These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 6517262)

  • 41. Water vaporizer heated by the reaction of neutralization by carbon dioxide.
    Chalon J; Ramanathan S
    Anesthesiology; 1974 Oct; 41(4):400-4. PubMed ID: 4416888
    [No Abstract]   [Full Text] [Related]  

  • 42. Vaporizer and Selectatec leaks.
    Dwyer M; Holland R; Shepherd L; Smith K
    Anaesth Intensive Care; 1994 Dec; 22(6):739. PubMed ID: 7892989
    [No Abstract]   [Full Text] [Related]  

  • 43. Self testing machines--enhanced reliability or the source of a serious fault.
    Bathini K; O' Donohoe B; Laxton AG
    Anaesthesia; 2009 Jun; 64(6):696-7; discussion 697. PubMed ID: 19453338
    [No Abstract]   [Full Text] [Related]  

  • 44. Safety warning with Datex-Ohmeda S/5 anaesthetic delivery unit design.
    Weinberg L; Sawhney S; Skewes D
    Anaesth Intensive Care; 2004 Oct; 32(5):719-20. PubMed ID: 15535503
    [No Abstract]   [Full Text] [Related]  

  • 45. A slide rule developed for the performance approximation of the copper kettle vaporizer. (2) Addition of scales for new anesthetic agents.
    Saito T; Kokubo S; Matsuda F; Fukuda M; Akaeda Y
    Tokushima J Exp Med; 1976 Aug; 23():29-32. PubMed ID: 1014006
    [No Abstract]   [Full Text] [Related]  

  • 46. Vaporizer overfilling.
    Craig DB
    Can J Anaesth; 1993 Oct; 40(10):1005-6. PubMed ID: 8222026
    [No Abstract]   [Full Text] [Related]  

  • 47. Are trichloroethylene vaporisers accurate?
    Rees DG; Walker JA; Mathur AK
    Anaesthesia; 1981 Nov; 36(11):1060-1. PubMed ID: 7316125
    [No Abstract]   [Full Text] [Related]  

  • 48. Halothane and trichloroethylene. Two agents in a single vaporizer.
    Hollis N
    Anaesthesia; 1986 Mar; 41(3):309-15. PubMed ID: 3963336
    [TBL] [Abstract][Full Text] [Related]  

  • 49. An unusual vaporiser leak.
    Forrest T; Childs D
    Anaesthesia; 1982 Dec; 37(12):1220-1. PubMed ID: 7181077
    [No Abstract]   [Full Text] [Related]  

  • 50. Failed inhalational induction--a faulty vaporizer.
    Green M; Bugg N; Holt P
    Anaesthesia; 1995 Jan; 50(1):85-6. PubMed ID: 7702157
    [No Abstract]   [Full Text] [Related]  

  • 51. Selectatec system: misplaced blood.
    Goddard JM; Abbott TR
    Anaesthesia; 1986 Apr; 41(4):439. PubMed ID: 3706701
    [No Abstract]   [Full Text] [Related]  

  • 52. Nitrous oxide increases enflurane concentrations delivered by Ethrane vaporizers.
    Nawaf K; Stoelting RK
    Anesth Analg; 1979; 58(1):30-2. PubMed ID: 571219
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Con: there is nothing wrong with old anesthesia machines and equipment.
    Schreiber PJ
    J Clin Monit; 1996 Jan; 12(1):39-41. PubMed ID: 8732815
    [No Abstract]   [Full Text] [Related]  

  • 54. Gas leak due to faulty actuating spindles in a Tec 7 vaporizer.
    Amagasa S; Takahashi E; Murata N
    J Anesth; 2014 Dec; 28(6):954. PubMed ID: 24700314
    [No Abstract]   [Full Text] [Related]  

  • 55. Calibration of a methoxyflurane vaporizer for trichloroethylene.
    Rosenblatt RM; Randall F; Davis HS
    Br J Anaesth; 1979 Mar; 51(3):264. PubMed ID: 435353
    [No Abstract]   [Full Text] [Related]  

  • 56. Gas loss from Ohio Modulus Vaporizer Selector-Interlock Valve.
    Pyles ST; Kaplan RF; Munson ES
    Anesth Analg; 1983 Nov; 62(11):1052. PubMed ID: 6625215
    [No Abstract]   [Full Text] [Related]  

  • 57. [Leakage from the connecting portion between the anesthesia machine and vaporizer].
    Murata Y; Takahashi H; Tokuwaka J; Tanaka M
    Masui; 2013 Dec; 62(12):1472-5. PubMed ID: 24498787
    [TBL] [Abstract][Full Text] [Related]  

  • 58. [Vaporizing efficiency of the Ethranetec vaporizer].
    Kudo M; Oyama T; Aoki N
    Masui; 1972 Jun; 21(6):584-6. PubMed ID: 4672641
    [No Abstract]   [Full Text] [Related]  

  • 59. A hidden safety feature in the event of oxygen failure.
    Hearn CM; Chandradeva K
    Anaesthesia; 2003 Dec; 58(12):1240; discussion 1241. PubMed ID: 14705699
    [No Abstract]   [Full Text] [Related]  

  • 60. [3-Dimentional numerical simulation on internal flow and mixing process of an anesthesia vaporizer].
    Zou R; Chen B; Hu X; Yang S
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2011 Aug; 28(4):810-3. PubMed ID: 21936386
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.