These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 6525392)

  • 1. Silane crosslinked polyethylene for prosthetic applications. II. Creep and wear behaviour and a preliminary moulding test.
    Atkinson JR; Cicek RZ
    Biomaterials; 1984 Nov; 5(6):326-35. PubMed ID: 6525392
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Silane cross-linked polyethylene for prosthetic applications. Part I. Certain physical and mechanical properties related to the nature of the material.
    Atkinson JR; Cicek RZ
    Biomaterials; 1983 Oct; 4(4):267-75. PubMed ID: 6640052
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Unified wear model for highly crosslinked ultra-high molecular weight polyethylenes (UHMWPE).
    Muratoglu OK; Bragdon CR; O'Connor DO; Jasty M; Harris WH; Gul R; McGarry F
    Biomaterials; 1999 Aug; 20(16):1463-70. PubMed ID: 10458559
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Effect of the manufacturing process on creep and wear properties of UHMWPE (ultra-high molecular weight polyethylene)].
    Huber J; Walter A; Plitz W; Refior HJ
    Biomed Tech (Berl); 1995 Apr; 40(4):88-92. PubMed ID: 7772710
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements.
    McKellop H; Shen FW; Lu B; Campbell P; Salovey R
    J Orthop Res; 1999 Mar; 17(2):157-67. PubMed ID: 10221831
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Factors contributing to the wear of polyethylene in clinical practice.
    Learmonth ID; Cunningham JL
    Proc Inst Mech Eng H; 1997; 211(1):49-57. PubMed ID: 9141890
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Wear and creep of highly crosslinked polyethylene against cobalt chrome and ceramic femoral heads.
    Galvin AL; Jennings LM; Tipper JL; Ingham E; Fisher J
    Proc Inst Mech Eng H; 2010 Oct; 224(10):1175-83. PubMed ID: 21138235
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparison of the wear and physical properties of silane cross-linked polyethylene and ultra-high molecular weight polyethylene.
    Sakoda H; Voice AM; McEwen HM; Isaac GH; Hardaker C; Wroblewski BM; Fisher J
    J Arthroplasty; 2001 Dec; 16(8):1018-23. PubMed ID: 11740757
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The seven-year wear of highly cross-linked polyethylene in total hip arthroplasty: a double-blind, randomized controlled trial using radiostereometric analysis.
    Thomas GE; Simpson DJ; Mehmood S; Taylor A; McLardy-Smith P; Gill HS; Murray DW; Glyn-Jones S
    J Bone Joint Surg Am; 2011 Apr; 93(8):716-22. PubMed ID: 21508278
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements.
    Goldsmith AA; Dowson D; Isaac GH; Lancaster JG
    Proc Inst Mech Eng H; 2000; 214(1):39-47. PubMed ID: 10718049
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparison of RCH 1000 and Hi-Fax 1900 ultra-high molecular weight polyethylenes.
    Weightman B; Light D
    Biomaterials; 1985 May; 6(3):177-83. PubMed ID: 4005361
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of the properties of annealed crosslinked (Crossfire) and conventional polyethylene as hip bearing materials.
    Kurtz SM; Manley M; Wang A; Taylor S; Dumbleton J
    Bull Hosp Jt Dis; 2002-2003; 61(1-2):17-26. PubMed ID: 12828375
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene.
    Endo MM; Barbour PS; Barton DC; Fisher J; Tipper JL; Ingham E; Stone MH
    Biomed Mater Eng; 2001; 11(1):23-35. PubMed ID: 11281576
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Radiation and chemical crosslinking promote strain hardening behavior and molecular alignment in ultra high molecular weight polyethylene during multi-axial loading conditions.
    Kurtz SM; Pruitt LA; Jewett CW; Foulds JR; Edidin AA
    Biomaterials; 1999 Aug; 20(16):1449-62. PubMed ID: 10458558
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The wear of cross-linked polyethylene against itself.
    Joyce TJ; Ash HE; Unsworth A
    Proc Inst Mech Eng H; 1996; 210(1):11-6. PubMed ID: 8663888
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical wear behaviour of ultra-high molecular weight polyethylene cups paired with metal and ceramic ball heads in comparison to metal-on-metal pairings of hip joint replacements.
    Semlitsch M; Willert HG
    Proc Inst Mech Eng H; 1997; 211(1):73-88. PubMed ID: 9141893
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of head size on wear properties of metal-on-metal bearings of hip prostheses, and comparison with wear properties of metal-on-polyethylene bearings using hip simulator.
    Okazaki Y
    J Mech Behav Biomed Mater; 2014 Mar; 31():152-63. PubMed ID: 24290355
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The influence of molecular weight, crosslinking and counterface roughness on TNF-alpha production by macrophages in response to ultra high molecular weight polyethylene particles.
    Ingram JH; Stone M; Fisher J; Ingham E
    Biomaterials; 2004 Aug; 25(17):3511-22. PubMed ID: 15020125
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene. A hip-simulator study.
    McKellop H; Shen FW; Lu B; Campbell P; Salovey R
    J Bone Joint Surg Am; 2000 Dec; 82(12):1708-25. PubMed ID: 11130644
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of molecular weight, calcium stearate, and sterilization methods on the wear of ultra high molecular weight polyethylene acetabular cups in a hip joint simulator.
    McKellop HA; Shen FW; Campbell P; Ota T
    J Orthop Res; 1999 May; 17(3):329-39. PubMed ID: 10376720
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.