These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

178 related articles for article (PubMed ID: 6544773)

  • 1. Direct electron microscopy studies of the bone-hydroxylapatite interface.
    Tracy BM; Doremus RH
    J Biomed Mater Res; 1984 Sep; 18(7):719-26. PubMed ID: 6544773
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Differences in ceramic-bone interface between surface-active ceramics and resorbable ceramics: a study by scanning and transmission electron microscopy.
    Neo M; Kotani S; Fujita Y; Nakamura T; Yamamuro T; Bando Y; Ohtsuki C; Kokubo T
    J Biomed Mater Res; 1992 Feb; 26(2):255-67. PubMed ID: 1569117
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Tissue, cellular and subcellular events at a bone-ceramic hydroxylapatite interface.
    Jarcho M; Kay JF; Gumaer KI; Doremus RH; Drobeck HP
    J Bioeng; 1977 Jan; 1(2):79-92. PubMed ID: 355244
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparative study of ultrastructures of the interfaces between four kinds of surface-active ceramic and bone.
    Neo M; Kotani S; Nakamura T; Yamamuro T; Ohtsuki C; Kokubo T; Bando Y
    J Biomed Mater Res; 1992 Nov; 26(11):1419-32. PubMed ID: 1447227
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Two-dimensional and 3-dimensional analysis of bone/dental implant interfaces with the use of focused ion beam and electron microscopy.
    Giannuzzi LA; Phifer D; Giannuzzi NJ; Capuano MJ
    J Oral Maxillofac Surg; 2007 Apr; 65(4):737-47. PubMed ID: 17368372
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [The interface between hydroxyapatite ceramic and newly formed bone in scanning electron microscopy].
    Brill W; Katthagen BD
    Z Orthop Ihre Grenzgeb; 1987; 125(2):183-7. PubMed ID: 3039750
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Interface mechanics and histomorphometric analysis of hydroxyapatite-coated and porous glass-ceramic implants in canine bone.
    Nimb L; Jensen JS; Gotfredsen K
    J Biomed Mater Res; 1995 Dec; 29(12):1477-82. PubMed ID: 8600137
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A technique for the preparation of cross-sectional TEM samples of ZnSe/GaAs heterostructures which eliminates process-induced defects.
    Yu JE; Jones KS; Park RM
    J Electron Microsc Tech; 1991 Jul; 18(3):315-24. PubMed ID: 1880604
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Mechanisms and structure of the bond between bone and hydroxyapatite ceramics.
    Bagambisa FB; Joos U; Schilli W
    J Biomed Mater Res; 1993 Aug; 27(8):1047-55. PubMed ID: 8408117
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Initial bone matrix formation at the hydroxyapatite interface in vivo.
    de Bruijn JD; van Blitterswijk CA; Davies JE
    J Biomed Mater Res; 1995 Jan; 29(1):89-99. PubMed ID: 7713963
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The influence of compositional variations on bone ingrowth of implanted porous calcium aluminate ceramics.
    Graves GA; Noyes FR; Villanueva AR
    J Biomed Mater Res; 1975 Jul; 9(4):17-22. PubMed ID: 809446
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effect of hydrofluoric acid surface treatment and bond strength of a zirconia veneering ceramic.
    Chaiyabutr Y; McGowan S; Phillips KM; Kois JC; Giordano RA
    J Prosthet Dent; 2008 Sep; 100(3):194-202. PubMed ID: 18762031
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of interface characterization and adhesion of glass ceramics to commercially pure titanium and gold alloy after thermal- and mechanical-loading.
    Vásquez VZ; Ozcan M; Kimpara ET
    Dent Mater; 2009 Feb; 25(2):221-31. PubMed ID: 18718654
    [TBL] [Abstract][Full Text] [Related]  

  • 14. TEM investigation of nanophase aluminum powder.
    Gertsman VY; Kwok QS
    Microsc Microanal; 2005 Oct; 11(5):410-20. PubMed ID: 17481322
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Tissue response to dense apatite implants in rats.
    Denissen HW; de Groot K; Makkes PC; van den Hooff A; Klopper PJ
    J Biomed Mater Res; 1980 Nov; 14(6):713-21. PubMed ID: 7052204
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ultrastructural features of the bone response to a plasma-sprayed hydroxyapatite coating in sheep.
    Hemmerlé J; Onçag A; Ertürk S
    J Biomed Mater Res; 1997 Sep; 36(3):418-25. PubMed ID: 9260113
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Oxidized titanium screws coated with calcium ions and their performance in rabbit bone.
    Sul YT; Johansson CB; Albrektsson T
    Int J Oral Maxillofac Implants; 2002; 17(5):625-34. PubMed ID: 12381062
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Osteogenesis at the dental implant interface: high-voltage electron microscopic and conventional transmission electron microscopic observations.
    Steflik DE; Sisk AL; Parr GR; Gardner LK; Hanes PJ; Lake FT; Berkery DJ; Brewer P
    J Biomed Mater Res; 1993 Jun; 27(6):791-800. PubMed ID: 8408109
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Advances in the ultrastructural study of the implant-bone interface by backscattered electron imaging.
    Wierzchos J; Falcioni T; Kiciak A; Woliński J; Koczorowski R; Chomicki P; Porembska M; Ascaso C
    Micron; 2008 Dec; 39(8):1363-70. PubMed ID: 18337110
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Preparation of cross-sectional specimens of ceramic thermal barrier coatings for transmission electron microscopy.
    Unal O; Heuer AH; Mitchell TE
    J Electron Microsc Tech; 1990 Apr; 14(4):307-12. PubMed ID: 2332805
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.