282 related articles for article (PubMed ID: 6625344)
1. Legionella pneumophila contamination of a hospital humidifier. Demonstration of aerosol transmission and subsequent subclinical infection in exposed guinea pigs.
Zuravleff JJ; Yu VL; Shonnard JW; Rihs JD; Best M
Am Rev Respir Dis; 1983 Oct; 128(4):657-61. PubMed ID: 6625344
[TBL] [Abstract][Full Text] [Related]
2. Legionella pneumonia in guinea pigs exposed to aerosols of concentrated potable water from a hospital with nosocomial Legionnaires' disease.
Meenhorst PL; Reingold AL; Gorman GW; Feeley JC; van Cronenburg BJ; Meyer CL; van Furth R
J Infect Dis; 1983 Jan; 147(1):129-32. PubMed ID: 6822749
[TBL] [Abstract][Full Text] [Related]
3. Isolation of Legionella pneumophila from hospital shower heads.
Cordes LG; Wiesenthal AM; Gorman GW; Phair JP; Sommers HM; Brown A; Yu VL; Magnussen MH; Meyer RD; Wolf JS; Shands KN; Fraser DW
Ann Intern Med; 1981 Feb; 94(2):195-7. PubMed ID: 7469211
[TBL] [Abstract][Full Text] [Related]
4. Potential in-hospital modes of transmission of Legionella pneumophila. Demonstration experiments for dissemination by showers, humidifiers, and rinsing of ventilation bag apparatus.
Woo AH; Yu VL; Goetz A
Am J Med; 1986 Apr; 80(4):567-73. PubMed ID: 3457525
[TBL] [Abstract][Full Text] [Related]
5. Legionnaires' pneumonia after aerosol exposure in guinea pigs and rats.
Davis GS; Winn WC; Gump DW; Craighead JE; Beaty HN
Am Rev Respir Dis; 1982 Dec; 126(6):1050-7. PubMed ID: 6983846
[TBL] [Abstract][Full Text] [Related]
6. Epidemiologic assessment of methods of transmission of legionellosis.
Broome CV
Zentralbl Bakteriol Mikrobiol Hyg A Med Mikrobiol Infekt Parasitol; 1983 Jul; 255(1):52-7. PubMed ID: 6637235
[TBL] [Abstract][Full Text] [Related]
7. [Legionella pneumophila pneumonia associated with the use of a home humidifier in an immunocompetent girl].
Bonilla Escobar BA; Montero Rubio JC; Martínez Juárez G
Med Clin (Barc); 2014 Jan; 142(2):70-2. PubMed ID: 24022027
[TBL] [Abstract][Full Text] [Related]
8. Experimental transmission of legionnaires' disease by exposure to aerosols of Legionella pneumophila.
Baskerville A; Fitzgeorge RB; Broster M; Hambleton P; Dennis PJ
Lancet; 1981 Dec 19-26; 2(8260-61):1389-90. PubMed ID: 6118761
[TBL] [Abstract][Full Text] [Related]
9. Another source of aerosol causing nosocomial Legionnaires' disease.
Kaan JA; Simoons-Smit AM; MacLaren DM
J Infect; 1985 Sep; 11(2):145-8. PubMed ID: 4056449
[TBL] [Abstract][Full Text] [Related]
10. Nosocomial legionella pneumonia: demonstration of potable water as the source of infection.
Ruf B; Schürmann D; Horbach I; Seidel K; Pohle HD
Epidemiol Infect; 1988 Dec; 101(3):647-54. PubMed ID: 3215293
[TBL] [Abstract][Full Text] [Related]
11. Pontiac fever: isolation of the etiologic agent (Legionella pneumophilia) and demonstration of its mode of transmission.
Kaufmann AF; McDade JE; Patton CM; Bennett JV; Skaliy P; Feeley JC; Anderson DC; Potter ME; Newhouse VF; Gregg MB; Brachman PS
Am J Epidemiol; 1981 Sep; 114(3):337-47. PubMed ID: 7304569
[TBL] [Abstract][Full Text] [Related]
12. Legionella anisa, a possible indicator of water contamination by Legionella pneumophila.
van der Mee-Marquet N; Domelier AS; Arnault L; Bloc D; Laudat P; Hartemann P; Quentin R
J Clin Microbiol; 2006 Jan; 44(1):56-9. PubMed ID: 16390948
[TBL] [Abstract][Full Text] [Related]
13. Mode of transmission of Legionella pneumophila. A critical review.
Muder RR; Yu VL; Woo AH
Arch Intern Med; 1986 Aug; 146(8):1607-12. PubMed ID: 3524495
[No Abstract] [Full Text] [Related]
14. Legionella pneumophila in hospital hot water cylinders.
Fischer-Hoch SP; Smith MG; Colbourne JS
Lancet; 1982 May; 1(8280):1073. PubMed ID: 6122876
[No Abstract] [Full Text] [Related]
15. Epidemiological evidence of legionellosis transmission through domestic hot water supply systems and possibilities of control.
Bornstein N; Vieilly C; Nowicki M; Paucod JC; Fleurette J
Isr J Med Sci; 1986 Sep; 22(9):655-61. PubMed ID: 3793449
[TBL] [Abstract][Full Text] [Related]
16. [The significance of tap water contaminated with Legionella pneumophila for the occurrence of Legionella pneumonia as hospital infection].
Meenhorst PL; van Cronenburg BJ; van Furth R
Ned Tijdschr Geneeskd; 1983 Feb; 127(8):327-32. PubMed ID: 6339957
[No Abstract] [Full Text] [Related]
17. Vaccination with Legionella pneumophila membranes induces cell-mediated and protective immunity in a guinea pig model of Legionnaires' disease. Protective immunity independent of the major secretory protein of Legionella pneumophila.
Blander SJ; Horwitz MA
J Clin Invest; 1991 Mar; 87(3):1054-9. PubMed ID: 1999485
[TBL] [Abstract][Full Text] [Related]
18. [Intra-amoebal development of Legionella pneumophila and the potential role of amoebae in the transmission of Legionnaires' disease].
Philippe C; Blech MF; Hartemann P
Med Mal Infect; 2006 Apr; 36(4):196-200. PubMed ID: 16459041
[TBL] [Abstract][Full Text] [Related]
19. [Indoor climate control equipment. Requirements for microbiocide additives to humidifier water].
Rosskamp E; Seidel K
Schriftenr Ver Wasser Boden Lufthyg; 1993; 91():219-30. PubMed ID: 8235477
[No Abstract] [Full Text] [Related]
20. Isolation of Legionella pneumophila from water systems: methods and preliminary results.
Tobin JO; Swann RA; Bartlett CL
Br Med J (Clin Res Ed); 1981 Feb; 282(6263):515-7. PubMed ID: 6780104
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]