These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

212 related articles for article (PubMed ID: 6605065)

  • 1. Single-photon emission computed tomography of the normal liver.
    Carrasquillo JA; Rogers JV; Williams DL; Shuman WP; Olson DO; Larson SM
    AJR Am J Roentgenol; 1983 Nov; 141(5):937-41. PubMed ID: 6605065
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Single photon emission computed tomograms of the liver: normal vascular intrahepatic structures.
    Pettigrew RI; Witztum KF; Perkins GC; Johnson ML; Burks RN; Verba JW; Halpern SE
    Radiology; 1984 Jan; 150(1):219-23. PubMed ID: 6606191
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparison between 180 degrees and 360 degrees data reconstruction in single photon emission computed tomography of the liver and spleen.
    Ott RJ; Flower MA; Khan O; Kalirai T; Webb S; Leach MO; McCready VR
    Br J Radiol; 1983 Dec; 56(672):931-7. PubMed ID: 6606477
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Single-photon emission computerized tomography in the diagnosis of liver diseases].
    Sergienko VB; Babenkov NV; Ternovoĭ SK
    Ter Arkh; 1986; 58(3):73-6. PubMed ID: 3520926
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Lesion detection with single-photon emission computed tomography (SPECT) compared with conventional imaging.
    Jaszczak RJ; Whitehead FR; Lim CB; Coleman RE
    J Nucl Med; 1982 Feb; 23(2):97-102. PubMed ID: 6977021
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of data-processing techniques for the improvement of contrast in SPECT liver tomograms.
    Webb S
    Phys Med Biol; 1985 Oct; 30(10):1077-86. PubMed ID: 3877942
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A scan artifact caused by a band of scattered photons.
    Ryo UY; Wilczak DJ; Kim I; Pinsky SM
    Radiology; 1983 Mar; 146(3):840-1. PubMed ID: 6338559
    [No Abstract]   [Full Text] [Related]  

  • 8. Positron tomographic imaging of the liver: 68 Ga iron hydroxide colloid.
    Kumar B; Miller TR; Siegel BA; Mathias CJ; Markham J; Ehrhardt GJ; Welch MJ
    AJR Am J Roentgenol; 1981 Apr; 136(4):685-90. PubMed ID: 6784462
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Tl-201 chloride SPECT imaging of hepatocellular carcinoma.
    Kempf JS; Hudak R; Abdel-Dayem HM; Freiman H; Cheung Y
    Clin Nucl Med; 1996 Dec; 21(12):953-7. PubMed ID: 8957610
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Radiocolloid liver scintigraphy. A choice and an echo.
    Ashare AB
    Radiol Clin North Am; 1980 Aug; 18(2):315-9. PubMed ID: 7010413
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Gamma topography and computerized tomography in liver tumors].
    Gabuniia RI; Ostrovtsev IV
    Med Radiol (Mosk); 1981 Jun; 26(6):7-11. PubMed ID: 7266293
    [No Abstract]   [Full Text] [Related]  

  • 12. Detection of hepatic metastases: comparison of EOE-13 computed tomography and scintigraphy.
    Miller DL; Rosenbaum RC; Sugarbaker PH; Vermess M; Willis M; Doppman JL
    AJR Am J Roentgenol; 1983 Nov; 141(5):931-5. PubMed ID: 6312788
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Single photon emission computerized tomography (SPECT) for estimates of liver and spleen volume.
    Strauss LG; Clorius JH; Frank T; van Kaick G
    J Nucl Med; 1984 Jan; 25(1):81-5. PubMed ID: 6610031
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Diagnostic effectiveness of 99mTc-phytate colloid in the study of the hepatolienal area].
    Zubovskiĭ GA; Devishev MI; Ogneva TV; Zelentsov BA; Zuĭkova VN
    Med Radiol (Mosk); 1982 Jan; 27(1):24-8. PubMed ID: 6977079
    [No Abstract]   [Full Text] [Related]  

  • 15. Computed tomography, ultrasound, and scintigraphy of the liver in patients with colon or breast carcinoma: a prospective comparison.
    Alderson PO; Adams DF; McNeil BJ; Sanders R; Siegelman SS; Finberg HJ; Hessel SJ; Abrams HL
    Radiology; 1983 Oct; 149(1):225-30. PubMed ID: 6611929
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Comparative study of scintigraphy, single photon emission CT, and computed tomography in the evaluation of space occupying lesions of the liver].
    Dodo Y; Yamamoto K; Mukai T; Harioka T; Nakano Y; Toudou G; Tamaki N; Odori T; Hamanaka D; Torizuka K
    Nihon Igaku Hoshasen Gakkai Zasshi; 1984 Jan; 44(1):61-72. PubMed ID: 6610856
    [No Abstract]   [Full Text] [Related]  

  • 17. Improved SPECT quantification using compensation for scattered photons.
    Jaszczak RJ; Greer KL; Floyd CE; Harris CC; Coleman RE
    J Nucl Med; 1984 Aug; 25(8):893-900. PubMed ID: 6611390
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Demonstration of bone tracer uptake by liver metastases from colon carcinoma by planar and SPECT imaging.
    Siddiqui AR; Wellman HN
    Clin Nucl Med; 1984 Feb; 9(2):107-8. PubMed ID: 6232033
    [No Abstract]   [Full Text] [Related]  

  • 19. Definition of hepatic tumor microcirculation by single photon emission computerized tomography (SPECT).
    Gyves JW; Ziessman HA; Ensminger WD; Thrall JH; Niederhuber JE; Keyes JW; Walker S
    J Nucl Med; 1984 Sep; 25(9):972-7. PubMed ID: 6088735
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Special characteristics and potential of single photon emission computed tomography in the brain.
    Cowan RJ; Watson NE
    Semin Nucl Med; 1980 Oct; 10(4):335-44. PubMed ID: 6999624
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.