These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

113 related articles for article (PubMed ID: 650895)

  • 1. False inhibition of a demand pacemaker by inactive myocardial electrodes.
    Yokoyama M; Hori M; Hayashi H; Saito Y
    Jpn Heart J; 1978 Jan; 19(1):159-66. PubMed ID: 650895
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Suppression of demand mechanism by inactive myocardial electrodes.
    Yokoyama M; Hori M; Grechko M
    Pacing Clin Electrophysiol; 1978 Jan; 1(1):126-31. PubMed ID: 83608
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Incomplete lead fracture as a cause of bradyarrhythmia in patients with artificial pacemakers (author's transl)].
    Beyer J; Schaudig A; Stemple G; Zimmermann M
    Herz; 1978 Dec; 63(36):362-6. PubMed ID: 554857
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Extraction of infected pacemaker electrode using catheter and snare].
    Mizuno A; Kurosawa H; Wakabayashi K; Suzuki K; Mashiko K; Nakano M; Saitoh F
    Kyobu Geka; 1993 Oct; 46(11):937-40. PubMed ID: 8230906
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Suppression of an external demand pacemaker by diaphragmatic myopotentials: a sign of electrode perforation?
    El Gamal M; Van Gelder B
    Pacing Clin Electrophysiol; 1979 Mar; 2(2):191-5. PubMed ID: 95280
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Suppression of a demand pacemaker in the presence of redundant transvenous right ventricular leads.
    Tyers GF; Larrieu AJ; Nishimura A; Williams EH; Kurusz M; Brownlee RR
    Pacing Clin Electrophysiol; 1980 Jan; 3(1):84-7. PubMed ID: 6160498
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Demand pacemaker arrhythmias caused by intermittent incomplete electrode fracture. Diagnosis with testing magnet.
    Coumel P; Mugica J; Barold SS
    Am J Cardiol; 1975 Jul; 36(1):105-9. PubMed ID: 50002
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Septicemia secondary to impacted infected pacemaker wire. Successful treatment by removal with cardiopulmonary bypass.
    Chavez CM; Conn JH
    J Thorac Cardiovasc Surg; 1977 May; 73(5):796-800. PubMed ID: 321883
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Subepicardial infarction, myocardial impression, and ventricular penetration by sutureless electrode and leads.
    Steinke WE; Thomas FT; ul Hassan Z; Mendoza RA; Gear AS
    Chest; 1976 Jul; 70(1):80-1. PubMed ID: 1277940
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An unusual cause of asystole during a routine pacemaker generator change.
    Can I; Tholakanahalli V; Li JM
    Pacing Clin Electrophysiol; 2009 Jul; 32(7):949-51. PubMed ID: 19572876
    [TBL] [Abstract][Full Text] [Related]  

  • 11. False inhibition of an atrial demand pacemaker caused by an insulation defect in a polyurethane lead.
    van Gelder LM; El Gamal MI
    Pacing Clin Electrophysiol; 1983 Sep; 6(5 Pt 1):834-9. PubMed ID: 6195601
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Catheter-based rescue of a split pacemaker lead in the pulmonary artery].
    Drögemüller A; Schultz H; Senges J; Seidl K
    Z Kardiol; 2003 Oct; 92(10):884-8. PubMed ID: 14579054
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Suppression of demand pacemakers due to spurious signals generated by inactive endocardial electrodes.
    Oreto G; Bramanti O; Arrigo F; Carerj S; Consolo F
    Eur Heart J; 1983 Oct; 4(10):724-7. PubMed ID: 6653582
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pacemaker-generated stress fracture of the second rib: a case report.
    Ksela J; Racman M; Zbacnik R; Djordjevic A; Jan M
    J Cardiothorac Surg; 2020 Sep; 15(1):258. PubMed ID: 32938486
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An unusual distal abdominal migration of a pacemaker pulse generator with a complete epicardial lead fracture.
    Koulouris S; Pastromas S; Manolis AS
    Europace; 2008 Dec; 10(12):1461. PubMed ID: 18922816
    [No Abstract]   [Full Text] [Related]  

  • 16. [Clinical experiences and experimental studies of false sensing with demand pacemakers (author's transl)].
    Taniguchi K; Fujiwara H; Iizumi T; Niwa A; Shintomi Y
    Jpn Circ J; 1977 Apr; 41(4):413-4, 429-34. PubMed ID: 875229
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Electromechanical suppression of a demand pacemaker associated with electrode perforation.
    Rubenfire M; Timmis H; Freed P; Evangelista JL; Ginsberg H; Wajszczuk WJ
    J Electrocardiol; 1973; 6(4):367-71. PubMed ID: 4765332
    [No Abstract]   [Full Text] [Related]  

  • 18. Galvanic element produced by defective electrode insulation--a possible cause of abnormal pulse generator inhibition.
    Levander-Lindgren M; Sylvén JC; Thorén A
    Scand J Thorac Cardiovasc Surg; 1983; 17(1):85-8. PubMed ID: 6867647
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Spontaneous twisting of a pacemaker lead in an unusual site.
    Cay S; Ozturk S; Korkmaz S
    Pacing Clin Electrophysiol; 2005 Jul; 28(7):740-1. PubMed ID: 16008816
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Electrode ingrowths revealed during cadaveric dissection of a 5y old implanted pacemaker - the case report.
    Kuniewicz M; Walocha JA; Budnicka K; Mazur M; Walocha E; Jurczyk M
    Folia Med Cracov; 2019; 59(2):61-66. PubMed ID: 31659349
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.