These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

111 related articles for article (PubMed ID: 6581750)

  • 41. Inspired oxygen and Cape Bristol ventilators.
    Allt-Graham J; Hart BC
    Anaesthesia; 1979 Feb; 34(2):198-201. PubMed ID: 286561
    [TBL] [Abstract][Full Text] [Related]  

  • 42. An IMV setup without a compressed air source.
    Anderson EF; Behm RA
    Crit Care Med; 1977; 5(4):185-9. PubMed ID: 326484
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Use of air to maintain nitrogen stores during low flow and closed circuit anaesthesia.
    Stokes JW
    Anaesth Intensive Care; 1994 Aug; 22(4):391-3. PubMed ID: 7978202
    [No Abstract]   [Full Text] [Related]  

  • 44. Fresh gas flow and carbon dioxide rebreathing in a low pressure semi-open anaesthesia system.
    Tweed WA; Amatya R; Lekhak BD
    Can J Anaesth; 1993 Nov; 40(11):1096-101. PubMed ID: 8269574
    [TBL] [Abstract][Full Text] [Related]  

  • 45. The effect of a bellows leak in an Ohmeda 7810 ventilator on room contamination, inspired oxygen, airway pressure, and tidal volume.
    Lampotang S; Sanchez JC; Chen B; Gravenstein N
    Anesth Analg; 2005 Jul; 101(1):151-4, table of contents. PubMed ID: 15976223
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Functionally crossed pipelines. An intermittent condition by a faulty ventilator.
    Weightman WM; Fenton-May V; Saunders R; Lewis A; Wise CC
    Anaesthesia; 1992 Jun; 47(6):500-2. PubMed ID: 1616088
    [TBL] [Abstract][Full Text] [Related]  

  • 47. [The function of 100% O2 suction key in Bennett 7200 microprocessor ventilator].
    Bien MY; Liao SM; Wang JH
    Zhonghua Yi Xue Za Zhi (Taipei); 1990 Jan; 45(1):39-44. PubMed ID: 2168238
    [TBL] [Abstract][Full Text] [Related]  

  • 48. A combined oxygen concentrator and compressed air unit. Assessment of a prototype and discussion of its potential applications.
    Easy WR; Douglas GA; Merrifield AJ
    Anaesthesia; 1988 Jan; 43(1):37-41. PubMed ID: 3422791
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Hazard report. Defective oxygen supply tubing may delay use of some Allied EPV100 emergency portable ventilators.
    Health Devices; 2009 Dec; 38(12):415-6. PubMed ID: 21243912
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Potential hazard of East-Radcliffe ventilator. Failure to entrain adequate oxygen.
    Myerson KR
    Anaesthesia; 1985 Mar; 40(3):285-7. PubMed ID: 3887978
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Contamination of the medical air supply with oxygen: a clinical engineering incident investigation.
    Kane WE; Ridley JD; Sheehan MW; Klein GF
    J Clin Eng; 1990; 15(4):295-300. PubMed ID: 10105928
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Air-Oxygen Blenders for Mechanical Ventilators: A Literature Review.
    Soares GF; Almeida OM; Menezes JWM; Kozlov SSA; Rodrigues JJPC
    Sensors (Basel); 2022 Mar; 22(6):. PubMed ID: 35336353
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Prevention of accidents associated with air-oxygen mixers.
    Karmann U; Roth F
    Anaesthesia; 1982 Jun; 37(6):680-2. PubMed ID: 6953773
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Inaccuracies of nitric oxide delivery systems during adult mechanical ventilation.
    Imanaka H; Hess D; Kirmse M; Bigatello LM; Kacmarek RM; Steudel W; Hurford WE
    Anesthesiology; 1997 Mar; 86(3):676-88. PubMed ID: 9066335
    [TBL] [Abstract][Full Text] [Related]  

  • 55. [Failure of a OP25 O2/N2O proportion-limiting control system].
    Bergeron B; Delagranda Y
    Ann Fr Anesth Reanim; 1987; 6(1):74. PubMed ID: 3472478
    [No Abstract]   [Full Text] [Related]  

  • 56. A low-pressure portable anaesthesia system for field use: clinical trials.
    Tweed WA; Amatya R; Spoerel WE
    Can J Anaesth; 1990 Nov; 37(8):928-31. PubMed ID: 2147595
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Nitric oxide supplied from a 10% source provides inhaled therapy without lowering inspired oxygen fraction.
    Moon JK; Evey LW; Moon YS; Gest AL; Gomez MR; Wearden ME
    Biomed Instrum Technol; 1997; 31(2):164-8. PubMed ID: 9099438
    [TBL] [Abstract][Full Text] [Related]  

  • 58. USING THE AUTOMATED FIO2- SPO2 CONTROL IN NEONATAL INTENSIVE CARE UNITS IN POLAND. A PRELIMINARY REPORT.
    Wilińska M; Skrzypek M; Bachman T; Swietliński J; Kostuch M; Bierla K; Czyzewska M; Hajdar R; Warakomska M
    Dev Period Med; 2015; 19(3 Pt 1):263-70. PubMed ID: 26958688
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Connecting or disconnecting display during use can disrupt performance of Puritan-Bennett 7200 ventilator.
    Health Devices; 2002 Jun; 31(6):227-31. PubMed ID: 12116506
    [No Abstract]   [Full Text] [Related]  

  • 60. Monitoring ventilator function.
    Branson RD
    Crit Care Clin; 1995 Jan; 11(1):127-43. PubMed ID: 7736264
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.