These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 660017)

  • 1. Effects of the volume conductor on the apparent orientation of a known cardiac dipole.
    Salu Y; Laughlin D; Rogers J; Marcus M
    J Electrocardiol; 1978 Apr; 11(2):143-6. PubMed ID: 660017
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A simulation study of the effects of torso inhomogeneities on electrocardiographic potentials, using realistic heart and torso models.
    Gulrajani RM; Mailloux GE
    Circ Res; 1983 Jan; 52(1):45-56. PubMed ID: 6848209
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Electrocardiographic imaging: I. Effect of torso inhomogeneities on body surface electrocardiographic potentials.
    Ramanathan C; Rudy Y
    J Cardiovasc Electrophysiol; 2001 Feb; 12(2):229-40. PubMed ID: 11232624
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Applicability of the single equivalent moving dipole model in an infinite homogeneous medium to identify cardiac electrical sources: a computer simulation study in a realistic anatomic geometry torso model.
    Fukuoka Y; Oostendorp TF; Sherman DA; Armoundas AA
    IEEE Trans Biomed Eng; 2006 Dec; 53(12 Pt 1):2436-44. PubMed ID: 17153200
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An experimental study on the effect of the anisotropic regions in a realistically shaped torso phantom.
    Sengül G; Liehr M; Haueisen J; Baysal U
    Ann Biomed Eng; 2008 Nov; 36(11):1836-43. PubMed ID: 18759108
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Electrocardiographic imaging: II. Effect of torso inhomogeneities on noninvasive reconstruction of epicardial potentials, electrograms, and isochrones.
    Ramanathan C; Rudy Y
    J Cardiovasc Electrophysiol; 2001 Feb; 12(2):241-52. PubMed ID: 11232625
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Localization of cardiac ectopic activity in man by a single moving dipole. Comparison of different computation techniques.
    Savard P; Ackaoui A; Gulrajani RM; Nadeau RA; Roberge FA; Guardo R; Dube B
    J Electrocardiol; 1985 Jul; 18(3):211-21. PubMed ID: 4031724
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomagnetic localization of electrical current sources in the human heart with realistic volume conductors using the single-current-dipole model.
    Bruder H; Killmann R; Moshage W; Weismüller P; Achenbach S; Bömmel F
    Phys Med Biol; 1994 Apr; 39(4):655-68. PubMed ID: 15552076
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The canine heart as an electrocardiographic generator. Dependence on cardiac cell orientation.
    Corbin LV; Scher AM
    Circ Res; 1977 Jul; 41(1):58-67. PubMed ID: 862144
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Computer simulation of the precordial QRS complex: effects of simulated changes in ventricular wall thickness and volume.
    Salu Y; Marcus ML
    Am Heart J; 1976 Dec; 92(6):758-66. PubMed ID: 998483
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Simulation studies of the electrocardiogram. I. The normal heart.
    Miller WT; Geselowitz DB
    Circ Res; 1978 Aug; 43(2):301-15. PubMed ID: 668061
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of rotational myocardial anisotropy in forward potential computations with equivalent heart dipoles.
    Thivierge M; Gulrajani RM; Savard P
    Ann Biomed Eng; 1997; 25(3):477-98. PubMed ID: 9146803
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Torso coupling techniques for the forward problem of electrocardiography.
    Buist M; Pullan A
    Ann Biomed Eng; 2002; 30(10):1299-312. PubMed ID: 12540206
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Forward problem of electrocardiography: is it solved?
    Bear LR; Cheng LK; LeGrice IJ; Sands GB; Lever NA; Paterson DJ; Smaill BH
    Circ Arrhythm Electrophysiol; 2015 Jun; 8(3):677-84. PubMed ID: 25834182
    [TBL] [Abstract][Full Text] [Related]  

  • 15. On the biomagnetic inverse problem in the case of multiple dipoles.
    Lütkenhöner B; Lehnertz K; Hoke M; Pantev C
    Acta Otolaryngol Suppl; 1991; 491():94-104; discussion 105. PubMed ID: 1814161
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Magnetic localisation of a current dipole implanted in dogs.
    Costa Monteiro E; Bruno AC; Louro SR; Costa Ribeiro P; Fonseca Costa A
    Phys Med Biol; 1987 Jan; 32(1):65-70. PubMed ID: 3823141
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Manifest orientation: the theoretical link between the anatomy of the heart and the clinical electrocardiogram.
    Horan LG
    J Am Coll Cardiol; 1987 May; 9(5):1049-56. PubMed ID: 3571744
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Equivalent dipole sources to estimate the influence of extracellular myocardial anisotropy in thin-walled cardiac forward models.
    Jacquemet V
    Math Biosci; 2017 Apr; 286():31-38. PubMed ID: 28159543
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Determination of the locus of the heart vector from body surface measurements: model experiments.
    Nelson CV; Hodgkin BC; Voukydis PC
    J Electrocardiol; 1975; 8(2):135-46. PubMed ID: 1151194
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Part III: the effect of the torso boundaries on the magnetocardiogram.
    Hosaka H; Cohen D; Cuffin BN; Horacek BM
    J Electrocardiol; 1976; 9(4):418-25. PubMed ID: 978095
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.