These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

92 related articles for article (PubMed ID: 6649153)

  • 21. Attenuation estimation with the zero-crossing technique: phantom studies.
    Ophir J; Ghouse MA; Ferrari LA
    Ultrason Imaging; 1985 Apr; 7(2):122-32. PubMed ID: 3909600
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Tissue Attenuation Estimation by Mean Frequency Downshift and Bandwidth Limitation.
    Klimonda Z; Postema M; Nowicki A; Litniewski J
    IEEE Trans Ultrason Ferroelectr Freq Control; 2016 Aug; 63(8):1107-15. PubMed ID: 27254862
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Characterization of the ultrasonic attenuation coefficient and its frequency dependence in a polymer gel dosimeter.
    Crescenti RA; Bamber JC; Partridge M; Bush NL; Webb S
    Phys Med Biol; 2007 Nov; 52(22):6747-59. PubMed ID: 17975295
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Improvements in the spectral difference method for measuring ultrasonic attenuation.
    Insana M; Zagzebski J; Madsen E
    Ultrason Imaging; 1983 Oct; 5(4):331-45. PubMed ID: 6686899
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Ultrasonic attenuation estimation in-vivo using the difference ratio correction method.
    Zhou K; Zhang D; Lin C; Zhu S
    J Acoust Soc Am; 1992 Nov; 92(5):2532-8. PubMed ID: 1479118
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Pressure-dependent attenuation with microbubbles at low mechanical index.
    Tang MX; Eckersley RJ; Noble JA
    Ultrasound Med Biol; 2005 Mar; 31(3):377-84. PubMed ID: 15749561
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Ultrasound attenuation estimation using the LMSE filters and the median filter.
    Jang HS; Lee MH; Park SB
    Ultrasound Med Biol; 1988; 14(1):51-8. PubMed ID: 3347963
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Feasibility of A-mode ultrasound attenuation as a monitoring method of local hyperthermia treatment.
    Manaf NA; Aziz MN; Ridzuan DS; Mohamad Salim MI; Wahab AA; Lai KW; Hum YC
    Med Biol Eng Comput; 2016 Jun; 54(6):967-81. PubMed ID: 27039402
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Frequency-dependent attenuation-compensation functions for ultrasonic signals backscattered from random media.
    Oelze ML; O'Brien WD
    J Acoust Soc Am; 2002 May; 111(5 Pt 1):2308-19. PubMed ID: 12051451
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Ultrasonic attenuation and absorption in liver tissue.
    Parker KJ
    Ultrasound Med Biol; 1983; 9(4):363-9. PubMed ID: 6649154
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparison of theoretical scattering results and ultrasonic data from clinical liver examinations.
    Lizzi FL; King DL; Rorke MC; Hui J; Ostromogilsky M; Yaremko MM; Feleppa EJ; Wai P
    Ultrasound Med Biol; 1988; 14(5):377-85. PubMed ID: 3051612
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Attenuation coefficient measurement in the thyroid.
    Fujii Y; Taniguchi N; Itoh K; Omoto K
    J Ultrasound Med; 2003 Oct; 22(10):1067-73. PubMed ID: 14606563
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Method for Estimating the Acoustic Pressure in Tissues Using Low-Amplitude Measurements in Water.
    Keravnou CP; Izamis ML; Averkiou MA
    Ultrasound Med Biol; 2015 Nov; 41(11):3001-12. PubMed ID: 26320668
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Lower Bound on Estimation Variance of the Ultrasonic Attenuation Coefficient Using the Spectral-Difference Reference-phantom Method.
    Samimi K; Varghese T
    Ultrason Imaging; 2017 May; 39(3):151-171. PubMed ID: 28425388
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Improved description of shock wave evolution in media with frequency power law dependent attenuation.
    Wallace KD; Holland MR; Miller JG
    J Acoust Soc Am; 2001 May; 109(5 Pt 1):2263-5. PubMed ID: 11386578
    [No Abstract]   [Full Text] [Related]  

  • 36. Nonlinear propagation effects on broadband attenuation measurements and its implications for ultrasonic tissue characterization.
    D'hooge J; Bijnens B; Nuyts J; Gorce JM; Friboulet D; Thoen J; Van de Werf F; Suetens P
    J Acoust Soc Am; 1999 Aug; 106(2):1126-33. PubMed ID: 10462815
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effect of ultrasonic attenuation on the feasibility of acoustic tweezers.
    Lee J; Shung KK
    Ultrasound Med Biol; 2006 Oct; 32(10):1575-83. PubMed ID: 17045879
    [TBL] [Abstract][Full Text] [Related]  

  • 38. On estimating the number density of random scatterers from backscattered acoustic signals.
    Sleefe GE; Lele PP
    Ultrasound Med Biol; 1988; 14(8):709-27. PubMed ID: 3062865
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Converting computed tomography images into photon interaction coefficients by using stoichiometric calibration and parametric fit models.
    Shih CT; Wu J
    Med Phys; 2017 Feb; 44(2):510-521. PubMed ID: 28133756
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Measurement of thermal and ultrasonic properties of some biological tissues.
    El-Brawany MA; Nassiri DK; Terhaar G; Shaw A; Rivens I; Lozhken K
    J Med Eng Technol; 2009; 33(3):249-56. PubMed ID: 19340696
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.