemodialysis maneuvers].
    Coll E; Vallès M; Torguet P; Bronsoms J; Maté G; Mauri JM
    Nefrologia; 2004; 24(5):463-9. PubMed ID: 15648904
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optimal composition of the dialysate, with emphasis on its influence on blood pressure.
    Locatelli F; Covic A; Chazot C; Leunissen K; Luño J; Yaqoob M
    Nephrol Dial Transplant; 2004 Apr; 19(4):785-96. PubMed ID: 15031331
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The hemodynamic effect of different ultrafiltration rates in patients with cardiac failure and patients without cardiac failure: comparison between isolated ultrafiltration and ultrafiltration with dialysis.
    van der Sande FM; Mulder AW; Hoorntje SJ; Peels KH; van Kuijk WH; Kooman JP; Leunissen KM
    Clin Nephrol; 1998 Nov; 50(5):301-8. PubMed ID: 9840318
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.