These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
96 related articles for article (PubMed ID: 6549490)
1. In vivo investigation of a new elastomeric vascular graft (Mitrathane). Ives CL; Zamora JL; Eskin SG; Weilbaecher DG; Gao ZR; Noon GP; DeBakey ME Trans Am Soc Artif Intern Organs; 1984; 30():587-90. PubMed ID: 6549490 [No Abstract] [Full Text] [Related]
2. Series shunt evaluation of polyurethane vascular graft materials in chronically AV-shunted canines. McCoy TJ; Wabers HD; Cooper SL J Biomed Mater Res; 1990 Jan; 24(1):107-29. PubMed ID: 2303499 [TBL] [Abstract][Full Text] [Related]
3. Anisotropic polyurethane nonwoven conduits: a new approach to the design of a vascular prosthesis. Wilson GJ; MacGregor DC; Klement P; Lee JM; del Nido PJ; Wong EW; Leidner J Trans Am Soc Artif Intern Organs; 1983; 29():260-8. PubMed ID: 6673236 [No Abstract] [Full Text] [Related]
4. In vivo evaluation of hydrophobic and fibrillar microporous polyetherurethane urea graft. Marois Y; Guidoin R; Boyer D; Assayed F; Doillon CJ; Paynter R; Marois M Biomaterials; 1989 Oct; 10(8):521-31. PubMed ID: 2605286 [TBL] [Abstract][Full Text] [Related]
5. A compliant Corethane/Dacron composite vascular prosthesis. Comparison with 4-mm ePTFE grafts in a canine model. Wilson GJ; MacGregor DC; Klement P; Weber BA; Binnington AG; Pinchuk L ASAIO J; 1993; 39(3):M526-31. PubMed ID: 8268591 [TBL] [Abstract][Full Text] [Related]
6. A Corethane/polyester composite vascular prosthesis for vascular access. Comparison with expanded polytetrafluoroethylene grafts in a canine model. Wilson GJ; MacGregor DC; Bridgeman J; Weber BA; Binnington AG; Pinchuk L ASAIO J; 1995; 41(3):M728-34. PubMed ID: 8573903 [TBL] [Abstract][Full Text] [Related]
7. The hydrolytic stability of Mitrathane (a polyurethane urea)--an x-ray photoelectron spectroscopy study. Paynter RW; Askill IN; Glick SH; Guidoin R J Biomed Mater Res; 1988 Aug; 22(8):687-98. PubMed ID: 3215906 [TBL] [Abstract][Full Text] [Related]
8. Mechanisms of vein graft failure: the location, distribution, and characteristics of lesions that predispose to graft failure. Mills JL Semin Vasc Surg; 1993 Jun; 6(2):78-91. PubMed ID: 8252238 [No Abstract] [Full Text] [Related]
9. A spun elastomeric graft for dialysis access. Drasler WJ; Wilson GJ; Stenoien MD; Jenson ML; George SA; Dutcher RG; Possis ZC ASAIO J; 1993; 39(2):114-9. PubMed ID: 8324257 [TBL] [Abstract][Full Text] [Related]
10. Mitrathane. A new polyether urethane urea for critical medical application. Gilding DK; Reed AM; Askill IN; Briana S Trans Am Soc Artif Intern Organs; 1984; 30():571-6. PubMed ID: 6549489 [No Abstract] [Full Text] [Related]
11. In vivo canine studies of a Sinkhole valve and vascular graft coated with biocompatible PU-PEO-SO3. Han DK; Lee KB; Park KD; Kim CS; Jeong SY; Kim YH; Kim HM; Min BG ASAIO J; 1993; 39(3):M537-41. PubMed ID: 8268593 [TBL] [Abstract][Full Text] [Related]
12. A new fibrin-containing, small-diameter arterial prosthesis. Soldani G; Palla M; Paci M; Giusti P; Parenti G; Marconi F; Marchetti G; Bianchi G; Simi V Life Support Syst; 1987; 5(1):9-12. PubMed ID: 3586711 [No Abstract] [Full Text] [Related]
13. Newly designed compliant hierarchic hybrid vascular graft wrapped with microprocessed elastomeric film--II: Morphogenesis and compliance change upon implantation. He H; Matsuda T Cell Transplant; 2002; 11(1):75-87. PubMed ID: 12095223 [TBL] [Abstract][Full Text] [Related]