  • 1. [Method of electrochemical studies on the effect of corrosive media on the corrosion resistance of medical instruments].
    Bogomolova SN; Gordashnik KZ; Gerasimov IV; Marinich MA
    Med Tekh; 1984; (5):45-8. PubMed ID: 6503673
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Use of corrosion inhibitors during the sterilization and disinfection of medical instruments].
    Talalina AS; Kochanova LG; Anan'eva AI; Romanova AA
    Med Tekh; 1984; (4):30-3. PubMed ID: 6482716
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Electrochemical study of Type 304 and 316L stainless steels in simulated body fluids and cell cultures.
    Tang YC; Katsuma S; Fujimoto S; Hiromoto S
    Acta Biomater; 2006 Nov; 2(6):709-15. PubMed ID: 16935040
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparative corrosion study of "Ni-free" austenitic stainless steels in view of medical applications.
    Reclaru L; Ziegenhagen R; Eschler PY; Blatter A; Lemaître J
    Acta Biomater; 2006 Jul; 2(4):433-44. PubMed ID: 16765883
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Evaluation of corrosiveness of new disinfecting solutions in relation to medical instruments].
    Blazheevskiĭ NE; Levitin EIa; Roĭ ID; Sevidova EK
    Med Tekh; 1997; (5):38-40. PubMed ID: 9445981
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Microbial corrosion of stainless steel.
    Ibars JR; Moreno DA; Ranninger C
    Microbiologia; 1992 Nov; 8(2):63-75. PubMed ID: 1492953
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Stainless steels for medical instruments].
    Feofilov RN
    Med Tekh; 1981; (5):35-8. PubMed ID: 7300626
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Corrosion behavior of sensitized duplex stainless steel.
    Torres FJ; Panyayong W; Rogers W; Velasquez-Plata D; Oshida Y; Moore BK
    Biomed Mater Eng; 1998; 8(1):25-36. PubMed ID: 9713683
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Effect of fibrinogen on corrosion behavior of stainless steel in artificial blood solution].
    Guo L; Liang C; Guo H; Chen W
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2001 Dec; 18(4):565-7. PubMed ID: 11791309
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [New high-strength corrosion-resistant steel for medical instruments].
    Grachev SV; Mal'tseva LA; Shcherbakov VD
    Med Tekh; 1995; (2):24-7. PubMed ID: 7791563
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of alpha/gamma phase ratio on corrosion behavior of dual-phase stainless steels.
    Lim YJ; Reyes M; Thongthammachat S; Sukchit K; Panich M; Oshida Y
    Biomed Mater Eng; 1999; 9(5-6):277-83. PubMed ID: 10822483
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Measurement of low corrosion rate of coronary stents-made of 316L and 317L stainless steel].
    Liang C; Guo L; Chen W
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Aug; 23(4):829-31. PubMed ID: 17002118
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Enhancement of biocompatibility of 316LVM stainless steel by cyclic potentiodynamic passivation.
    Shahryari A; Omanovic S; Szpunar JA
    J Biomed Mater Res A; 2009 Jun; 89(4):1049-62. PubMed ID: 18478556
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Use of corrosion inhibitors during the presterilization preparation of medical instruments].
    Sverdlov AI; Sher LB; Kochanova LG
    Med Tekh; 1978; (6):34-7. PubMed ID: 723537
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Testing the corrosion resistance of stainless steels during the fermentation of probiotic drink.
    Pečar D; Slemnik M; Goršek A
    J Sci Food Agric; 2011 May; 91(7):1293-7. PubMed ID: 21337579
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Possible use of new corrosion-resistant steels in the manufacture of medical instruments].
    Birman SR; Starozhitskiĭ MI; Kuznetsov AM
    Med Tekh; 1978; (1):35-8. PubMed ID: 642760
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Anodized titanium and stainless steel in contact with CFRP: an electrochemical approach considering galvanic corrosion.
    Mueller Y; Tognini R; Mayer J; Virtanen S
    J Biomed Mater Res A; 2007 Sep; 82(4):936-46. PubMed ID: 17335021
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Study of a new medical stainless steel].
    Ren Y; Yang K; Zhang B; Yang H
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2006 Oct; 23(5):1101-3, 1122. PubMed ID: 17121363
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Preparation and characterization of sol-gel hydroxyapatite and its electrochemical evaluation for biomedical applications.
    Vijayalakshmi U; Prabakaran K; Rajeswari S
    J Biomed Mater Res A; 2008 Dec; 87(3):739-49. PubMed ID: 18200538
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Effects of skeletal muscle proteins on corrosion of stainless steels].
    Rojas C; Lago ME
    Acta Cient Venez; 2002; 53(2):156-63. PubMed ID: 12516369
    [TBL] [Abstract][Full Text] [Related]  