These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

186 related articles for article (PubMed ID: 6533621)

  • 1. Measurement of radiation from photochemotherapy equipment using thermoluminescence detector elements (BeO TLD).
    Caccialanza M; Eulisse G; Farini L; Torresin A; Docchio F; Contini D
    Photodermatol; 1984 Dec; 1(6):298-301. PubMed ID: 6533621
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Investigation of a BeO-based optically stimulated luminescence dosemeter.
    Sommer M; Henniger J
    Radiat Prot Dosimetry; 2006; 119(1-4):394-7. PubMed ID: 16735572
    [TBL] [Abstract][Full Text] [Related]  

  • 3. OSL and TL techniques combined in a beryllium oxide detector to evaluate simultaneously accumulated and single doses.
    Malthez ALMC; Freitas MB; Yoshimura EM; Umisedo NK; Button VLSN
    Appl Radiat Isot; 2016 Apr; 110():155-159. PubMed ID: 26784853
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparative study on the susceptibility of LiF:Mg,Ti (TLD-100) and LiF:Mg,Cu,P (TLD-100H) to spurious signals in thermoluminescence dosimetry.
    Al-Haj A; Lagarde C; Mahyoub F
    Radiat Prot Dosimetry; 2007; 125(1-4):399-402. PubMed ID: 17223633
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison on characteristics of radiophotoluminescent glass dosemeters and thermoluminescent dosemeters.
    Hsu SM; Yeh SH; Lin MS; Chen WL
    Radiat Prot Dosimetry; 2006; 119(1-4):327-31. PubMed ID: 16709718
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [EPR and TL measurements of BeO "Termalox 995" irradiated with photons].
    Azzoni CB; Giroletti E; Rovera S
    Radiol Med; 1985; 71(7-8):521-4. PubMed ID: 3001845
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Microdosimetric modelling of the response of thermoluminescence detectors to low- and high-LET ionising radiation.
    Olko P; Bilski P; Budzanowski M; Czopyk L; Swakon J; Waligorski MP
    Radiat Prot Dosimetry; 2006; 122(1-4):378-81. PubMed ID: 17261540
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The dose-response of Harshaw TLD-700H.
    Velbeck KJ; Luo LZ; Ramlo MJ; Rotunda JE
    Radiat Prot Dosimetry; 2006; 119(1-4):255-8. PubMed ID: 16581931
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Thermoluminescence dosimetry and its applications in medicine--Part 1: Physics, materials and equipment.
    Kron T
    Australas Phys Eng Sci Med; 1994 Dec; 17(4):175-99. PubMed ID: 7872900
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The thermoluminescence dose-response and other characteristics of the high-temperature TL in LiF:Mg,Ti (TLD-100).
    Horowitz YS; Oster L; Datz H
    Radiat Prot Dosimetry; 2007; 124(2):191-205. PubMed ID: 17616543
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Description of modular devices for the measurement of external dosimetry in radiation protection.
    Genicot JL; Boogers E; Van Iersel M
    Radiat Prot Dosimetry; 2015 Apr; 164(3):194-202. PubMed ID: 25236335
    [TBL] [Abstract][Full Text] [Related]  

  • 12. On the relationship between dose-, energy- and LET-response of thermoluminescent detectors.
    Olko P; Bilski P; El-Faramawy NA; Göksu HY; Kim JL; Kopec R; Waligórski MP
    Radiat Prot Dosimetry; 2006; 119(1-4):15-22. PubMed ID: 16644968
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Defect analysis in natural quartz from Brazilian sites for ionising radiation dosimetry.
    Guzzo PL; Khoury HJ; Souza CP; Souza AM; Schwartz MO; Azevedo WM
    Radiat Prot Dosimetry; 2006; 119(1-4):168-71. PubMed ID: 16644986
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparative study of LiF:Mg,Cu,Na,Si and Li2B4O7:Cu,Ag,P TL detectors.
    Miljanić S; Ranogajec-Komor M; Knezević Z; Stuhec M; Prokić M
    Radiat Prot Dosimetry; 2006; 119(1-4):191-6. PubMed ID: 16709712
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Study of a method based on TLD detectors for in-phantom dosimetry in BNCT.
    Gambarini G; Klamert V; Agosteo S; Birattari C; Gay S; Rosi G; Scolari L
    Radiat Prot Dosimetry; 2004; 110(1-4):631-6. PubMed ID: 15353721
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Further studies in the reduction of residual in Harshaw TLD-100H (LiF:Mg,Cu,P).
    Ramlo M; Moscovitch M; Rotunda JE
    Radiat Prot Dosimetry; 2007; 125(1-4):217-9. PubMed ID: 17416592
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [The measurement of the characteristics of x-ray radiation generated by video display terminals by using thermoluminescent detectors].
    Kalmykov LZ
    Gig Tr Prof Zabol; 1992; (5):44-7. PubMed ID: 1427356
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The efficiency of various thermoluminescence dosemeter types to heavy ions.
    Berger T; Hajek M; Summerer L; Fugger M; Vana N
    Radiat Prot Dosimetry; 2006; 120(1-4):365-8. PubMed ID: 16731690
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comments on 'The thermoluminescence dose-response and other characteristics of the high-temperature TL in LiF: Mg.Ti (TLD-100)' by Y.S. Horowitz, L. Oster and H. Datz.
    German U; Weinstein M; Abraham A; Alfassi ZB
    Radiat Prot Dosimetry; 2008; 128(4):509-10; author reply 510-5. PubMed ID: 18420571
    [No Abstract]   [Full Text] [Related]  

  • 20. On-board TLD measurements on MIR and ISS.
    Deme S; Apáthy I; Pázmándi T; Benton ER; Reitz G; Akatov Y
    Radiat Prot Dosimetry; 2006; 120(1-4):438-41. PubMed ID: 16709717
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.