These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

90 related articles for article (PubMed ID: 6530445)

  • 1. Clinical applications of the rapid high-performance liquid chromatographic determination of serum cortisol.
    Loche S; Porcelli F; Rosen M; Feffer M; Stoner E; New MI
    J Chromatogr; 1984 Dec; 317():377-82. PubMed ID: 6530445
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Simultaneous determination of serum cortisol and cortisone by reversed-phase liquid chromatography with ultraviolet detection.
    Volin P
    J Chromatogr; 1992 Dec; 584(2):147-55. PubMed ID: 1484099
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Improved liquid chromatographic determination of serum cortisol with double internal standardization compared to radioimmunoassay and fluorometry, and evaluated by isotope dilution/mass spectrometry.
    Lambert WE; De Slypere JP; Jonckheere JA; Vermeulen A; De Leenheer AP
    Anal Biochem; 1983 Oct; 134(1):216-23. PubMed ID: 6362481
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Improved liquid-chromatographic method for determination of serum cortisol.
    Kabra PM; Tsai LL; Marton LJ
    Clin Chem; 1979 Jul; 25(7):1293-6. PubMed ID: 455651
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [High performance liquid chromatography and radioimmunoassay in analysis of serum hydrocortisone concentration and pharmacokinetic parameters of glucocorticoids in human. The choice of method for clinical practice].
    Chekalin AF; Rossokhin VF; Nesterov SL; Kazanskiĭ AS; Salmin AA; Shishkanov SF; Kazakova MA; Kozlova EM; Eliseeva MV; Sedyshev VI
    Klin Lab Diagn; 2002 May; (5):20-3. PubMed ID: 12085700
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Liquid chromatography and radioimmunoassay compared for determination of cortisol and corticosterone in plasma after a dexamethasone suppression test.
    Oka K; Noguchi M; Kitamura T; Shima S
    Clin Chem; 1987 Sep; 33(9):1639-42. PubMed ID: 3621564
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of plasma and urinary cortisol by high-performance liquid chromatography using fluorescence derivatization with dansyl hydrazine.
    Kawasaki T; Maeda M; Tsuji A
    J Chromatogr; 1979 Jun; 163(2):143-50. PubMed ID: 541365
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Determination of cortisol and associated glucocorticoids in serum and urine by an automated liquid chromatographic assay.
    Samaan GJ; Porquet D; Demelier JF; Biou D
    Clin Biochem; 1993 Jun; 26(3):153-8. PubMed ID: 8330384
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reliability of the estimation of serum cortisol by high-performance liquid chromatography.
    Schöneshöfer M; Skobolo R; Dulce HJ
    J Chromatogr; 1981 Mar; 222(3):478-81. PubMed ID: 7228957
    [No Abstract]   [Full Text] [Related]  

  • 10. Solid-state extraction of cortisol from plasma or serum for liquid chromatography.
    Hofreiter BT; Mizera AC; Allen JP; Masi AM; Hicok WC
    Clin Chem; 1983 Oct; 29(10):1808-9. PubMed ID: 6616827
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Specific and practicable assessment of urinary free cortisol by combination of automatic high-pressure liquid chromatography and radioimmunoassay.
    Schöneshöfer M; Fenner A; Altinok G; Dulce HJ
    Clin Chim Acta; 1980 Sep; 106(1):63-73. PubMed ID: 7408209
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Automated direct high-performance liquid chromatographic assay for estetrol, estriol, cortisone and cortisol in serum and amniotic fluid.
    Noma J; Hayashi N; Sekiba K
    J Chromatogr; 1991 Jul; 568(1):35-44. PubMed ID: 1770108
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Semi-automated high-performance liquid chromatographic method for the simultaneous assay of plasma cortisol and 11-deoxycortisol in the metyrapone test.
    Underwood RH; Bradwin GR; Moore TJ; Williams GH
    J Chromatogr; 1990 Mar; 526(1):180-5. PubMed ID: 2341530
    [No Abstract]   [Full Text] [Related]  

  • 14. Quality control in the determination of cortisol in plasma/serum by using, on every sample, two different three-step separation methods including ultrafiltration, restricted-access high-performance liquid chromatography and reversed-phase high-performance liquid chromatography, and contrasting results to immunoassays.
    Mueller HW; Eitel J
    J Chromatogr B Biomed Appl; 1996 Apr; 678(2):137-50. PubMed ID: 8738015
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Preparation and development of solid phase radioimmunoassay system for determination of cortisol.
    Sallam KM
    J Immunoassay Immunochem; 2017; 38(5):471-486. PubMed ID: 28537478
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Determination of free cortisol in urine by high-pressure liquid chromatography (author's transl)].
    Schwedt G; Bussemas HH; Lippmann C
    J Chromatogr; 1977 May; 143(3):259-66. PubMed ID: 863981
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of urinary free cortisol by high performance liquid chromatography with sulphuric acid-ethanol derivatization and column switching.
    Nozaki O; Ohata T; Ohba Y; Moriyama H; Kato Y
    Biomed Chromatogr; 1992; 6(3):109-14. PubMed ID: 1525482
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Simultaneous determination of prednisolone and cortisol in serum by HPLC and by isotope dilution--mass spectrometry.
    Ost L; Falk O; Lantto O; Björkhem I
    Scand J Clin Lab Invest; 1982 Apr; 42(2):181-7. PubMed ID: 7134801
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The estimation of 6 beta-hydroxycortisol in urine -- a comparison of two methods: high performance liquid chromatography and radioimmunoassay.
    Gerber-Taras E; Park BK; Ohnhaus EE
    J Clin Chem Clin Biochem; 1981 Aug; 19(8):525-7. PubMed ID: 7276837
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Simultaneous determination of betamethasone, betamethasone acetate and hydrocortisone in biological fluids using high-performance liquid chromatography.
    Petersen MC; Nation RL; Ashley JJ
    J Chromatogr; 1980 Aug; 183(2):131-9. PubMed ID: 7400271
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.