These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
103 related articles for article (PubMed ID: 6646080)
1. Acceptance testing and quality assurance of automated scanning film densitometers used in the dosimetry of electron and photon therapy beams. Holmes TW; McCullough EC Med Phys; 1983; 10(5):698-700. PubMed ID: 6646080 [TBL] [Abstract][Full Text] [Related]
2. Recommendations for clinical electron beam dosimetry: supplement to the recommendations of Task Group 25. Gerbi BJ; Antolak JA; Deibel FC; Followill DS; Herman MG; Higgins PD; Huq MS; Mihailidis DN; Yorke ED; Hogstrom KR; Khan FM Med Phys; 2009 Jul; 36(7):3239-79. PubMed ID: 19673223 [TBL] [Abstract][Full Text] [Related]
3. Evaluation of the EDR-2 film for relative dosimetry of high-energy photon and electron beams. Ahmad M; Chen Z; Song H; Deng J; Nath R Radiat Prot Dosimetry; 2006; 120(1-4):159-62. PubMed ID: 16644932 [TBL] [Abstract][Full Text] [Related]
4. GafChromic RTQA film for routine quality assurance of high-energy photon beams. Thomas MD; Warrington AP Phys Med Biol; 2006 Mar; 51(6):1439-47. PubMed ID: 16510954 [TBL] [Abstract][Full Text] [Related]
5. Quality assurance control in the EORTC cooperative group of radiotherapy. 2. Dosimetric intercomparison. Johansson KA; Horiot JC; Van Dam J; Lepinoy D; Sentenac I; Sernbo G Radiother Oncol; 1986 Nov; 7(3):269-79. PubMed ID: 3809589 [TBL] [Abstract][Full Text] [Related]
6. New developments in radiochromic film dosimetry. Soares CG Radiat Prot Dosimetry; 2006; 120(1-4):100-6. PubMed ID: 16987914 [TBL] [Abstract][Full Text] [Related]
7. Portal verification of high-energy electron beams using their photon contamination by film-cassette systems. Geyer P; Baus WW; Baumann M Strahlenther Onkol; 2006 Jan; 182(1):37-44. PubMed ID: 16404519 [TBL] [Abstract][Full Text] [Related]
8. Dosimetric performance of an enhanced dose range radiographic film for intensity-modulated radiation therapy quality assurance. Olch AJ Med Phys; 2002 Sep; 29(9):2159-68. PubMed ID: 12349938 [TBL] [Abstract][Full Text] [Related]
9. Optically stimulated luminescence (OSL) of carbon-doped aluminum oxide (Al2O3:C) for film dosimetry in radiotherapy. Schembri V; Heijmen BJ Med Phys; 2007 Jun; 34(6):2113-8. PubMed ID: 17654914 [TBL] [Abstract][Full Text] [Related]
10. Film dosimetry of clinical electron beams. van Battum LJ; Huizenga H Int J Radiat Oncol Biol Phys; 1990 Jan; 18(1):69-76. PubMed ID: 2298637 [TBL] [Abstract][Full Text] [Related]
11. Dosimetric properties of improved GafChromic films for seven different digitizers. Devic S; Seuntjens J; Hegyi G; Podgorsak EB; Soares CG; Kirov AS; Ali I; Williamson JF; Elizondo A Med Phys; 2004 Sep; 31(9):2392-401. PubMed ID: 15487718 [TBL] [Abstract][Full Text] [Related]
12. Extraction of electron beam dose parameters from EBT2 film data scored in a mini phantom. O'Reilly D; Smit CJ; du Plessis FC Australas Phys Eng Sci Med; 2013 Sep; 36(3):339-46. PubMed ID: 23794059 [TBL] [Abstract][Full Text] [Related]
13. Dosimetry of high energy photon and electron beams with CEA films. Cheng CW; Das IJ Med Phys; 1996 Jul; 23(7):1225-32. PubMed ID: 8839417 [TBL] [Abstract][Full Text] [Related]
14. A comparison of TPS and different measurement techniques in small-field electron beams. Donmez Kesen N; Cakir A; Okutan M; Bilge H Med Dosim; 2015; 40(1):9-15. PubMed ID: 25219322 [TBL] [Abstract][Full Text] [Related]
15. TG-69: radiographic film for megavoltage beam dosimetry. Pai S; Das IJ; Dempsey JF; Lam KL; Losasso TJ; Olch AJ; Palta JR; Reinstein LE; Ritt D; Wilcox EE; Med Phys; 2007 Jun; 34(6):2228-58. PubMed ID: 17654924 [TBL] [Abstract][Full Text] [Related]
16. Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance. Fuss M; Sturtewagen E; De Wagter C; Georg D Phys Med Biol; 2007 Jul; 52(14):4211-25. PubMed ID: 17664604 [TBL] [Abstract][Full Text] [Related]
17. Variations in dose distribution and optical properties of Gafchromic(TM) EBT2 film according to scanning mode. Park S; Kang SK; Cheong KH; Hwang T; Kim H; Han T; Lee MY; Kim K; Bae H; Su Kim H; Han Kim J; Jae Oh S; Suh JS Med Phys; 2012 May; 39(5):2524-35. PubMed ID: 22559623 [TBL] [Abstract][Full Text] [Related]
18. Comparison of three high-resolution digitizers for radiochromic film dosimetry. Gluckman GR; Reinstein LE Med Phys; 2002 Aug; 29(8):1839-46. PubMed ID: 12201431 [TBL] [Abstract][Full Text] [Related]
19. Evaluation of a Gafchromic EBT2 film dosimetry system for radiotherapy quality assurance. Aland T; Kairn T; Kenny J Australas Phys Eng Sci Med; 2011 Jun; 34(2):251-60. PubMed ID: 21465275 [TBL] [Abstract][Full Text] [Related]
20. Verification of IMRT fields by film dosimetry. Bucciolini M; Buonamici FB; Casati M Med Phys; 2004 Jan; 31(1):161-8. PubMed ID: 14761032 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]