  • 1. A serious hazard associated with the Fluotec mark 4 vaporizer.
    Carter JA; McAtteer P
    Anaesthesia; 1984 Dec; 39(12):1257-8. PubMed ID: 6517262
    [No Abstract]   [Full Text] [Related]  

  • 2. Failure of a Fluotec Mk II.
    Leiman BC; Kaplan S
    Anaesthesia; 1982 Sep; 37(9):937-9. PubMed ID: 7125167
    [No Abstract]   [Full Text] [Related]  

  • 3. [Vaporizer malfunction--a cause of high concentration halothane vapor delivery].
    Yamada T; Masuda J; Takeda J; Sekiguchi H; Fukushima K
    Masui; 1994 Mar; 43(3):421-5. PubMed ID: 8182893
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A hazard of the Penlon off-line vaporizer mounting system.
    Marsh RH; Thomas NF
    Anaesthesia; 1986 Apr; 41(4):437-8. PubMed ID: 3706700
    [No Abstract]   [Full Text] [Related]  

  • 5. Pumping effect of the Philips AVI ventilator on Fluotec vaporizers.
    Mackenzie N; Grant IS
    Br J Anaesth; 1983 Sep; 55(9):921-2. PubMed ID: 6577905
    [No Abstract]   [Full Text] [Related]  

  • 6. [Efficiency of Ethrane vaporization by fluotec vaporizer. 2. Gas chromatographic measurement of Ethrane concentration].
    Kudo M; Matsuki A; Kakuta Y; Nishikawa T; Oyama T
    Masui; 1972 Jun; 21(6):561-3. PubMed ID: 4672637
    [No Abstract]   [Full Text] [Related]  

  • 7. Vaporizer failure.
    Milligan K; Rodgers RC
    Anaesthesia; 1983 Oct; 38(10):997. PubMed ID: 6638447
    [No Abstract]   [Full Text] [Related]  

  • 8. Another hazard with the Penlon off-line vaporizer mounting system.
    Woollam CH
    Anaesthesia; 1987 Jul; 42(7):781-2. PubMed ID: 3631484
    [No Abstract]   [Full Text] [Related]  

  • 9. Free-standing vaporizers. Another hazard.
    Kelly DA
    Anaesthesia; 1985 Jul; 40(7):661-3. PubMed ID: 4025770
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Broken control on a Selectatec vaporizer.
    Davies JR
    Anaesthesia; 1987 Feb; 42(2):215. PubMed ID: 3826602
    [No Abstract]   [Full Text] [Related]  

  • 11. High halothane concentrations from reversed flow in a vaporizer.
    Railton R; Inglis MD
    Anaesthesia; 1986 Jun; 41(6):672-3. PubMed ID: 3728950
    [No Abstract]   [Full Text] [Related]  

  • 12. Intraoperative failure of a Fluotec Mark II vapourizer.
    Maltby JR
    Can Anaesth Soc J; 1985 Mar; 32(2):200. PubMed ID: 3986658
    [No Abstract]   [Full Text] [Related]  

  • 13. Accumulation of thymol in halothane vaporizers.
    Rosenberg PH; Alila A
    Anaesthesia; 1984 Jun; 39(6):581-3. PubMed ID: 6742392
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Vaporizer overfilling.
    Hardy JF
    Can J Anaesth; 1993 Jan; 40(1):1-3. PubMed ID: 8425235
    [No Abstract]   [Full Text] [Related]  

  • 15. Key issues in vaporizer filling.
    Uncles DR; Conway NE
    Can J Anaesth; 1994 Sep; 41(9):878-9. PubMed ID: 7955015
    [No Abstract]   [Full Text] [Related]  

  • 16. Evaluation of a new halothane vaporizer: the Cyprane Fluotec Mark 3.
    Paterson GM; Hulands GH; Nunn JF
    Br J Anaesth; 1969 Feb; 41(2):109-19. PubMed ID: 5774514
    [No Abstract]   [Full Text] [Related]  

  • 17. [Concentration of halothane delivered by Fluotec Mark II and in the vapor of the Dräger vaporizer at the "lock-off" position].
    Yanagawa F; Fujita T
    Masui; 1975 Jul; 24(7):695-8. PubMed ID: 1172539
    [No Abstract]   [Full Text] [Related]  

  • 18. Equipment malfunction: possible hazard.
    Duncan JA
    Anaesthesia; 1986 Dec; 41(12):1271. PubMed ID: 3812961
    [No Abstract]   [Full Text] [Related]  

  • 19. Effect of various carrier gases on the halothane output of the Fluotec Mark 3 vaporizer.
    Haskins SC; Knapp RG
    Am J Vet Res; 1980 Jan; 41(1):153-4. PubMed ID: 7189100
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Problems with anesthetic gas machines and their solutions.
    Rendell-Baker L
    Int Anesthesiol Clin; 1982; 20(3):1-82. PubMed ID: 6215357
    [No Abstract]   [Full Text] [Related]  