These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 6648313)

  • 1. High speed tympanometry and ipsilateral middle ear reflex measurements using a computerized impedance meter. A comparison with the results obtained by a conventional impedance meter.
    Ivarsson A; Tjernström O; Bylander A; Bennrup S
    Scand Audiol; 1983; 12(3):157-63. PubMed ID: 6648313
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The acoustic impedance locus for normal human ears.
    Parson I; Kunov H; Abel SM; Alberti PW
    Scand Audiol Suppl; 1984; 22():1-14. PubMed ID: 6596702
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Objective diagnosis of otitis media in early infancy by tympanometry and ipsilateral acoustic reflex thresholds.
    Marchant CD; McMillan PM; Shurin PA; Johnson CE; Turczyk VA; Feinstein JC; Panek DM
    J Pediatr; 1986 Oct; 109(4):590-5. PubMed ID: 3761072
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Real-ear calibration of ipsilateral acoustic reflex stimuli from five types of impedance meter.
    Lutman ME
    Scand Audiol; 1980; 9(3):137-45. PubMed ID: 7444332
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Simulating reflex induced changes in the acoustic impedance of the ear.
    Sirlin MW; Levitt H
    J Commun Disord; 1991 Jun; 24(3):201-10. PubMed ID: 1939725
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A fast response impedance meter for acoustic reflex measurements.
    Stephan K
    IEEE Trans Biomed Eng; 1994 Apr; 41(4):391-3. PubMed ID: 8063306
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effects of aging on the magnitude of the acoustic reflex.
    Wilson RH
    J Speech Hear Res; 1981 Sep; 24(3):406-14. PubMed ID: 7300282
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Normal function of the middle ear and its measurement.
    Zwislocki JJ
    Audiology; 1982; 21(1):4-14. PubMed ID: 7055478
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Factors influencing the acoustic-immittance characteristics of the acoustic reflex.
    Wilson RH
    J Speech Hear Res; 1979 Sep; 22(3):480-99. PubMed ID: 502509
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Maturation of the middle and external ears: acoustic power-based responses and reflectance tympanometry.
    Keefe DH; Levi E
    Ear Hear; 1996 Oct; 17(5):361-73. PubMed ID: 8909884
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Middle ear muscle reflex measurement in neonates: comparison between 1000Hz and 226Hz probe tones.
    de Lyra-Silva KA; Sanches SG; Neves-Lobo IF; Ibidi SM; Carvallo RM
    Int J Pediatr Otorhinolaryngol; 2015 Sep; 79(9):1510-5. PubMed ID: 26210875
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Impedance audiometric study of children. Comparison of impedance tympanoscope ZS 330 with impedance audiometer ZO 73 A.
    Birch L; Elbrønd O; Kristiansen L
    Scand Audiol; 1986; 15(3):151-6. PubMed ID: 3797982
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Tympanometry in infants with middle ear effusion having been identified using spiral computerized tomography.
    Zhiqi L; Kun Y; Zhiwu H
    Am J Otolaryngol; 2010; 31(2):96-103. PubMed ID: 20015724
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Acoustic-immittance measures in normal ears.
    Wiley TL; Oviatt DL; Block MG
    J Speech Hear Res; 1987 Jun; 30(2):161-70. PubMed ID: 3599948
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Wideband reflectance tympanometry in normal adults.
    Margolis RH; Saly GL; Keefe DH
    J Acoust Soc Am; 1999 Jul; 106(1):265-80. PubMed ID: 10420621
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Simultaneous recording and averaging of middle ear muscle reflex measured by impedance and ear canal pressure (author's transl)].
    Honjo I; Matsui H; Okazaki N; Ushiro K
    Nihon Jibiinkoka Gakkai Kaiho; 1980 Nov; 83(11):1461-7. PubMed ID: 7277072
    [No Abstract]   [Full Text] [Related]  

  • 17. Phasor admittance measurements of the middle ear. II. Normal phasor tympanograms and acoustic reflexes.
    Lutman ME; McKenzie H; Swan IR
    Scand Audiol; 1984; 13(4):265-74. PubMed ID: 6523045
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of ear canal pressure on threshold and growth of the acoustic reflex.
    Ruth RA; Tucci DL; Nilo ER
    Ear Hear; 1982; 3(1):39-41. PubMed ID: 7060846
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Acoustic middle ear reflexes in laboratory animals using clinical equipment: technical considerations.
    Counter SA; Borg E; Engström B
    Audiology; 1989; 28(3):135-43. PubMed ID: 2735848
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Clinical experience with ipsilateral impedance audiometry (author's transl)].
    Chüden HG; Heid F
    Laryngol Rhinol Otol (Stuttg); 1982 Jul; 61(7):399-401. PubMed ID: 7109804
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.