2. Treatment of intertrochanteric fractures of the femur. A comparison of the Richards screw-plate with the Jewett nail-plate. Heyse-Moore GH; MacEachern AG; Evans DC J Bone Joint Surg Br; 1983 May; 65(3):262-7. PubMed ID: 6841393 [TBL] [Abstract][Full Text] [Related]
3. Treatment of intertrochanteric fractures with a sliding nail-plate. Bonamo JJ; Accettola AB J Trauma; 1982 Mar; 22(3):205-15. PubMed ID: 7069804 [TBL] [Abstract][Full Text] [Related]
4. Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the Gamma nail and compression hip screw. Madsen JE; Naess L; Aune AK; Alho A; Ekeland A; Strømsøe K J Orthop Trauma; 1998 May; 12(4):241-8. PubMed ID: 9619458 [TBL] [Abstract][Full Text] [Related]
5. Instability of trochanteric hip fractures following internal fixation. A radiographic comparison of the Richards sliding screw-plate and the McLaughlin nail-plate. Møller BN; Lucht U; Grymer F; Bartholdy NJ Acta Orthop Scand; 1984 Oct; 55(5):517-20. PubMed ID: 6507072 [TBL] [Abstract][Full Text] [Related]
6. Comparison and analysis of reoperations in two different treatment protocols for trochanteric hip fractures - postoperative technical complications with dynamic hip screw, intramedullary nail and Medoff sliding plate. Paulsson J; Stig JC; Olsson O BMC Musculoskelet Disord; 2017 Aug; 18(1):364. PubMed ID: 28836973 [TBL] [Abstract][Full Text] [Related]
7. Internal fixation of intertrochanteric hip fractures: a clinical and biomechanical study. Jacobs RR; McClain O; Armstrong HJ Clin Orthop Relat Res; 1980; (146):62-70. PubMed ID: 7371270 [TBL] [Abstract][Full Text] [Related]
8. Proximal femoral fractures: a biomechanical study to compare intramedullary and extramedullary fixation. Curtis MJ; Jinnah RH; Wilson V; Cunningham BW Injury; 1994 Mar; 25(2):99-104. PubMed ID: 8138307 [TBL] [Abstract][Full Text] [Related]
9. Prospective randomized controlled trial of an intramedullary nail versus dynamic screw and plate for intertrochanteric fractures of the femur. Adams CI; Robinson CM; Court-Brown CM; McQueen MM J Orthop Trauma; 2001 Aug; 15(6):394-400. PubMed ID: 11514765 [TBL] [Abstract][Full Text] [Related]
10. Comparison of compression hip screw and gamma nail for treatment of peritrochanteric fractures. Bess RJ; Jolly SA J South Orthop Assoc; 1997; 6(3):173-9. PubMed ID: 9322196 [TBL] [Abstract][Full Text] [Related]
11. Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Parker MJ; Handoll HH Cochrane Database Syst Rev; 2008 Jul; (3):CD000093. PubMed ID: 18646058 [TBL] [Abstract][Full Text] [Related]
12. Radiographic and functional results of osteosynthesis using the proximal femoral nail antirotation (PFNA) in the treatment of unstable intertrochanteric femoral fractures. Sahin S; Ertürer E; Oztürk I; Toker S; Seçkin F; Akman S Acta Orthop Traumatol Turc; 2010; 44(2):127-34. PubMed ID: 20676015 [TBL] [Abstract][Full Text] [Related]
13. Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95 degrees screw-plate: a prospective, randomized study. Sadowski C; Lübbeke A; Saudan M; Riand N; Stern R; Hoffmeyer P J Bone Joint Surg Am; 2002 Mar; 84(3):372-81. PubMed ID: 11886906 [TBL] [Abstract][Full Text] [Related]
14. [Evaluation of impaction on bone nail and bone plate of the pertrochanteric fracture]. de la Caffinière JY; Ferrer C; Laurent A; de la Caffinière M Rev Chir Orthop Reparatrice Appar Mot; 1997; 83(3):243-50. PubMed ID: 9255360 [TBL] [Abstract][Full Text] [Related]
15. Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Parker MJ; Handoll HH Cochrane Database Syst Rev; 2005 Oct; (4):CD000093. PubMed ID: 16235272 [TBL] [Abstract][Full Text] [Related]
17. Nonunion of intertrochanteric fractures of the femur following open reduction and internal fixation. Results of second attempts to gain union. Mariani EM; Rand JA Clin Orthop Relat Res; 1987 May; (218):81-9. PubMed ID: 3568500 [TBL] [Abstract][Full Text] [Related]
18. Trochanteric fractures treated by the McLaughlin nail and plate. Paaschburg Nielsen B; Jelnes R; Rasmussen LB; Ebling A Injury; 1985 Mar; 16(5):333-6. PubMed ID: 4008014 [TBL] [Abstract][Full Text] [Related]
19. Treatment of intertrochanteric fracture of the femur using sliding screw plate fixation. Wolfgang GL; Bryant MH; O'Neill JP Clin Orthop Relat Res; 1982 Mar; (163):148-58. PubMed ID: 7067245 [TBL] [Abstract][Full Text] [Related]
20. Stability of osteosynthesis in trochanteric fractures. Comparison of three fixation devices in cadavers. Larsson S; Elloy M; Hansson LI Acta Orthop Scand; 1988 Aug; 59(4):386-90. PubMed ID: 3421074 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]