These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
74 related articles for article (PubMed ID: 6536542)
1. Evaluation of micro-sampling of blood by filter paper strips for malaria seroepidemiology. Srinivasa H; Bhat P Indian J Malariol; 1984 Dec; 21(2):127-9. PubMed ID: 6536542 [No Abstract] [Full Text] [Related]
2. Filter paper sampling methodology of whole blood cyclosporine (WBCyA) concentration: a critical review. Foradori AC; Loveluck A; Correa L Transplant Proc; 1990 Jun; 22(3):1226-30. PubMed ID: 2349684 [No Abstract] [Full Text] [Related]
3. Optimization of the blood sample filter paper technique for cyclosporine determination. Manrique RV; Lin HT Transplant Proc; 1990 Jun; 22(3):1231-3. PubMed ID: 2349685 [No Abstract] [Full Text] [Related]
4. Performance properties of filter paper devices for whole blood collection. Mei JV; Zobel SD; Hall EM; De Jesús VR; Adam BW; Hannon WH Bioanalysis; 2010 Aug; 2(8):1397-403. PubMed ID: 21083340 [TBL] [Abstract][Full Text] [Related]
5. A simple modified method of collecting blood on filter paper for anti-HTV test in seroepidemiological studies on nasopharyngeal carcinoma. Takada M; Murata M; Goto A; Kawamura A; Hung MH Jpn J Exp Med; 1970 Oct; 40(5):391-4. PubMed ID: 4927176 [No Abstract] [Full Text] [Related]
6. Evaluation of filter paper eluates for seroepidemiological studies on malaria in peninsular Malaysia. Thomas V; Chan WC Trop Geogr Med; 1982 Jun; 34(2):145-9. PubMed ID: 6750883 [No Abstract] [Full Text] [Related]
7. Storage stability of dengue IgM and IgG antibodies in whole blood and serum dried on filter paper strips detected by ELISA. Ruangturakit S; Rojanasuphot S; Srijuggravanvong A; Duangchanda S; Nuangplee S; Igarashi A Southeast Asian J Trop Med Public Health; 1994 Sep; 25(3):560-4. PubMed ID: 7777926 [TBL] [Abstract][Full Text] [Related]
8. The feasibility of filter paper collected blood for the serodiagnosis of malaria. Pérez HA; Bolívar J Mem Inst Oswaldo Cruz; 1989; 84(4):587-8. PubMed ID: 2487457 [No Abstract] [Full Text] [Related]
9. A dried blood sample on filter paper is suitable for detecting Plasmodium falciparum gametocytes by reverse transcription polymerase chain reaction. Maeno Y; Nakazawa S; Dao le D; Yamamoto N; Giang ND; Van Hanh T; Thuan le K; Taniguchi K Acta Trop; 2008 Aug; 107(2):121-7. PubMed ID: 18554563 [TBL] [Abstract][Full Text] [Related]
10. A simple method for collecting measured whole blood with quantitative recovery of antibody activities for serological surveys. Handali S; Rodriguez S; Noh J; Gonzalez AE; Garcia HH; Gilman RH; Roberts JM; Hancock K; Tsang VC J Immunol Methods; 2007 Mar; 320(1-2):164-71. PubMed ID: 17270207 [TBL] [Abstract][Full Text] [Related]
12. The use of filter paper as a transport medium for blood and serum. A comparative serological investigation. Oppelaar L Trop Geogr Med; 1966 Mar; 18(1):60-6. PubMed ID: 5957118 [No Abstract] [Full Text] [Related]
13. Recovery of HIV antibodies in eluates from plasma and erythrocytes dried on filter paper and stored under various conditions. van den Akker R; Kooy H; van der Meyden HP; Lumey BH AIDS; 1990 Jan; 4(1):90-1. PubMed ID: 2317311 [No Abstract] [Full Text] [Related]
14. Comparison of IsoCode STIX and FTA Gene Guard collection matrices as whole-blood storage and processing devices for diagnosis of malaria by PCR. Zhong KJ; Salas CJ; Shafer R; Gubanov A; Gasser RA; Magill AJ; Forney JR; Kain KC J Clin Microbiol; 2001 Mar; 39(3):1195-6. PubMed ID: 11230458 [TBL] [Abstract][Full Text] [Related]
15. An evaluation of Plasmodium cynomolgi bastianellii and Plasmodium knowlesi antigens in the seroepidemiology of human malaria using indirect haemagglutination test. Nath A; Srivastava IK; Sinha R; Agarwal SS; Dutta GP Indian J Malariol; 1984 Dec; 21(2):99-104. PubMed ID: 6536544 [No Abstract] [Full Text] [Related]
16. Filter paper collection of plasma for IGF-I test in patients with acromegaly. Wu TJ; Yu EH; Song L; Taylor RL; Kao PC Ann Clin Lab Sci; 2002; 32(3):287-91. PubMed ID: 12175092 [TBL] [Abstract][Full Text] [Related]
17. Validation of a new arterial micro sampling device. Cohill JD; White FK Respir Care; 1982 Oct; 27(10):1210-4. PubMed ID: 10315312 [TBL] [Abstract][Full Text] [Related]
18. [Filter paper sampling for the detection of anti-hepatitis A IgM antibodies]. Rodríguez Lay LA; Ribas Antúnez MA; Díaz Mendiondo B; Roque Quintero A; Aragón Rodríguez U; Martínez Casanueva R; Rodríguez Valdés C Rev Cubana Med Trop; 1998; 50(1):42-7. PubMed ID: 9842267 [TBL] [Abstract][Full Text] [Related]
19. [Comparison of the results of indirect immunofluorescence reactions performed in the diagnosis of malaria using blood samples collected on filter paper and in capillary tubes]. Wanderley DM; de Carvalho ME; Ferreira CS; Massucato MA; Tognoli SP Rev Bras Malariol Doencas Trop; 1982; 34():87-92. PubMed ID: 6764954 [No Abstract] [Full Text] [Related]
20. [Detection of malaria antibodies with micro-ELISA]. Wang J; Han M; Bao YF; Qu J; Zhang Y Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 1982 Oct; 4(5):319-21. PubMed ID: 6219770 [No Abstract] [Full Text] [Related] [Next] [New Search]