2. Characterization of Compton-scatter imaging with an analytical simulation method. Jones KC; Redler G; Templeton A; Bernard D; Turian JV; Chu JCH Phys Med Biol; 2018 Jan; 63(2):025016. PubMed ID: 29243663 [TBL] [Abstract][Full Text] [Related]
3. Effects of scattered X-rays on CT images. Kanamori H; Nakamori N; Inoue K; Takenaka E Phys Med Biol; 1985 Mar; 30(3):239-49. PubMed ID: 3983234 [TBL] [Abstract][Full Text] [Related]
4. Simulated scatter performance of an inverse-geometry dedicated breast CT system. Bhagtani R; Schmidt TG Med Phys; 2009 Mar; 36(3):788-96. PubMed ID: 19378739 [TBL] [Abstract][Full Text] [Related]
5. Strategies for scatter correction in dual source CT. Petersilka M; Stierstorfer K; Bruder H; Flohr T Med Phys; 2010 Nov; 37(11):5971-92. PubMed ID: 21158310 [TBL] [Abstract][Full Text] [Related]
6. Effect of scattered radiation on image noise in cone beam CT. Endo M; Tsunoo T; Nakamori N; Yoshida K Med Phys; 2001 Apr; 28(4):469-74. PubMed ID: 11339743 [TBL] [Abstract][Full Text] [Related]
7. Characterization of X-ray scattering for various phantoms and clinical breast geometries using breast CT on a dedicated hybrid system. Shah JP; Mann SD; Tornai MP J Xray Sci Technol; 2017; 25(3):373-389. PubMed ID: 28157120 [TBL] [Abstract][Full Text] [Related]
8. A two-step algorithm for predicting portal dose images in arbitrary detectors. McCurdy BM; Pistorius S Med Phys; 2000 Sep; 27(9):2109-16. PubMed ID: 11011740 [TBL] [Abstract][Full Text] [Related]
9. An analytical approach to estimating the first order x-ray scatter in heterogeneous medium. Yao W; Leszczynski KW Med Phys; 2009 Jul; 36(7):3145-56. PubMed ID: 19673213 [TBL] [Abstract][Full Text] [Related]
10. X-ray scatter correction for multi-source interior computed tomography. Gong H; Yan H; Jia X; Li B; Wang G; Cao G Med Phys; 2017 Jan; 44(1):71-83. PubMed ID: 28102959 [TBL] [Abstract][Full Text] [Related]
11. A fast and pragmatic approach for scatter correction in flat-detector CT using elliptic modeling and iterative optimization. Meyer M; Kalender WA; Kyriakou Y Phys Med Biol; 2010 Jan; 55(1):99-120. PubMed ID: 20009184 [TBL] [Abstract][Full Text] [Related]
12. A Monte Carlo study of the energy spectra and transmission characteristics of scattered radiation from x-ray computed tomography. Platten DJ J Radiol Prot; 2014 Jun; 34(2):445-56. PubMed ID: 24894101 [TBL] [Abstract][Full Text] [Related]
13. Compton scatter imaging of transverse sections: corrections for multiple scatter and attenuation. Battista JJ; Santon LW; Bronskill MJ Phys Med Biol; 1977 Mar; 22(2):229-44. PubMed ID: 854523 [TBL] [Abstract][Full Text] [Related]
14. Monte Carlo analysis of beam blocking grid design parameters: Scatter estimation and the importance of electron backscatter. Bootsma GJ; Ren L; Zhang H; Jin JY; Jaffray DA Med Phys; 2018 Mar; 45(3):1059-1070. PubMed ID: 29360154 [TBL] [Abstract][Full Text] [Related]
15. Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter - Part I: Core algorithms and validation. Maslowski A; Wang A; Sun M; Wareing T; Davis I; Star-Lack J Med Phys; 2018 May; 45(5):1899-1913. PubMed ID: 29509970 [TBL] [Abstract][Full Text] [Related]
16. Poster - Thur Eve - 14: The effect of fluence and detector size on image quality in multi-projection compton scatter tomography. Chighvinadze T; Pistorius S Med Phys; 2012 Jul; 39(7Part2):4626-4627. PubMed ID: 28516521 [TBL] [Abstract][Full Text] [Related]
17. The effect of detector size and energy resolution on image quality in multi-projection Compton scatter tomography. Chighvinadze T; Pistorius S J Xray Sci Technol; 2014; 22(1):113-28. PubMed ID: 24463390 [TBL] [Abstract][Full Text] [Related]
18. Empirical binary tomography calibration (EBTC) for the precorrection of beam hardening and scatter for flat panel CT. Grimmer R; Kachelriess M Med Phys; 2011 Apr; 38(4):2233-40. PubMed ID: 21626957 [TBL] [Abstract][Full Text] [Related]
19. Implementation and application of a Monte Carlo model for an in vivo micro computed tomography system. Manser P; Peter S; Volken W; Zulliger MA; Laib A; Koller B; Fix MK Phys Med; 2017 Dec; 44():34-41. PubMed ID: 29254589 [TBL] [Abstract][Full Text] [Related]
20. A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms. DeMarco JJ; Cagnon CH; Cody DD; Stevens DM; McCollough CH; O'Daniel J; McNitt-Gray MF Phys Med Biol; 2005 Sep; 50(17):3989-4004. PubMed ID: 16177525 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]