These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

80 related articles for article (PubMed ID: 6503672)

  • 21. Ion implantation and thermal nitridation of biocompatible titanium.
    Torrisi L
    Biomed Mater Eng; 1996; 6(5):379-88. PubMed ID: 8986358
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Enhanced surface hardness by boron implantation in Nitinol alloy.
    Lee DH; Park B; Saxena A; Serene TP
    J Endod; 1996 Oct; 22(10):543-6. PubMed ID: 9198443
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A comparison of stainless steel and nickel-titanium H-type instruments of identical design: torsional and bending tests.
    Kazemi RB; Stenman E; Spångberg LS
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2000 Oct; 90(4):500-6. PubMed ID: 11027388
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Structural effects of sodium hypochlorite solution on RaCe rotary nickel-titanium instruments: an atomic force microscopy study.
    Topuz O; Aydin C; Uzun O; Inan U; Alacam T; Tunca YM
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2008 May; 105(5):661-5. PubMed ID: 18329912
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Mechanical properties of the binary titanium-zirconium alloys and their potential for biomedical materials.
    Kobayashi E; Matsumoto S; Doi H; Yoneyama T; Hamanaka H
    J Biomed Mater Res; 1995 Aug; 29(8):943-50. PubMed ID: 7593037
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of surface reaction layer on grindability of cast titanium alloys.
    Ohkubo C; Hosoi T; Ford JP; Watanabe I
    Dent Mater; 2006 Mar; 22(3):268-74. PubMed ID: 16083955
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The effect of electropolishing on torque and force during simulated root canal preparation with ProTaper shaping files.
    Boessler C; Paque F; Peters OA
    J Endod; 2009 Jan; 35(1):102-6. PubMed ID: 19084135
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Surface modification by alkali and heat treatments in titanium alloys.
    Lee BH; Do Kim Y; Shin JH; Hwan Lee K
    J Biomed Mater Res; 2002 Sep; 61(3):466-73. PubMed ID: 12115472
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Differential scanning calorimetric studies of nickel-titanium rotary endodontic instruments after simulated clinical use.
    Brantley WA; Svec TA; Iijima M; Powers JM; Grentzer TH
    J Endod; 2002 Nov; 28(11):774-8. PubMed ID: 12470023
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Metallic ion release in artificial saliva of titanium oral implants coupled with different metal superstructures.
    Cortada M; Giner L; Costa S; Gil FJ; Rodríguez D; Planell JA
    Biomed Mater Eng; 1997; 7(3):213-20. PubMed ID: 9262834
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Evaluation of the surface characteristics of used and new ProTaper Instruments: an atomic force microscopy study.
    Inan U; Aydin C; Uzun O; Topuz O; Alacam T
    J Endod; 2007 Nov; 33(11):1334-7. PubMed ID: 17963958
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Reinforcement of the operating elements of medical instruments].
    Sabitov VKh; Levin MV; Matukhnov VM; Gerasev GP
    Med Tekh; 1979; (4):39-43. PubMed ID: 481166
    [TBL] [Abstract][Full Text] [Related]  

  • 33. NiTi shape memory alloys treated by plasma-polymerized tetrafluoroethylene. A physicochemical and electrochemical characterization.
    Yahia LH; Lombardi S; Piron D; Klemberg-Sapieha JE; Wertheimer MR
    Med Prog Technol; 1996-1997; 21(4):187-93. PubMed ID: 9110276
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Surface structure and properties of biomedical NiTi shape memory alloy after Fenton's oxidation.
    Chu CL; Hu T; Wu SL; Dong YS; Yin LH; Pu YP; Lin PH; Chung CY; Yeung KW; Chu PK
    Acta Biomater; 2007 Sep; 3(5):795-806. PubMed ID: 17466609
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Influence of phase transformation on the torsional and bending properties of nickel-titanium rotary endodontic instruments.
    Miyai K; Ebihara A; Hayashi Y; Doi H; Suda H; Yoneyama T
    Int Endod J; 2006 Feb; 39(2):119-26. PubMed ID: 16454792
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Titanium dental copings prepared by a powder metallurgy method: a preliminary report.
    Eriksson M; Andersson M; Carlström E
    Int J Prosthodont; 2004; 17(1):11-6. PubMed ID: 15008226
    [TBL] [Abstract][Full Text] [Related]  

  • 37. SEM observations and differential scanning calorimetric studies of new and sterilized nickel-titanium rotary endodontic instruments.
    Alexandrou GB; Chrissafis K; Vasiliadis LP; Pavlidou E; Polychroniadis EK
    J Endod; 2006 Jul; 32(7):675-9. PubMed ID: 16793479
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Cyclic fatigue of different nickel-titanium endodontic rotary instruments.
    Tripi TR; Bonaccorso A; Condorelli GG
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2006 Oct; 102(4):e106-14. PubMed ID: 16997084
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [RESEARCH ON SOLDERING TITANIUM ALLOYS FOR MEDICAL EQUIPMENT].
    BELAVIN NF; SHAKHMATOV VG
    Med Prom SSSR; 1964 May; 18():51-3. PubMed ID: 14224122
    [No Abstract]   [Full Text] [Related]  

  • 40. Bioactivity of titanium following sodium plasma immersion ion implantation and deposition.
    Maitz MF; Poon RW; Liu XY; Pham MT; Chu PK
    Biomaterials; 2005 Sep; 26(27):5465-73. PubMed ID: 15860203
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 4.