These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
249 related articles for article (PubMed ID: 6520501)
1. [Experimental studies on polyacetal composites for joint prosthesis]. Maeda M Nihon Seikeigeka Gakkai Zasshi; 1984 Sep; 58(9):919-36. PubMed ID: 6520501 [TBL] [Abstract][Full Text] [Related]
2. [Experimental studies on "less rigid" polyacetal plates for fracture fixation (author's transl)]. Kusunose K Nihon Seikeigeka Gakkai Zasshi; 1982 May; 56(5):399-414. PubMed ID: 7108319 [TBL] [Abstract][Full Text] [Related]
3. Tribological behavior of artificial hip joint under the effects of magnetic field in dry and lubricated sliding. Zaki M; Aljinaidi A; Hamed M Biomed Mater Eng; 2003; 13(3):205-21. PubMed ID: 12883170 [TBL] [Abstract][Full Text] [Related]
4. Evaluation of wear in an all-polymer total knee replacement. Part 1: laboratory testing of polyethylene on polyacetal bearing surfaces. McKellop HA; Röstlund T; Bradley G Clin Mater; 1993; 14(2):117-26. PubMed ID: 10146440 [TBL] [Abstract][Full Text] [Related]
5. Friction and wear properties of polymer, metal, and ceramic prosthetic joint materials evaluated on a multichannel screening device. McKellop H; Clarke I; Markolf K; Amstutz H J Biomed Mater Res; 1981 Sep; 15(5):619-53. PubMed ID: 12659132 [TBL] [Abstract][Full Text] [Related]
6. Comparative study of the wear of UHMWPE with zirconia ceramic and stainless steel femoral heads in artificial hip joints. Derbyshire B; Fisher J; Dowson D; Hardaker C; Brummitt K Med Eng Phys; 1994 May; 16(3):229-36. PubMed ID: 8061909 [TBL] [Abstract][Full Text] [Related]
7. Tissue reactions to wear products from polyacetal (Delrin) and UHMW polyethylene in total hip replacement. Mathiesen EB; Lindgren JU; Reinholt FP; Sudmann E J Biomed Mater Res; 1987 Apr; 21(4):459-66. PubMed ID: 3294838 [TBL] [Abstract][Full Text] [Related]
8. Wear-testing of a temporomandibular joint prosthesis: UHMWPE and PTFE against a metal ball, in water and in serum. Van Loon JP; Verkerke GJ; de Bont LG; Liem RS Biomaterials; 1999 Aug; 20(16):1471-8. PubMed ID: 10458560 [TBL] [Abstract][Full Text] [Related]
9. A tribological study of UHMWPE acetabular cups and polyurethane compliant layer acetabular cups. Smith SL; Ash HE; Unsworth A J Biomed Mater Res; 2000; 53(6):710-6. PubMed ID: 11074431 [TBL] [Abstract][Full Text] [Related]
10. [Experimental study on an artificial hip joint made of Al2O3 ceramics (author's transl)]. Karasawa S Nihon Seikeigeka Gakkai Zasshi; 1979 Nov; 53(11):1579-94. PubMed ID: 393784 [TBL] [Abstract][Full Text] [Related]
11. Wear of polymeric bearing materials: the effects of in vivo implantation. Amstutz HC; Lodwig M J Biomed Mater Res; 1976 Jan; 10(1):25-31. PubMed ID: 1249088 [TBL] [Abstract][Full Text] [Related]
12. Frictional heating of bearing materials tested in a hip joint wear simulator. Lu Z; McKellop H Proc Inst Mech Eng H; 1997; 211(1):101-8. PubMed ID: 9141895 [TBL] [Abstract][Full Text] [Related]
13. Polyurethane unicondylar knee prostheses: simulator wear tests and lubrication studies. Scholes SC; Unsworth A; Jones E Phys Med Biol; 2007 Jan; 52(1):197-212. PubMed ID: 17183136 [TBL] [Abstract][Full Text] [Related]
14. The wear of two orthopaedic biopolymers against each other. Joyce TJ J Appl Biomater Biomech; 2005; 3(3):141-6. PubMed ID: 20799219 [TBL] [Abstract][Full Text] [Related]
15. Analysis and characterization of alumina particles reinforced ultra high molecular weight polyethylene composite for acetabular cup. Saha D; Bose PK; Banthia AK; Dhabal S Int J Artif Organs; 2007 Feb; 30(2):144-52. PubMed ID: 17377909 [TBL] [Abstract][Full Text] [Related]
16. Wear of the acetabular socket. Comparison of polyacetal and polyethylene. Mathiesen EB; Lindgren U; Reinholt FP; Sudmann E Acta Orthop Scand; 1986 Jun; 57(3):193-6. PubMed ID: 3739654 [TBL] [Abstract][Full Text] [Related]
17. Wear properties of alumina/zirconia composite ceramics for joint prostheses measured with an end-face apparatus. Morita Y; Nakata K; Kim YH; Sekino T; Niihara K; Ikeuchi K Biomed Mater Eng; 2004; 14(3):263-70. PubMed ID: 15299238 [TBL] [Abstract][Full Text] [Related]
18. Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulators. Tipper JL; Galvin AL; Williams S; McEwen HM; Stone MH; Ingham E; Fisher J J Biomed Mater Res A; 2006 Sep; 78(3):473-80. PubMed ID: 16721797 [TBL] [Abstract][Full Text] [Related]
19. [Improve wear resistance of UHMWPE by O+ ion implanted]. Xiong D Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2003 Dec; 20(4):583-5, 596. PubMed ID: 14716850 [TBL] [Abstract][Full Text] [Related]
20. Cementless total joint arthroplasty prostheses with titanium-alloy articular surfaces. A human retrieval analysis. Nasser S; Campbell PA; Kilgus D; Kossovsky N; Amstutz HC Clin Orthop Relat Res; 1990 Dec; (261):171-85. PubMed ID: 2245543 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]