These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
115 related articles for article (PubMed ID: 6539219)
21. Point-of-care glucose testing in the neonatal intensive care unit is facilitated by the use of the Ames Glucometer Elite electrochemical glucose meter. Innanen VT; DeLand ME; deCampos FM; Dunn MS J Pediatr; 1997 Jan; 130(1):151-5. PubMed ID: 9003866 [TBL] [Abstract][Full Text] [Related]
22. Clinical application of a new glucose analyzer in the neonatal intensive care unit: comparison with other methods. Conrad PD; Sparks JW; Osberg I; Abrams L; Hay WW J Pediatr; 1989 Feb; 114(2):281-7. PubMed ID: 2915288 [TBL] [Abstract][Full Text] [Related]
23. Intra-operative blood glucose measurements. The effect of haematocrit on glucose test strips. Smith EA; Kilpatrick ES Anaesthesia; 1994 Feb; 49(2):129-32. PubMed ID: 8129121 [TBL] [Abstract][Full Text] [Related]
24. [Blood-sugar determination with the Reflomat (author's transl)]. Sommer R; Herbinger W Dtsch Med Wochenschr; 1975 Aug; 100(34):1697-701. PubMed ID: 1157662 [TBL] [Abstract][Full Text] [Related]
25. [Comparison of the blood glucose levels obtained by the Reflomat-Glucose-Reflotest and the orthotoluidine method]. De La Morena García E; García Lomas Pico LA; Salas Salas FJ; Cantero García-Arenal L Rev Clin Esp; 1980 Mar; 156(6):403-5. PubMed ID: 7394218 [No Abstract] [Full Text] [Related]
26. [A simple and quick method for measuring low blood-glucose concentrations (author's transl)]. Bürgi W; Hohenwallner W; Sommer R; Banauch D Dtsch Med Wochenschr; 1978 Nov; 103(46):1835-9. PubMed ID: 710305 [TBL] [Abstract][Full Text] [Related]
27. HemoCue beta-glucose photometer evaluated for use in a neonatal intensive care unit. Vadasdi E; Jacobs E Clin Chem; 1993 Nov; 39(11 Pt 1):2329-32. PubMed ID: 8222230 [TBL] [Abstract][Full Text] [Related]
28. [Blood glucose determination using the reflectometric Dextrostix method]. Brzezińska-Drygieniec D Pol Tyg Lek; 1973 Aug; 28(33):1276-7. PubMed ID: 4742299 [No Abstract] [Full Text] [Related]
29. Comparison of two strip test methods of whole blood glucose measurement in the neonatal period. Papp M; Sharief N Acta Paediatr; 2001 Sep; 90(9):1042-6. PubMed ID: 11683193 [TBL] [Abstract][Full Text] [Related]
30. A comparison study of blood glucose test strips. Worth RC; Harrison K; Anderson J; Johnston DG; Alberti KG Diabetes Care; 1981; 4(3):407-11. PubMed ID: 7344888 [TBL] [Abstract][Full Text] [Related]
31. Accuracy of four methods of home blood glucose monitoring in hemodialysis patients. Vanden Bosch MA; Hyneck ML Clin Pharm; 1984; 3(3):291-4. PubMed ID: 6734091 [TBL] [Abstract][Full Text] [Related]
32. The inaccuracy of venous and capillary blood glucose measurement using reagent strips in the newborn period and the effect of haematocrit. Hussain K; Sharief N Early Hum Dev; 2000 Feb; 57(2):111-21. PubMed ID: 10735458 [TBL] [Abstract][Full Text] [Related]
33. The effect of haematocrit and sample temperature on the Glucotide/Glucometer 4 blood glucose assay system. Wiener K Diabet Med; 1995 Apr; 12(4):362-3. PubMed ID: 7600755 [No Abstract] [Full Text] [Related]
34. Effect of hematocrit on accuracy of two point-of-care glucometers for use in dogs. Paul AE; Shiel RE; Juvet F; Mooney CT; Mansfield CS Am J Vet Res; 2011 Sep; 72(9):1204-8. PubMed ID: 21879978 [TBL] [Abstract][Full Text] [Related]
35. Factors affecting efficacy of packed red blood cell transfusion in neonates. Pilania RK; Saini SS; Dutta S; Das R; Marwaha N; Kumar P Eur J Pediatr; 2017 Jan; 176(1):67-74. PubMed ID: 27864631 [TBL] [Abstract][Full Text] [Related]
36. Dextrostix-Eyetone in the insulin hypoglycaemia test. Preece MA; Newall RG Br Med J; 1977 Jul; 2(6080):152-4. PubMed ID: 871822 [TBL] [Abstract][Full Text] [Related]
37. [Blood sugar determination in reflectometric evaluation of dextrostix stripes]. Bottermann P Verh Dtsch Ges Inn Med; 1972; 78():1256-9. PubMed ID: 4665511 [No Abstract] [Full Text] [Related]
38. The effects of precision, haematocrit, pH and oxygen tension on point-of-care glucose measurement in critically ill patients: a prospective study. Watkinson PJ; Barber VS; Amira E; James T; Taylor R; Young JD Ann Clin Biochem; 2012 Mar; 49(Pt 2):144-51. PubMed ID: 22349553 [TBL] [Abstract][Full Text] [Related]
39. Laboratory staff and nurses' performance compared when using the blood glucose Reflotest-Reflomat system. Smith JH Med Lab Sci; 1983 Jul; 40(3):283-5. PubMed ID: 6621275 [No Abstract] [Full Text] [Related]