These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 6611259)

  • 21. [Graft patency and myocardial viability after aorto-coronary bypass surgery evaluated by exercise 201T1 myocardial SPECT].
    Yada T; Futagami Y; Koyama T; Iwata J; Konishi T; Hamada M; Nakano T; Takezawa H; Yuasa H; Kusagawa M
    J Cardiol; 1988 Jun; 18(2):299-306. PubMed ID: 3266878
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Coronary flow reserve evaluated by 201Tl myocardial perfusion SPECT after coronary artery bypass grafting (CABG) for angina pectoris].
    Ishino Y; Nakata H
    Kaku Igaku; 2000 Nov; 37(6):621-9. PubMed ID: 11193447
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Segmental quantitative analysis of digital thallium-201 myocardial scintigrams in diagnosis of coronary artery disease. Comparison with rest and exercise electrocardiography and coronary arteriography.
    Wainwrwight RJ; Maisey MN; Sowton E
    Br Heart J; 1981 Nov; 46(5):478-85. PubMed ID: 7317214
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Noninvasive assessment of coronary artery bypass patency: determination of myocardial thallium-201 washout rates.
    Zimmermann R; Tillmanns H; Knapp WH; Neumann FJ; Saggau W; Kübler W
    Eur Heart J; 1988 Mar; 9(3):319-27. PubMed ID: 3260177
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Results of quantitative myocardial scintigraphy with thallium-201 at rest and after maximum exercise--critical analysis of predictive value and clinical application (author's transl)].
    Schicha H; Rentrop P; Facorro L; Karsch KR; Blanke H; Kreuzer H; Emrich D
    Z Kardiol; 1980 Jan; 69(1):31-42. PubMed ID: 7415378
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Thallium-201 myocardial perfusion scintigrams in the evaluation of aorto-coronary saphenous bypass surgery.
    Verani MS; Marcus ML; Spoto G; Rossi NP; Ehrhardt JC; Razzak MA
    J Nucl Med; 1978 Jul; 19(7):765-72. PubMed ID: 307053
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Clinical value of thallium-201 myocardial scintigraphy with dipyridamole performed before and after aortocoronary bypass].
    Wolff F; Demangeat JL; Chambron J; Sacrez A
    Arch Mal Coeur Vaiss; 1985 Aug; 78(8):1198-204. PubMed ID: 3935077
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Analysis using scintigraphy with thallium-201 of the perfusion picture before and after myocardial revascularization].
    Astorri E; Fesani F; Busi M; Ugolotti G
    Cardiologia; 1989 Aug; 34(8):701-6. PubMed ID: 2605581
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Value of stress thallium-201 emission tomography for predicting improvement after coronary bypass grafting and assessing graft patency.
    Kureshi SA; Tamaki N; Yonekura Y; Koide H; Konishi Y; Ban T; Konishi J; Torizuka K
    Jpn Heart J; 1989 May; 30(3):287-99. PubMed ID: 2795869
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Evaluation of the post-coronary artery bypass patient by myocardial perfusion scintigraphy and computed tomography.
    Engelstad BL; Wagner S; Herfkens R; Botvinick E; Brundage B; Lipton M
    AJR Am J Roentgenol; 1983 Sep; 141(3):507-12. PubMed ID: 6603759
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Use of thallium-201 redistribution scintigraphy in the preoperative differentiation of reversible and nonreversible myocardial asynergy.
    Rozanski A; Berman DS; Gray R; Levy R; Raymond M; Maddahi J; Pantaleo N; Waxman AD; Swan HJ; Matloff J
    Circulation; 1981 Nov; 64(5):936-44. PubMed ID: 6974614
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Myocardial perfusion as an indicator of graft patency after coronary artery bypass surgery.
    Kolibash AJ; Call TD; Bush CA; Tetalman MR; Lewis RP
    Circulation; 1980 May; 61(5):882-7. PubMed ID: 6965901
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [The value of thallium myocardial scintigraphy (single photon emission computerized tomography, SPECT) for diagnosis of ischemia after myocardial infarct].
    Fries P; Thimme W; Haubold R
    Med Klin (Munich); 1994 Nov; 89(11):582-6. PubMed ID: 7815985
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Significance of perfusion studies in the detection of transient myocardial ischemia.
    Beller GA; Watson DD; Gibson RS
    Can J Cardiol; 1986 Jul; Suppl A():113A-120A. PubMed ID: 3756576
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Long-term blood flow potentials in sequential internal mammary artery grafts. Exercise thallium scan for myocardial perfusion study.
    Harjula AL; Aarnio P; Heikkilä L; Virtanen K; Mattila S
    Scand J Thorac Cardiovasc Surg; 1992; 26(2):101-5. PubMed ID: 1439638
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The inconsistent pattern of thallium defects: a clue to the false positive perfusion scintigram.
    Dunn RF; Wolff L; Wagner S; Botvinick EH
    Am J Cardiol; 1981 Aug; 48(2):224-32. PubMed ID: 7270432
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Adenosine thallium-201 tomography in evaluation of graft patency late after coronary artery bypass graft surgery.
    Khoury AF; Rivera JM; Mahmarian JJ; Verani MS
    J Am Coll Cardiol; 1997 May; 29(6):1290-5. PubMed ID: 9137226
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Myocardial imaging with thallium-201 at rest and during exercise. Comparison with coronary arteriography and resting and stress electrocardiography.
    Ritchie JL; Trobaugh GB; Hamilton GW; Gould KL; Narahara KA; Murray JA; Williams DL
    Circulation; 1977 Jul; 56(1):66-71. PubMed ID: 862173
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Simultaneous measurement of left ventricular function and myocardial perfusion during a single exercise test: dual isotope imaging with gold-195 m and thallium-201.
    Lahiri A; Zanelli GD; O'Hara MJ; Bowles MJ; Jones RI; Cave AP; Raftery EB
    Eur Heart J; 1986 Jun; 7(6):493-500. PubMed ID: 3732298
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of two radionuclide techniques for detecting disease of right and left coronary arteries.
    Johnson LL; Cabot CF; McCarthy DM; Sciacca RR; Rudin BR; Blood DK; Cannon PJ
    Herz; 1981 Jun; 6(3):166-77. PubMed ID: 7250889
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.