These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 6505015)

  • 1. Energy imparted to the patient in diagnostic radiology: calculation of conversion factors for determining the energy imparted from measurements of the air collision kerma integrated over beam area.
    Alm Carlsson G; Carlsson CA; Persliden J
    Phys Med Biol; 1984 Nov; 29(11):1329-41. PubMed ID: 6505015
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Conversion factors between energy imparted to the patient and air collision kerma integrated over beam area in pediatric radiology.
    Persliden J; Sandborg M
    Acta Radiol; 1993 Jan; 34(1):92-8. PubMed ID: 8427757
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Energy imparted to water slabs by photons in the energy range 5-300 keV. Calculations using a Monte Carlo photon transport model.
    Persliden J; Carlsson GA
    Phys Med Biol; 1984 Sep; 29(9):1075-88. PubMed ID: 6483973
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Use of the concept of energy imparted in diagnostic radiology.
    Carlsson GA; Dance DR; Persliden J; Sandborg M
    Appl Radiat Isot; 1999 Jan; 50(1):39-62. PubMed ID: 10028627
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Scatter rejection by air gaps in diagnostic radiology. Calculations using a Monte Carlo collision density method and consideration of molecular interference in coherent scattering.
    Persliden J; Carlsson GA
    Phys Med Biol; 1997 Jan; 42(1):155-75. PubMed ID: 9015816
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Computation of energy imparted in diagnostic radiology.
    Gkanatsios NA; Huda W
    Med Phys; 1997 Apr; 24(4):571-9. PubMed ID: 9127310
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An investigation of entrance surface dose calculations for diagnostic radiology using Monte Carlo simulations and radiotherapy dosimetry formalisms.
    Omrane LB; Verhaegen F; Chahed N; Mtimet S
    Phys Med Biol; 2003 Jun; 48(12):1809-24. PubMed ID: 12870585
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The measurement of energy imparted to patients during diagnostic x-ray examinations using the Diamentor exposure-area product meter.
    Shrimpton PC; Wall BF; Jones DG; Fisher ES
    Phys Med Biol; 1984 Oct; 29(10):1199-208. PubMed ID: 6494248
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Calculation of the small-angle distribution of scattered photons in diagnostic radiology using a Monte Carlo collision density estimator.
    Persliden J; Carlsson GA
    Med Phys; 1986; 13(1):19-24. PubMed ID: 3951405
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Review of Kerma-Area Product and total energy incident on patients in radiography, mammography and CT.
    Yao H; Huda W; Mah E; He W
    Radiat Prot Dosimetry; 2015 Feb; 163(2):251-60. PubMed ID: 24821931
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Secondary bremsstrahlung and the energy-conservation aspects of kerma in photon-irradiated media.
    Kumar S; Nahum AE
    Phys Med Biol; 2016 Feb; 61(3):1389-402. PubMed ID: 26797487
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Transmission ionization chambers for measurements of air collision kerma integrated over beam area. Factors limiting the accuracy of calibration.
    Larsson JP; Persliden J; Sandborg M; Carlsson GA
    Phys Med Biol; 1996 Nov; 41(11):2381-98. PubMed ID: 8938033
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Real-time estimation of surface dose based on incident air kerma in diagnostic radiology.
    Tanabe R; Araki F
    Phys Med; 2021 Sep; 89():176-181. PubMed ID: 34388557
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of mean conversion coefficients from air-kerma to H
    Lopez Gonzales AH; Santos JC; Mariano L; Tomal A; Costa PR
    J Radiol Prot; 2016 Dec; 36(4):842-857. PubMed ID: 27739403
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Technical Note: Patient-weight dependence of the effective dose conversion coefficients for diagnostic x-ray imaging procedures.
    Golikov V; Druzhinina P
    Med Phys; 2020 Oct; 47(10):5366-5372. PubMed ID: 32810872
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Measured and Monte Carlo simulated surface dose reduction for superficial X-rays incident on tissue with underlying air or bone.
    Baines J; Zawlodzka S; Markwell T; Chan M
    Med Phys; 2018 Feb; 45(2):926-933. PubMed ID: 29235131
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Air kerma calculation in Monte Carlo simulations for deriving normalized glandular dose coefficients in mammography.
    Sarno A; Mettivier G; Russo P
    Phys Med Biol; 2017 Jun; 62(14):N337-N349. PubMed ID: 28452342
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accounting for the variation in collision kerma-to-terma ratio in polyenergetic photon beam convolution.
    Hoban PW
    Med Phys; 1995 Dec; 22(12):2035-44. PubMed ID: 8746709
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Monte Carlo simulations in CT for the study of the surface air kerma and energy imparted to phantoms of varying size and position.
    Avilés Lucas P; Dance DR; Castellano IA; Vañó E
    Phys Med Biol; 2004 Apr; 49(8):1439-54. PubMed ID: 15152684
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Corrections to air kerma and exposure measured with free air ionisation chambers for charge of photoelectrons, Compton electrons and Auger electrons.
    Takata N; Begum A
    Radiat Prot Dosimetry; 2008; 130(4):410-8. PubMed ID: 18397932
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.