BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

98 related articles for article (PubMed ID: 6618826)

  • 21. Computer-based methods for measuring joint space and estimating erosion volume in the finger and wrist joints of patients with rheumatoid arthritis.
    Sharp JT; Gardner JC; Bennett EM
    Arthritis Rheum; 2000 Jun; 43(6):1378-86. PubMed ID: 10857798
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Quality of film-based and digital panoramic radiography.
    Molander B; Gröndahl HG; Ekestubbe A
    Dentomaxillofac Radiol; 2004 Jan; 33(1):32-6. PubMed ID: 15140820
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Selenium radiography versus storage phosphor and conventional radiography in the detection of simulated chest lesions.
    Schaefer-Prokop CM; Prokop M; Schmidt A; Neitzel U; Galanski M
    Radiology; 1996 Oct; 201(1):45-50. PubMed ID: 8816519
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A comparison of the diagnostic utility of two image receptors for panoramic radiography.
    Carmichael FA; Hirschmann PN; Scaife B; Sheard L; Mackenzie A
    Dentomaxillofac Radiol; 2000 Jan; 29(1):57-60. PubMed ID: 10654038
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Phantom study of chest radiography with storage phosphor, selenium, and film-screen systems.
    Kehler M; Lyttkens K; Andersson B; Hochbergs P; Lindberg CG; Medin J; Nordström AJ; Sanfridsson J; Vojciechowski J
    Acta Radiol; 1996 May; 37(3 Pt 1):332-6. PubMed ID: 8845264
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Modified inverse square sensitometry for the determination of the characteristic curve of radiographic screen/film systems.
    Yoshida A; Hiraki Y; Ohkawa Y; Yamada T; Hashimoto K; Aono K
    Acta Med Okayama; 1986 Feb; 40(1):33-8. PubMed ID: 3962729
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Relative speeds of Kodak computed radiography phosphors and screen-film systems.
    Huda W; Rill LN; Bruner AP
    Med Phys; 1997 Oct; 24(10):1621-8. PubMed ID: 9350716
    [TBL] [Abstract][Full Text] [Related]  

  • 28. High-speed, single-screen/single-emulsion film systems: basic imaging properties and preliminary clinical applications.
    Higashida Y; Frank PH; Doi K
    Radiology; 1983 Nov; 149(2):571-7. PubMed ID: 6622705
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Sharpness of detail and density in film-screen systems].
    Maurer HJ; Goos F
    Rontgenblatter; 1986 Sep; 39(9):260-3. PubMed ID: 3775203
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Portable chest imaging: comparison of storage phosphor digital, asymmetric screen-film, and conventional screen-film systems.
    Niklason LT; Chan HP; Cascade PN; Chang CL; Chee PW; Mathews JF
    Radiology; 1993 Feb; 186(2):387-93. PubMed ID: 8421740
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [High intensification film-screen systems in thoracic diagnosis. A clinical comparative study].
    Schäfer CB; Sokiranski R; Claussen CD
    Aktuelle Radiol; 1995 Nov; 5(6):389-93. PubMed ID: 8580141
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Information yield: a comparison of Kodak T-Mat G, Ortho L and RP X-Omat films.
    Miles DA; Van Dis ML; Peterson MG
    Dentomaxillofac Radiol; 1989 Feb; 18(1):15-8. PubMed ID: 2599233
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comparison of two screen-film combinations in contact and magnification mammography: detectability of microcalcifications.
    Oestmann JW; Kopans DB; Linetsky L; Hall DA; McCarthy KA; White G; Swann C; Kelley JE; Johnson LL
    Radiology; 1988 Sep; 168(3):657-9. PubMed ID: 3406394
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Storage phosphor versus screen-film radiography: effect of varying exposure parameters and unsharp mask filtering on the detectability of cortical bone defects.
    Prokop M; Galanski M; Oestmann JW; von Falkenhausen U; Rosenthal H; Reimer P; Nischelsky J; Reichelt S
    Radiology; 1990 Oct; 177(1):109-13. PubMed ID: 2399307
    [TBL] [Abstract][Full Text] [Related]  

  • 35. ROC and contrast detail image evaluation tests compared.
    Kelsey CA; Moseley RD; Garcia JF; Mettler FA; Parker TW; Juhl JH
    Radiology; 1985 Mar; 154(3):629-31. PubMed ID: 3969463
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Proximal surface caries detection with direct-exposure and rare earth screen/film imaging.
    Lundeen RC; McDavid WD; Barnwell GM
    Oral Surg Oral Med Oral Pathol; 1988 Dec; 66(6):734-45. PubMed ID: 3205558
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Microfocal radiographic examination of erosions in the wrist and hand of patients with rheumatoid arthritis.
    Buckland-Wright JC
    Ann Rheum Dis; 1984 Apr; 43(2):160-71. PubMed ID: 6712290
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Quantitative evaluation of film-screen combinations for x-ray diagnosis].
    Bronder T; Heinze-Assmann R
    Phys Med Biol; 1988 May; 33(5):529-39. PubMed ID: 3399512
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Evaluation of radiographic image quality parameters obtained with the REX simulator.
    Magalhaes LA; Drexler GG; deAlmeida CE
    Radiat Prot Dosimetry; 2011 Nov; 147(4):614-8. PubMed ID: 21273198
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A clinical comparison of image quality and patient exposure reduction in panoramic radiography with heavy metal filtration.
    Kapa SF; Tyndall DA
    Oral Surg Oral Med Oral Pathol; 1989 Jun; 67(6):750-9. PubMed ID: 2740096
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.