These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

96 related articles for article (PubMed ID: 6527073)

  • 21. [Plethysmography in venous pathology].
    Aelvoet G
    Phlebologie; 1983; 36(4):413-8. PubMed ID: 6657759
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Further assessment of the validity of the mercury strain gauge in measuring limb blood flow.
    Mengesha YA
    Ethiop Med J; 1977 Apr; 15(2):69-74. PubMed ID: 590261
    [No Abstract]   [Full Text] [Related]  

  • 23. [Computerized records in vascular pathology. V. Computer-assisted management of records in venous pathology].
    Boccalon H; Reggi M
    J Mal Vasc; 1986; 11(2):140-1. PubMed ID: 3522790
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Acute superficial thrombophlebitis--modern diagnosis and therapy].
    Marković MD; Lotina SI; Davidović LB; Vojnović BR; Kostić DM; Cinara IS; Svetković SD
    Srp Arh Celok Lek; 1997; 125(9-10):261-6. PubMed ID: 9340796
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Digital photoplethysmography and digital "strain-gauge" plethysmography in differential diagnosis of edema].
    Mlacak B; Budak A; Vrcić-Keglević M
    Lijec Vjesn; 1997 Jan; 119(1):32-7. PubMed ID: 9213729
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The reproducibility of limb blood flow measurements in human volunteers at rest and after exercise by using mercury-in-Silastic strain gauge plethysmography under standardized conditions.
    Roberts DH; Tsao Y; Breckenridge AM
    Clin Sci (Lond); 1986 Jun; 70(6):635-8. PubMed ID: 3709068
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Accuracy of strain-gauge plethysmography for the diagnosis of deep vein thrombosis.
    Bounameaux HM; Krähenbühl B
    Thromb Res; 1985 Feb; 37(3):487-8. PubMed ID: 3992530
    [No Abstract]   [Full Text] [Related]  

  • 28. Reproducibility of strain gauge venous occlusion plethysmography in long-run measurements in man.
    Romano S; Gizdulich P
    Methods Find Exp Clin Pharmacol; 1980 Apr; 2(2):83-7. PubMed ID: 7339333
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Venous occlusion plethysmography with mercury-in-rubber strain gauges.
    Raman ER; Delaruelle J; Vanhuyse VJ; Wolff HB
    Acta Anaesthesiol Belg; 1980; 31(1):5-14. PubMed ID: 7457043
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [The application of informatics to mercury gauge plethysmography].
    Barthel J; Locufier JL; Bosschaerts T; Barroy JP
    Phlebologie; 1989; 42(1):143-50. PubMed ID: 2755977
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A prospective follow-up study of acute deep venous thrombosis using colour duplex ultrasound, phlebography and venous occlusion plethysmography.
    Rosfors S; Eriksson M; Leijd B; Nordström E
    Int Angiol; 1997 Mar; 16(1):39-44. PubMed ID: 9165357
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Functional segmental plethysmography with mercury strain gauge.
    Sakaguchi S; Ishitobi K; Kameda T
    Angiology; 1972 Mar; 23(3):127-35. PubMed ID: 5018612
    [No Abstract]   [Full Text] [Related]  

  • 33. [Diagnosis of venous disease].
    Do DD; Husmann M
    Herz; 2007 Feb; 32(1):10-7. PubMed ID: 17323030
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Venous strain-gauge plethysmography--reference values.
    Akesson H; Brudin L
    Int Angiol; 1996 Sep; 15(3):268-71. PubMed ID: 8971590
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Noninvasive tests in the diagnosis of peripheral vascular disease.
    Osmundson PJ
    Cardiovasc Clin; 1980; 10(3):271-7. PubMed ID: 7379079
    [No Abstract]   [Full Text] [Related]  

  • 36. [Assessment of deep venous thrombosis].
    Z'Brun A; Do DD; Baumgartner I; Mahler F
    Ther Umsch; 1996 Apr; 53(4):258-64. PubMed ID: 8658347
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Current methods in the diagnosis of deep venous thrombosis of the lower limbs].
    Cappeliez O; Peetrons P; Creteur V
    Rev Med Brux; 1996 Jun; 17(3):127-31. PubMed ID: 8766583
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Noninvasive detection of thrombosis of the deep veins of the legs: comparison of Doppler ultrasonography and impedance plethysmography with venography.
    Elbaum DM; Wolfson PM; Hedlund D; Smith CR; Braunstein DB; Haspel LU; Litchfield RL; Sallen MK; Siegel MS
    J Am Osteopath Assoc; 1982 Apr; 81(8):535-40. PubMed ID: 7076528
    [No Abstract]   [Full Text] [Related]  

  • 39. Effect of varicose vein surgery on venous reflux scoring and plethysmographic assessment of venous function.
    Volkmann E; Falk A; Holm J; Philipson B; Risberg B; Volkmann R
    Eur J Vasc Endovasc Surg; 2008 Dec; 36(6):731-7. PubMed ID: 18675561
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Sequelae of unilateral deep venous thrombosis in plethysmography of the calf].
    Zicot M; Depairon M
    J Mal Vasc; 1982; 7(3):205-8. PubMed ID: 7142824
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.