These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
170 related articles for article (PubMed ID: 6639028)
1. Relationship between colonization of hospital building with Legionella pneumophila and hot water temperatures. Plouffe JF; Webster LR; Hackman B Appl Environ Microbiol; 1983 Sep; 46(3):769-70. PubMed ID: 6639028 [TBL] [Abstract][Full Text] [Related]
2. [Follow-up study of Legionella pneumophila pneumonia following the raising of the hot water temperature in a Dutch hospital]. van Ketel RJ; Rietra PJ; Zanen-Lim OG; van Keulen PH; Zanen HC Ned Tijdschr Geneeskd; 1986 Apr; 130(17):778-81. PubMed ID: 3713887 [No Abstract] [Full Text] [Related]
3. Evaluation of Totaro M; Costa AL; Frendo L; Profeti S; Casini B; Gallo A; Privitera G; Baggiani A Int J Environ Res Public Health; 2020 Sep; 17(19):. PubMed ID: 32993154 [TBL] [Abstract][Full Text] [Related]
4. Legionellaceae in the hospital water-supply. Epidemiological link with disease and evaluation of a method for control of nosocomial legionnaires' disease and Pittsburgh pneumonia. Best M; Yu VL; Stout J; Goetz A; Muder RR; Taylor F Lancet; 1983 Aug; 2(8345):307-10. PubMed ID: 6135832 [TBL] [Abstract][Full Text] [Related]
5. Reduction in Legionella pneumophila through heat flushing followed by continuous supplemental chlorination of hospital hot water. Snyder MB; Siwicki M; Wireman J; Pohlod D; Grimes M; Bowman-Riney S; Saravolatz LD J Infect Dis; 1990 Jul; 162(1):127-32. PubMed ID: 2355189 [TBL] [Abstract][Full Text] [Related]
6. Control of nosocomial Legionnaires' disease by keeping the circulating hot water temperature above 55 degrees C: experience from a 10-year surveillance programme in a district general hospital. Darelid J; Löfgren S; Malmvall BE J Hosp Infect; 2002 Mar; 50(3):213-9. PubMed ID: 11886198 [TBL] [Abstract][Full Text] [Related]
7. Moving forward in Legionella control. Udale A Health Estate; 2006 Mar; 60(3):29-31. PubMed ID: 16555541 [No Abstract] [Full Text] [Related]
8. Colonization of transplant unit water supplies with Legionella and protozoa: precautions required to reduce the risk of legionellosis. Patterson WJ; Hay J; Seal DV; McLuckie JC J Hosp Infect; 1997 Sep; 37(1):7-17. PubMed ID: 9321724 [TBL] [Abstract][Full Text] [Related]
9. How to prevent an outbreak of Legionnaires' disease. Fallon RJ J Hosp Infect; 1994 Aug; 27(4):247-56. PubMed ID: 7963467 [No Abstract] [Full Text] [Related]
10. Resolving the controversy on environmental cultures for Legionella: a modest proposal. Yu VL Infect Control Hosp Epidemiol; 1998 Dec; 19(12):893-7. PubMed ID: 9872524 [No Abstract] [Full Text] [Related]
11. Isolation of Legionella pneumophila from hospital cooling towers. Nadarajah M; Goh KT Ann Acad Med Singap; 1986 Jan; 15(1):6-8. PubMed ID: 3707035 [TBL] [Abstract][Full Text] [Related]
12. [Legionella contamination in the hospital environment: monitoring of the hot water distribution systems of three hospitals in Catania (Italy)]. Pignato S; Coniglio MA; Faro G; Cantaro P; Carini SA; Mangano G; Cunsolo R; Coco G; Giammanco G Ig Sanita Pubbl; 2006; 62(6):635-52. PubMed ID: 17256019 [TBL] [Abstract][Full Text] [Related]
13. Treatment of a Legionella pneumophila-colonized water distribution system using copper-silver ionization and continuous chlorination. Biurrun A; Caballero L; Pelaz C; León E; Gago A Infect Control Hosp Epidemiol; 1999 Jun; 20(6):426-8. PubMed ID: 10395146 [TBL] [Abstract][Full Text] [Related]
14. Efficacy of point-of-entry copper--silver ionisation system in eradicating Legionella pneumophila in a tropical tertiary care hospital: implications for hospitals contaminated with Legionella in both hot and cold water. Chen YS; Lin YE; Liu YC; Huang WK; Shih HY; Wann SR; Lee SS; Tsai HC; Li CH; Chao HL; Ke CM; Lu HH; Chang CL J Hosp Infect; 2008 Feb; 68(2):152-8. PubMed ID: 18192074 [TBL] [Abstract][Full Text] [Related]
15. Controlling Legionella in hospital water systems: experience with the superheat-and-flush method and copper-silver ionization. Stout JE; Lin YS; Goetz AM; Muder RR Infect Control Hosp Epidemiol; 1998 Dec; 19(12):911-4. PubMed ID: 9872527 [TBL] [Abstract][Full Text] [Related]
16. Persistent Legionella pneumophila colonization of a hospital water supply: efficacy of control methods and a molecular epidemiological analysis. Perola O; Kauppinen J; Kusnetsov J; Kärkkäinen UM; Lück PC; Katila ML APMIS; 2005 Jan; 113(1):45-53. PubMed ID: 15676014 [TBL] [Abstract][Full Text] [Related]
17. Sometimes getting into hot water solves a (Legionella) problem. Check WA JAMA; 1982 Dec; 248(21):2793-4. PubMed ID: 7143635 [No Abstract] [Full Text] [Related]
18. [Sanitizing a hospital hot water system contaminated with Legionella pneumophila]. Schulze-Röbbecke R; Jung KD; Pullmann H; Hundgeburth J Zentralbl Hyg Umweltmed; 1990 May; 190(1-2):84-100. PubMed ID: 2118357 [TBL] [Abstract][Full Text] [Related]
19. Controlling Legionella pneumophila in water systems at reduced hot water temperatures with copper and silver ionization. Cloutman-Green E; Barbosa VL; Jimenez D; Wong D; Dunn H; Needham B; Ciric L; Hartley JC Am J Infect Control; 2019 Jul; 47(7):761-766. PubMed ID: 30661910 [TBL] [Abstract][Full Text] [Related]