These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 6618952)

  • 21. The use of inductive plethysmography in the study of the ventilatory effects of respirator wear.
    Stark GP; Hodous TK; Hankinson JL
    Am Ind Hyg Assoc J; 1988 Aug; 49(8):401-8. PubMed ID: 3177218
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Evaluation of respiratory inductive plethysmography in infants weighing less than 1,500 grams.
    Wilkes DL; Revow M; Bryan MH; England SJ
    Am Rev Respir Dis; 1987 Aug; 136(2):416-9. PubMed ID: 3619201
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Calibration of respiratory inductive plethysmography in lambs receiving intermittent mandatory mechanical ventilation.
    Warren RH; Alderson SH
    Crit Care Med; 1988 Feb; 16(2):161-4. PubMed ID: 3277774
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Accuracy of the respiratory inductive plethysmograph during loaded breathing.
    Tobin MJ; Guenther SM; Perez W; Mador MJ
    J Appl Physiol (1985); 1987 Feb; 62(2):497-505. PubMed ID: 3558209
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Occlusion maneuver to detect the relative contribution of the rib cage and abdomen to tidal volume using respiratory inductive plethysmography in infants.
    Gagliardi L; Rusconi F; Aston H; Silverman M
    Pediatr Pulmonol; 1996 Feb; 21(2):132-7. PubMed ID: 8882215
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Accuracy of respiratory inductive plethysmograph over wide range of rib cage and abdominal compartmental contributions to tidal volume in normal subjects and in patients with chronic obstructive pulmonary disease.
    Gonzalez H; Haller B; Watson HL; Sackner MA
    Am Rev Respir Dis; 1984 Aug; 130(2):171-4. PubMed ID: 6465670
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Respiratory induction plethysmography (Respitrace): an evaluation of its use in the infant.
    Duffty P; Spriet L; Bryan MH; Bryan AC
    Am Rev Respir Dis; 1981 May; 123(5):542-6. PubMed ID: 7235376
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Scope of linear estimators of tidal and occluded volumes using thoracoabdominal indications of breathing movement coordination.
    Millard RK; Black AM
    Med Eng Phys; 2004 Apr; 26(3):225-35. PubMed ID: 14984844
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Calibration of computer-assisted (Respicomp) respiratory inductive plethysmography in newborns.
    Warren RH; Alderson SH
    Am Rev Respir Dis; 1985 Apr; 131(4):564-7. PubMed ID: 3838868
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Accuracy and consistency of respiratory inductive plethysmography for overnight tidal volume measurement.
    Zhang J; Ruch EW; Bloch KE
    J Tongji Med Univ; 2001; 21(1):35-7, 58. PubMed ID: 11523243
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Limitations of applicability of current calibration procedures for respiratory inductive plethysmography.
    Bellia V; Romano S; Sanci S; Bonsignore G
    Bull Eur Physiopathol Respir; 1984; 20(4):341-6. PubMed ID: 6478090
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Postural changes in rib cage and abdominal volume-motion coefficients and their effect on the calibration of a respiratory inductance plethysmograph.
    Zimmerman PV; Connellan SJ; Middleton HC; Tabona MV; Goldman MD; Pride N
    Am Rev Respir Dis; 1983 Feb; 127(2):209-14. PubMed ID: 6830037
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comparison of a priori calibration models for respiratory inductance plethysmography during running.
    Leutheuser H; Heyde C; Gollhofer A; Eskofier BM
    Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():6393-6. PubMed ID: 25571459
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Monitoring of ventilation during exercise by a portable respiratory inductive plethysmograph.
    Clarenbach CF; Senn O; Brack T; Kohler M; Bloch KE
    Chest; 2005 Sep; 128(3):1282-90. PubMed ID: 16162719
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Inductive plethysmography--a facilitated postural calibration technique for rapid and accurate tidal volume determination in low birth weight premature newborns.
    Stefano JL; Spitzer AR; Baumgart S; Davis JM; Fox WW
    Am Rev Respir Dis; 1986 Nov; 134(5):1020-4. PubMed ID: 3777664
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Evaluation of respiratory inductive plethysmography: accuracy for analysis of respiratory waveforms.
    Carry PY; Baconnier P; Eberhard A; Cotte P; Benchetrit G
    Chest; 1997 Apr; 111(4):910-5. PubMed ID: 9106568
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Respiratory inductance plethysmography: calibration techniques, their validation and the effects of posture.
    Stradling JR; Chadwick GA; Quirk C; Phillips T
    Bull Eur Physiopathol Respir; 1985; 21(4):317-24. PubMed ID: 4041657
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A method for measuring the CO2 dead space volume in facial visors and respiratory protective devices in human subjects.
    Strömberg T; Eklund J; Gustafsson PM
    Ergonomics; 1996 Sep; 39(9):1087-106. PubMed ID: 8681931
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Inductive plethysmography components analysis and improved non-invasive postoperative apnoea monitoring.
    Millard RK
    Physiol Meas; 1999 May; 20(2):175-86. PubMed ID: 10390020
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A wearable respiration monitoring system based on digital respiratory inductive plethysmography.
    Wu D; Wang L; Zhang YT; Huang BY; Wang B; Lin SJ; Xu XW
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():4844-7. PubMed ID: 19963862
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.