These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 6615999)

  • 1. Metal allergy, metal implants and fracture healing.
    Brown SA; Devine SD; Merritt K
    Biomater Med Devices Artif Organs; 1983; 11(1):73-81. PubMed ID: 6615999
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Elastic stable intramedullary nailing (ESIN) in paediatric femur and tibia shaft fractures: Comparison between titanium and stainless steel nails.
    Marengo L; Nasto LA; Michelis MB; Boero S
    Injury; 2018 Nov; 49 Suppl 3():S8-S11. PubMed ID: 30415674
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Is fracture healing in the presence of biocompatible implant materials tantalum and niobium different in comparison to steel implants?].
    Rabenseifner L; Küsswetter W; Wünsch PH; Schwab M
    Z Orthop Ihre Grenzgeb; 1984; 122(3):349-55. PubMed ID: 6475226
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The influence of different degrees of stiffness of fixation plates on experimental bone healing.
    Terjesen T; Apalset K
    J Orthop Res; 1988; 6(2):293-9. PubMed ID: 3343634
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Metal sensitivity in patients treated for tibial fractures with plates of stainless steel.
    Cramers M; Lucht U
    Acta Orthop Scand; 1977; 48(3):245-9. PubMed ID: 920115
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Coronary stent restenosis and the association with allergy to metal content of 316L stainless steel.
    Slodownik D; Danenberg C; Merkin D; Swaid F; Moshe S; Ingber A; Lotan H; Durst R
    Cardiovasc J Afr; 2018 Jan/Feb 23; 29(1):43-45. PubMed ID: 29443350
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Correlation between metal allergy and treatment outcomes after ankle fracture fixation.
    So S; Harris IA; Naylor JM; Adie S; Mittal R
    J Orthop Surg (Hong Kong); 2011 Dec; 19(3):309-13. PubMed ID: 22184160
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Chronic staphylococcal osteomyelitis: an experimental model.
    Andriole VT; Nagel DA; Southwick WO
    Yale J Biol Med; 1974 Mar; 47(1):33-9. PubMed ID: 4274843
    [No Abstract]   [Full Text] [Related]  

  • 9. Biomechanical compatibility of high strength nickel free stainless steel bone plate under lightweight design.
    Ren Y; Zhao H; Yang K; Zhang Y
    Mater Sci Eng C Mater Biol Appl; 2019 Aug; 101():415-422. PubMed ID: 31029335
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The biocompatibility of materials for internal fixation of fractures.
    Brown SA; Mayor MB
    J Biomed Mater Res; 1978 Jan; 12(1):67-82. PubMed ID: 632318
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of stainless steel and titanium low-contact dynamic compression plate application on the vascularity and mechanical properties of cortical bone after fracture.
    Jain R; Podworny N; Hearn T; Anderson GI; Schemitsch EH
    J Orthop Trauma; 1997 Oct; 11(7):490-5. PubMed ID: 9334950
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Selective versus routine patch metal allergy testing to select bar material for the Nuss procedure in 932 patients over 10years.
    Obermeyer RJ; Gaffar S; Kelly RE; Kuhn MA; Frantz FW; McGuire MM; Paulson JF; Kelly CS
    J Pediatr Surg; 2018 Feb; 53(2):260-264. PubMed ID: 29223667
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fracture healing after reamed and unreamed intramedullary nailing in sheep tibia.
    Högel F; Schlegel U; Südkamp N; Müller C
    Injury; 2011 Jul; 42(7):667-74. PubMed ID: 21074768
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development of small diameter intramedullary nails made from ISO 5832-9 stainless steel.
    Ingman AM
    Aust N Z J Surg; 2000 Mar; 70(3):221-5. PubMed ID: 10765908
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Increased corrosion of stainless steel implants in infected plated fractures.
    Hierholzer S; Hierholzer G; Sauer KH; Paterson RS
    Arch Orthop Trauma Surg (1978); 1984; 102(3):198-200. PubMed ID: 6703879
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Bone healing after metal plate fixation and external fixation of the osteotomized rabbit tibia.
    Terjesen T
    Acta Orthop Scand; 1984 Feb; 55(1):69-77. PubMed ID: 6702434
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Systemic hypersensitivity reaction to endovascular stainless steel stent.
    Univers J; Long C; Tonks SA; Freeman MB
    J Vasc Surg; 2018 Feb; 67(2):615-617. PubMed ID: 29248243
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Chitosan pin fixation of rabbit proximal tibia osteotomy].
    Zhang J; Tang J; Xu B; Cai K; Ma W; Fang Y; Shi T; Wei J
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 1998 Jun; 15(2):179-82, 185. PubMed ID: 12548910
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development of an interlocked nail for segmental defects in the rabbit tibia.
    LeCronier DJ; Papakonstantinou JS; Gheevarughese V; Beran CD; Walter NE; Atkinson PJ
    Proc Inst Mech Eng H; 2012 Apr; 226(4):330-6. PubMed ID: 22611873
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Treatment of distal tibia metaphyseal fractures; plating versus intramedullary nailing: a systematic review of recent evidence.
    Iqbal HJ; Pidikiti P
    Foot Ankle Surg; 2013 Sep; 19(3):143-7. PubMed ID: 23830160
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.