These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Oxygen pressure sensor shutoff valve failure in the Ohio "Wedge" anesthesia machine. Jones DE; Watson CB; Goetter C Anesthesiology; 1984 Nov; 61(5):634-5. PubMed ID: 6497020 [No Abstract] [Full Text] [Related]
6. Intermittent oxygen delivery in an Ohmeda Unitrol anesthesia machine due to a faulty O-ring check valve assembly. Varga DA; Guttery JS; Grundy BL Anesth Analg; 1987 Nov; 66(11):1200-1. PubMed ID: 3662073 [No Abstract] [Full Text] [Related]
7. [Failure of operating room oxygen delivery due to a structural defect in the ceiling column]. Sugiuchi N; Miyazato K; Hara K; Horiguchi T; Shinozaki K; Aoki T Masui; 2000 Oct; 49(10):1165-8. PubMed ID: 11075573 [TBL] [Abstract][Full Text] [Related]
8. Oxygen warning device connected directly to the oxygen cylinder. Cooke M; Waine TE Anaesthesia; 1967 Jul; 22(3):487-8. PubMed ID: 4951600 [No Abstract] [Full Text] [Related]
9. Cylinders with unmixed helium/oxygen. Health Devices; 1990 Apr; 19(4):146. PubMed ID: 2323939 [No Abstract] [Full Text] [Related]
10. Failure of a nitrous oxide-oxygen proportioning device. Richards C Anesthesiology; 1989 Dec; 71(6):997-8. PubMed ID: 2589691 [No Abstract] [Full Text] [Related]
11. Low pressure leakage in anaesthetic machines. Evaluation by positive and negative pressure tests. Somprakit P; Soontranan P Anaesthesia; 1996 May; 51(5):461-4. PubMed ID: 8694160 [TBL] [Abstract][Full Text] [Related]
12. [Pulmonary barotrauma during anesthesia]. Cheng YC; Tu KT Ma Zui Xue Za Zhi; 1989 Dec; 27(4):363-6. PubMed ID: 2633022 [TBL] [Abstract][Full Text] [Related]
13. Another potential failure in an oxygen delivery system. Heine JF; Adams PM Anesthesiology; 1985 Sep; 63(3):335-6. PubMed ID: 4025900 [No Abstract] [Full Text] [Related]
14. Oxygen flowmeter failure on the North American Dräger Narkomed 2a anesthesia machine. Rung GW; Schneider AJ Anesth Analg; 1986 Feb; 65(2):211-2. PubMed ID: 2935052 [No Abstract] [Full Text] [Related]
15. Failure of an emergency oxygen bypass in an anaesthetic machine due to sunburn! Girish ; Stacey M Int J Obstet Anesth; 2006 Oct; 15(4):336-7; discussion 337-8. PubMed ID: 16945519 [No Abstract] [Full Text] [Related]
17. The measurement of expired oxygen as disconnection alarm. Spooner RB Anesthesiology; 1989 Dec; 71(6):994-5. PubMed ID: 2589688 [No Abstract] [Full Text] [Related]
18. A potentially dangerous design fault in an oxygen analyser. Gordon P; Ferguson AM S Afr Med J; 1994 Sep; 84(9):633-4. PubMed ID: 7839294 [No Abstract] [Full Text] [Related]
19. Oxygen analyzers can detect disconnections. McGarrigle R; White S Anesth Analg; 1984 Apr; 63(4):464-5. PubMed ID: 6703378 [No Abstract] [Full Text] [Related]
20. Oxygen contamination of the nitrous oxide pipeline supply. Lye A; Patrick R Anaesth Intensive Care; 1999 Apr; 27(2):220. PubMed ID: 10212726 [No Abstract] [Full Text] [Related] [Next] [New Search]