These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 6603360)

  • 21. A technique for the preparation of Tc-99m red blood cells for evaluation of gastrointestinal hemorrhage.
    Benedetto AR; Nusynowitz ML
    Clin Nucl Med; 1983 Apr; 8(4):160-2. PubMed ID: 6303670
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effects of preloading of stannous compounds on the distribution of 99mTc-pertechnetate.
    Greenberg DD; Som P; Meinken GE; Sacker DF; Atkins HL
    Nuklearmedizin; 1977 Feb; 16(1):26-9. PubMed ID: 191793
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Localization of gastrointestinal hemorrhage-marking red blood cells in vivo and in vitro with 99mTc].
    Noguera E; Mothe G; Wyse E
    Medicina (B Aires); 1984; 44(4):397-401. PubMed ID: 6336192
    [No Abstract]   [Full Text] [Related]  

  • 24. Clinical value of sequential subtraction scintigraphy with 99mTc-RBC for gastrointestinal bleeding.
    Wu Y; Seto H
    Chin Med J (Engl); 2001 Jan; 114(1):69-72. PubMed ID: 11779440
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Technetium-99m labeling of red blood cells: in vitro evaluation of a new approach.
    Kelbaek H
    J Nucl Med; 1986 Nov; 27(11):1770-3. PubMed ID: 3772511
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Technetium-99m RBC bleeding images in normal subjects: confusion with gastrointestinal bleeding sites.
    Boyd CM; Williamson MR
    Clin Nucl Med; 1989 Mar; 14(3):202-9. PubMed ID: 2786790
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Evaluation of gastrointestinal bleeding by red blood cells labeled in vivo with technetium-99m.
    Winzelberg GG; McKusick KA; Strauss HW; Waltman AC; Greenfield AJ
    J Nucl Med; 1979 Oct; 20(10):1080-6. PubMed ID: 317093
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Combined 99mTc-sulfide colloid and 99mTc-RBC studies for localization of gastrointestinal bleeding sites.
    Chu DD; Lentle BC; Szasz IJ
    AJR Am J Roentgenol; 1989 Mar; 152(3):653-4. PubMed ID: 2783825
    [No Abstract]   [Full Text] [Related]  

  • 29. Increased genital uptake of 99mTc red blood cells: a potential cause of false-positive studies for gastrointestinal bleeding.
    Wahl RL; Lee ME
    Eur J Nucl Med; 1984; 9(5):245-6. PubMed ID: 6610553
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Scintigraphy of gastrointestinal hemorrhage: superiority of 99mTc red blood cells over 99mTc sulfur colloid.
    Bunker SR; Lull RJ; Tanasescu DE; Redwine MD; Rigby J; Brown JM; Brachman MB; McAuley RJ; Ramanna L; Landry A
    AJR Am J Roentgenol; 1984 Sep; 143(3):543-8. PubMed ID: 6331732
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Serial radionuclide determinations of the electron fraction with 99mTc-labeled red blood cells.
    Alderson PO; Bernier DR; Ludbrook PA; Harwig JF; Roberts R; Sobel BE
    Radiology; 1976 Jun; 119(3):729-30. PubMed ID: 935417
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Radionuclide localization of lower gastrointestinal hemorrhage.
    Winzelberg GG; Froelich JW; McKusick KA; Waltman AC; Greenfield AJ; Athanasoulis CA; Strauss HW
    Radiology; 1981 May; 139(2):465-9. PubMed ID: 6971455
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Poor labeling of Tc-99m red blood cells in vivo in a radionuclide intestinal bleeding study of a patient who had recently undergone frequent blood transfusions.
    Kawabe J; Higashiyama S; Torii K; Okamura T; Kotani J; Kawamura E; Ishizu H; Koyama K; Yamane T; Shiomi S
    Clin Nucl Med; 2003 Nov; 28(11):911-2. PubMed ID: 14578707
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Localization of obscure gastrointestinal bleeding by technetium 99m-labeled red blood cell scintigraphy.
    Wang CS; Tzen KY; Huang MJ; Wang JY; Chen MF
    J Formos Med Assoc; 1992 Jan; 91(1):63-8. PubMed ID: 1352337
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [The place of nuclear medicine procedures in clarifying the state of gastrointestinal bleeding--radionuclide monitoring].
    Schmidtchen M; Reichelt HG
    Rontgenblatter; 1990 Jun; 43(6):251-5. PubMed ID: 2196666
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Cardiac blood pool imaging--a clinical comparison between red blood cells labeled with 99mTc in vivo and in vitro and 99mTc-labeled human serum albumin.
    Dahlström JA; Carlsson S; Lilja B; Mattsson S; Pettersson C
    Nuklearmedizin; 1979; 18(6):271-3. PubMed ID: 537922
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Heparin as a pharmacologic intervention to induce positive scintiscan in occult gastrointestinal bleeding.
    Chaudhuri TK; Brantly M
    Clin Nucl Med; 1984 Apr; 9(4):187-8. PubMed ID: 6609790
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Scintigraphy using erythrocytes labeled in vivo with 99mTc. Detection of an intestinal hemorrhage following a duodenum-preserving resection of the pancreas head].
    Brecht-Krauss D; Schnarkowski P; Friedrich JM
    Rofo; 1990 Sep; 153(3):271-4. PubMed ID: 2171059
    [TBL] [Abstract][Full Text] [Related]  

  • 39. In vivo labeling of red blood cells with Tc-99m with stannous pyridoxylideneaminates.
    Kato M
    J Nucl Med; 1979 Oct; 20(10):1071-4. PubMed ID: 536758
    [TBL] [Abstract][Full Text] [Related]  

  • 40. 99mTc-labelled red blood cell scintigraphy for localization of gastrointestinal bleeding in chronic renal failure.
    Oliveras A; Aubia J; Cao H; Puig JM; Barbosa F; Mir M; Orfila A; Lloveras J; Masramon J
    Nephron; 1998 Sep; 80(1):76-8. PubMed ID: 9730709
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.