These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

241 related articles for article (PubMed ID: 6599530)

  • 1. Nested control procedures for internal analytical quality control. Theoretical design and practical evaluation.
    Aronsson T; Groth T
    Scand J Clin Lab Invest Suppl; 1984; 172():51-64. PubMed ID: 6599530
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Principles for developing improved quality control procedures.
    Westgard JO; Groth T; de Verdier CH
    Scand J Clin Lab Invest Suppl; 1984; 172():19-41. PubMed ID: 6599521
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A quality control simulator for design and evaluation of internal quality control procedures.
    Groth T; Falk H; Westgard JO
    Scand J Clin Lab Invest Suppl; 1984; 172():195-201. PubMed ID: 6599523
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The quality-costs of an analytical process: 2. A test yield formulation of the predictive value quality-costs model.
    Westgard JO; Hyltoft Petersen P; Groth T
    Scand J Clin Lab Invest Suppl; 1984; 172():229-36. PubMed ID: 6599528
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The quality-costs of an analytical process: 1. Development of quality-costs models based on predictive value theory.
    Westgard JO; Hyltoft Petersen P; Groth T
    Scand J Clin Lab Invest Suppl; 1984; 172():221-7. PubMed ID: 6599527
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The impact of quality control materials on the performance of an internal quality control system: 2. Experiences from S-calcium analysis.
    Jørgensen PJ; Hørder M; Blaabjerg O; Hyltoft Petersen P; Haas V; Olsson V
    Scand J Clin Lab Invest Suppl; 1984; 172():71-7. PubMed ID: 6599532
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The impact of quality control materials on the performance of an internal quality control system: 1. General considerations.
    Hyltoft Petersen P; Hørder M; Blaabjerg O; Jørgensen PJ
    Scand J Clin Lab Invest Suppl; 1984; 172():65-9. PubMed ID: 6599531
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The quality assurance system in clinical chemistry.
    Albertini A; Signorini C
    Ann Ist Super Sanita; 1995; 31(1):3-8. PubMed ID: 8546372
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Computer systems for implementation of internal quality control procedures.
    Westgard JO; Groth T
    Scand J Clin Lab Invest Suppl; 1984; 172():203-7. PubMed ID: 6599524
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Internal quality control of hormone determinations by RIA. Detection of clinically significant analytical errors of serum thyroxine determination.
    Ruokonen A; Heikkilä J; Leskinen E; Nyberg A; Vihko R
    Scand J Clin Lab Invest Suppl; 1984; 172():93-9. PubMed ID: 6599535
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Multirule quality control procedures.
    Carey RN
    Ann Ist Super Sanita; 1991; 27(3):419-25. PubMed ID: 1809061
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Design and evaluation of statistical control procedures: applications of a computer "quality control simulator" program.
    Westgard JO; Groth T
    Clin Chem; 1981 Sep; 27(9):1536-45. PubMed ID: 7261331
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Specimen-dependent effects on the apparent analytical quality in surveys of Nordic clinical chemistry laboratories.
    Solberg HE; Skrede S
    Scand J Clin Lab Invest Suppl; 1984; 172():159-62. PubMed ID: 6599516
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Proposed guidelines for the internal quality control of analytical results in the medical laboratory.
    Petersen PH; Ricós C; Stöckl D; Libeer JC; Baadenhuijsen H; Fraser C; Thienpont L
    Eur J Clin Chem Clin Biochem; 1996 Dec; 34(12):983-99. PubMed ID: 8986407
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Monitoring long-term analytical quality by computerized combined Shewart-cusum method.
    Solberg HE
    Scand J Clin Lab Invest Suppl; 1984; 172():43-9. PubMed ID: 6599529
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Performance characteristics of rules for internal quality control: probabilities for false rejection and error detection.
    Westgard JO; Groth T; Aronsson T; Falk H; de Verdier CH
    Clin Chem; 1977 Oct; 23(10):1857-67. PubMed ID: 902411
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Internal quality control of prothrombin time in primary care: comparing the use of patient split samples with lyophilised control materials.
    Stavelin A; Petersen PH; Sølvik U; Sandberg S
    Thromb Haemost; 2009 Sep; 102(3):593-600. PubMed ID: 19718482
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [A model for evaluating internal accuracy].
    Salas R; López N; Loría A; Pasquetti A
    Rev Invest Clin; 2000; 52(6):654-64. PubMed ID: 11256109
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Physician office analyzers. Do they satisfy medically useful criteria for analytical performance of laboratory tests?
    Nanji AA; Poon R; Hinberg I
    Arch Pathol Lab Med; 1988 Jul; 112(7):757-9. PubMed ID: 3382331
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Data base management systems for evaluation of analytical procedures.
    Groth T; Larsson O; Aronsson T; de Verdier CH
    Scand J Clin Lab Invest Suppl; 1984; 172():209-13. PubMed ID: 6599525
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.