172 related articles for article (PubMed ID: 6636949)
21. Transcutaneous blood glucose monitoring system based on an ISFET glucose sensor and studies on diabetic patients.
Ito N; Saito A; Kayashima S; Kimura J; Kuriyama T; Nagata N; Arai T; Kikuchi M
Front Med Biol Eng; 1995; 6(4):269-80. PubMed ID: 7612502
[TBL] [Abstract][Full Text] [Related]
22. Glucose monitoring and pump data management software operated on a personal digital assistant can contribute to improve diabetes control in CSII-treated patients.
Boizel R; Benhamou PY; Renard E;
Diabetes Metab; 2007 Sep; 33(4):314-5. PubMed ID: 17475533
[No Abstract] [Full Text] [Related]
23. [The development of glucose sensor sensing hydrogen peroxide by polarographic electrode with immobilized glucose oxidase -- Application to the artificial endocrine pancreas (author's transl)].
Kawamori R; Shichiri M; Nomura M; Abe H; Okuyama T; Yoshida M
Iyodenshi To Seitai Kogaku; 1980 Oct; 18(6):420-5. PubMed ID: 7024600
[No Abstract] [Full Text] [Related]
24. Continuous blood glucose monitoring: a preview.
Saudek CD
Diabet Med; 1984 Sep; 1(3):222-4. PubMed ID: 6242802
[No Abstract] [Full Text] [Related]
25. [Rapid determination of blood glucose with reagent strips in the hospital: a reliable alternative?].
Brenet R; Campodónico M; Marchetti R; Rossi G
Rev Med Chil; 1987 Oct; 115(10):960-6. PubMed ID: 3506256
[No Abstract] [Full Text] [Related]
26. Enzymatic glucose sensors. Improved long-term performance in vitro and in vivo.
Updike SJ; Shults MC; Rhodes RK; Gilligan BJ; Luebow JO; von Heimburg D
ASAIO J; 1994; 40(2):157-63. PubMed ID: 8003752
[TBL] [Abstract][Full Text] [Related]
27. Continuous glucose monitoring in interstitial fluid using glucose oxidase-based sensor compared to established blood glucose measurement in rats.
Woderer S; Henninger N; Garthe CD; Kloetzer HM; Hajnsek M; Kamecke U; Gretz N; Kraenzlin B; Pill J
Anal Chim Acta; 2007 Jan; 581(1):7-12. PubMed ID: 17386418
[TBL] [Abstract][Full Text] [Related]
28. The promise of real-time continuous glucose sensors.
Dis Manag Advis; 2006 Oct; 12(10):109-12. PubMed ID: 17133874
[No Abstract] [Full Text] [Related]
29. [Serum glucose determination with the Reflomat System, based on a new principle of measurement (author's transl)].
Sasaki A; Yamabe M; Horiuchi N
Rinsho Byori; 1978; 26(3):269-73. PubMed ID: 650958
[No Abstract] [Full Text] [Related]
30. Blood glucose assay using the glucose oxidase method in infants aged 1-24 months to determine normal glycemic values.
Stateva S
Nauchni Tr Vissh Med Inst Sofiia; 1966; 45(5):17-23. PubMed ID: 4228988
[No Abstract] [Full Text] [Related]
31. Analysis of tear fluid by CE/LIF: a noninvasive approach for glucose monitoring.
Chen R; Jin Z; Colón LA
J Capillary Electrophor; 1996; 3(5):243-8. PubMed ID: 9384729
[TBL] [Abstract][Full Text] [Related]
32. [Determination of blood sugar using the GOD Perid method].
Deuser KH; Sitzmann FC
Med Klin; 1972 Oct; 67(43):1406-9. PubMed ID: 4641923
[No Abstract] [Full Text] [Related]
33. Accuracy and utility of a 10-test disk blood glucose meter.
Kendall DM; Kaplan RA; Paulson CF; Parkes JL; Tideman AM
Diabetes Res Clin Pract; 2005 Jan; 67(1):29-35. PubMed ID: 15620431
[TBL] [Abstract][Full Text] [Related]
34. Methodology and clinical application of continuous in vivo glucose analyses [proceedings].
Trendelenburg C
J Clin Chem Clin Biochem; 1977 Jan; 15(1):31-8. PubMed ID: 839162
[No Abstract] [Full Text] [Related]
35. [Home self-monitoring of blood glucose with a new reflectance photometer].
Carlini M; Castellazzi R; Gamba Ansaldi S; Grassi G; Bruni B
Ann Osp Maria Vittoria Torino; 1982; 25(7-12):226-34. PubMed ID: 7187855
[TBL] [Abstract][Full Text] [Related]
36. [Use of an enzyme electrode with immobilized glucose oxidase in the fluid system for the determination of glucose in body fluids].
Bertermann K; Scheller F; Pfeiffer D; Jänchen M; Lutter J
Z Med Lab Diagn; 1981; 22(2):83-8. PubMed ID: 7281875
[No Abstract] [Full Text] [Related]
37. Comparison of 5 reflectance meters for capillary blood glucose determination.
Kolopp M; Louis J; Pointel JP; Kohler F; Drouin P; Debry G
Diabete Metab; 1983 Mar; 9(1):19-25. PubMed ID: 6852336
[TBL] [Abstract][Full Text] [Related]
38. Glucose oxidase method for continuous automated blood glucose determination.
Rosevear JW; Pfaff KJ; Service FJ; Molnar GD; Ackerman E
Clin Chem; 1969 Aug; 15(8):680-98. PubMed ID: 5808451
[No Abstract] [Full Text] [Related]
39. [Carrying an Accu-Chek kit: the role of the nurse in education in diabetology].
Gilbert EA
Soins; 2006 Dec; (711):56-7. PubMed ID: 17274424
[No Abstract] [Full Text] [Related]
40. New "plasma referenced" POCT glucose monitoring systems--are they suitable for glucose monitoring and diagnosis of diabetes?
Savoca R; Jaworek B; Huber AR
Clin Chim Acta; 2006 Oct; 372(1-2):199-201. PubMed ID: 16697360
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]